  • Small biconical microwave antenna elements
  • 20 - 220 MHz
  • Compliant with FMC1278 + Others
  • Purchase with NMHC 4 MM
  • 30 W

The TBMR-110M EMI Analyzer is designed to carry out conducted emission measurements. Its affordability and versatility make it a perfect tool for engineers doing pre-compliance measurements during the development process.
  • True DC – 110 MHz measurement range
  • CISPR-16, ANSI and MIL-STD compliant detectors
  • Peak, Quasi-Peak, Average, CISPR Average, RMS and CISPR RMS dectectors working in parallel
  • Zero Span operation with time domain triggering
  • Linear, log amplitude and frequency display

These measuring systems are used for the optical, digital transmission of analog signals:

  • 1-16 Channels
  • With a resolution of 10 Bit
  • maximal analog bandwidth of 100 kHz.

IEC / EN 61000-4-2 The test generator SESD 230 simulates electrostatic discharge as defined in the standard IEC / EN 61000-4-2. Depend on the Equipment Under Test (EUT) and the test set-up for laboratory tests the IEC standard shows two test methods; Test voltage max. 30,0 kV AIR und CON; Discharge impedance 150pF/330 Ohm (IEC); Battery or mains operation; Predefined tests, standard and other

IEC / EN 61000-4-2 The test generator SESD 216 simulates electrostatic discharge as defined in the standard IEC / EN 61000-4-2. Depend on the Equipment Under Test (EUT) and the test set-up for laboratory tests the IEC standard shows two test methods; Air discharge (AIR) and Contact discharge (CON); Test voltage max. 16,5 kV AIR, max. 10,0 kV CON; Discharge impedance 150pF/330 Ohm (IEC); Battery or mains operation; Predefined tests - standard and other

The TBLC08 is a Line Impedance Stabilization Network for the measurement of line-conducted interference within the range of 9kHz to 30MHz, according to the CISPR16 standard. The device is designed for testing single phase, AC-powered equipment with supply voltages up to maximum 240V.

The TBOH01 5µH LISN is a device required to setup conducted noise measurements of DC-powered devices. It is designed to be used for EMC pre-testing in the frequency range of 150kHz to 110 MHz.

EM Clamp for immunity tests IEC / EN 61000-4-6 Ed. 4.0 • EM Clamp for immunity testing of cables with up to 20 (35) mm diameter • High coupling factor: less than 15 watts amplifier output power is required to obtain a test level of 10 V • Calibration unit and calibration data are supplied with each unit.

The TBLM1 LISN Mate is a companion device for LISNs, which splits the conducted noise signal into its common mode and differential mode components. The LISN Mate is connected to the output of a LISN inserted into the positive supply line and to a second LISN inserted into the negative supply line.

The TBCP1-200, TBCP1-250, and TBCP1-500 is fixed aperture RF current monitoring probe, expanding the Tekbox product range of affordable EMC pre-compliance test equipment. The probe has a 3dB bandwidth of approximately 200 MHz and is characterized and usable over the frequency range from 10kHz to 500 MHz. The aperture of the RF current monitoring probe is 25 mm. Its transfer impedance is > 14 dB Ohm in the range from 40 kHz to 200 (500) MHz.