Coil Set 4-39_9k-150k EN 61000-4-39 & RS101 9kHz - 150kHz, Tx & Rx Set

Coil Set 4-39_9k-150k EN 61000-4-39 & RS101 9kHz - 150kHz, Tx & Rx Set

Coil Set 4-39_150k-26M EN 61000-4-39, 150 kHz - 26 MHz, Tx & Rx Set

Coil Set 4-39_150k-26M EN 61000-4-39, 150 kHz - 26 MHz, Tx & Rx Set

FESP 5133-7/41 - 10 - 250 kHz Circular Screened Coil

FESP 5133-7/41 - 10 - 250 kHz Circular Screened Coil

FESP 5134-40 - 5 -250 kHz Circular Screened Coil

FESP 5134-40 - 5 -250 kHz Circular Screened Coil

FESP 5134-1 - 10 - 400 MHz Circular Screened Coil

FESP 5134-1 - 10 - 400 MHz Circular Screened Coil

Coil Set 14708-7, Test set for testing to ISO 14708-7 A/B levels

Coil Set 14708-7, Test set for testing to ISO 14708-7 A/B levels

FESP 5133-F, 10 - 200 kHz Circular Screened Coil

FESP 5133-F, 10 - 200 kHz Circular Screened Coil

Products

Coil Set 4-39_9k-150k EN 61000-4-39 & RS101 9kHz - 150kHz, Tx & Rx Set

Low-Frequency Transmit Coil (CAB4-3912)

  • Frequency: 9 kHz to 150 kHz
  • Main Diameter: 120 mm
  • Maximum Current: 15 A
  • Number of turns: 20

Low-Frequency Sense Coil (CABLSLF) 

  • Frequency: 9 kHz to 150 kHz
  • Diameter to center of the coil: 40 mm
  • Number of turns: 51
  • Wire type: 7/41 LITZ
  • Winding Type: Electrostatically shielded

Coil Set 4-39_150k-26M EN 61000-4-39, 150 kHz - 26 MHz, Tx & Rx Set

High-Frequency Transmit Coil (CAB4-3910)

  • Frequency: 150 kHz to 26 MHz
  • Main Diameter: 100 mm
  • Number of Turns: 3
  • Wire Diameter: 1mm
  • Connection type: ‘N’ type Coaxial

High-Frequency Sense Coil (CABLSHF)

 

  • Frequency: 150 kHz to 26 MHz
  • Diameter to center of the coil: 41 mm
  • Number of turns: 1
  • Wire type: 1mm single core
  • Winding Type: Electrostatically shielded

FESP 5133-7/41 - 10 - 250 kHz Circular Screened Coil

  • Magnetic field monitoring loop 
  • 10 - 250 kHz
  • Diam. 133mm
  • turns 36
  • Emissions testing

FESP 5134-40 - 5 -250 kHz Circular Screened Coil

  • Magnetic field monitoring loop 
  • 5 - 250 kHz
  • Diam. 40mm
  • turns 51
  • The level setting for Immunity testing to MIL-STD-461
  • Meets requirements of Stellantis CS.00244 2023 ELECTRICAL AND EMC PERFORMANCE REQUIREMENTS FOR E/E COMPONENTS

FESP 5134-1 - 10 - 400 MHz Circular Screened Coil

  • Magnetic field monitoring loop 
  • 10 - 400 MHz
  • Diam. 40mm
  • turns 1
  • Level setting for Immunity testing to IEC 61000-4-39

Coil Set 14708-7, Test set for testing to ISO 14708-7 A/B levels

LF Transmit Coil (CABTL16 & CABTL11)

  • Frequency: 16.6 Hz - 27MHz
  • 2 loop sets
  • Meets ISO 14708-7 Criteria A and High B levels
  • Use 100 Watt Audio amplifier up to 35kHz
  • Use 150 Watt 50Ohm amplifier 25 kHz - 27 MHz 

 

FESP 5133-F, 10 - 200 kHz Circular Screened Coil

  • Magnetic field monitoring loop 
  • 10 - 200 kHz
  • Diam. 133mm
  • turns 36
  • Emissions testing


Loading...