HAEFELY AG | NORTH AMERICAN SALES AND SUPPORT
Select a complete EMC immunity test setup with Absolute EMC: the right generator, coupling network, discharge network and accessories for your equipment under test.
HAEFELY AG manufactures EMC immunity and impulse-test equipment for laboratories, product developers and manufacturers. Founded by Emil Haefely in 1904 and based in Basel, Switzerland, the company develops equipment for electrostatic discharge, surge combination wave, electrical fast transient (EFT/burst), ring wave, telecom impulses and magnetic-field testing.
Absolute EMC distributes and supports Haefely EMC equipment across the United States, Canada and Mexico. We help North American engineers compare configurations, interpret equipment requirements and assemble systems for their application. Haefely is the equipment manufacturer; Absolute EMC provides the regional equipment-selection, quotation and support connection.
| Test requirement | Equipment to explore | What to consider |
|---|---|---|
| Surge, EFT/burst and voltage dips | Haefely AXOS 5 and Haefely AXOS 8 | Required waveforms, test voltage, licensed functions and DUT supply current. |
| ESD contact and air discharge | ONYX VISION 8, ONYX VISION 16, ONYX VISION 30 | Required voltage, discharge network, test-point documentation and upgrade path. |
| Three-phase AC or high-voltage DC transient testing | FP-COMB AC, DC and AC+DC | Supply voltage, 63/125/200 A current rating, DUT characteristics and generator compatibility. |
| Signal, data and control-line coupling | IP4B; PCD and DEC coupling/decoupling equipment | Cable type, number of lines, required coupling method and decoupling arrangement. |
| Higher-energy surge and impulse applications | PSURGE 30.2 | Impulse module, waveform, peak voltage/current and application-specific coupling. |
| Power-frequency magnetic immunity | MAG 1000 | Required field strength, exposure time, frequency and DUT dimensions. |
Haefely AXOS systems combine multiple conducted-immunity functions in one instrument. Choose the configuration that matches your present test program, then discuss available function upgrades as requirements expand. The supported functions below depend on the installed configuration and appropriate accessories.
| Selection point | AXOS 5 | AXOS 8 |
|---|---|---|
| Surge combination wave | Up to 5 kV | Up to 7 kV |
| EFT/burst | Up to 5 kV | Up to 5 kV |
| Ring wave | Select AXOS 8 when ring-wave capability is required. | Up to 7 kV with the ring-wave function. |
| Telecom wave | Select AXOS 8 for the telecom-wave configuration. | Telecom-wave capability with the appropriate function and external TW 8 module. |
| Voltage dips and interruptions | Available configurations; appropriate supply/transformer arrangement required. | Available configurations; appropriate supply/transformer arrangement required. |
| Integrated coupling network | Single-phase CDN, up to 16 A; verify applicable voltage and operating limits. | Single-phase CDN, up to 16 A; verify applicable voltage and operating limits. |
| Best starting point | Applications centered on surge, EFT/burst and dips testing. | Applications needing higher surge voltage, ring wave or telecom-wave capability. |
Typical test methods include IEC/EN 61000-4-4 for EFT/burst, IEC/EN 61000-4-5 for surge, IEC/EN 61000-4-11 for AC dips and interruptions, and IEC/EN 61000-4-29 for DC dips and interruptions. AXOS 8 configurations also address ring-wave testing under IEC/EN 61000-4-12. The selected function, coupling method and accessories determine the test coverage.

Haefely ONYX VISION ESD guns combine contact and air discharge testing with an integrated camera and color touchscreen. View the discharge location and capture images to support test-point documentation. Choose the voltage range required by your test plan; lower-voltage versions can be upgraded with a purchased unlock code.
| ESD simulator | Contact and air discharge | Selection guidance |
|---|---|---|
| ONYX VISION 8 | 1-8 kV | For test plans within 8 kV; purchased upgrades allow expansion to higher-voltage configurations. |
| ONYX VISION 16 | 1-16 kV | For test plans requiring up to 16 kV; purchased upgrade to 30 kV available. |
| ONYX VISION 30 | 1-30 kV | For test plans requiring the highest listed family voltage, up to 30 kV. |
All three versions share the camera-assisted platform. Select the RC network, discharge tips and test accessories required for your standard and procedure. A higher-rated tip or network does not raise the licensed output voltage. Review the individual model pages for included components and compatible options.
The coupling/decoupling network connects the transient generator to the DUT power circuit while helping isolate the supply from the applied disturbance. Haefely FP-COMB networks extend a suitable AXOS setup to higher-current and three-phase applications. Compare the supply type first, then choose the current rating.
| FP-COMB family | Current choices | Application |
|---|---|---|
| 690 V AC networks | 63, 125 or 200 A | Single- and three-phase AC power-circuit transient testing; see the model page for limited DC ratings. |
| 1500 V DC networks | 63, 125 or 200 A | High-voltage DC power-circuit transient testing, subject to the specified operating limits and load characteristics. |
| AC+DC configurations | 63, 125 or 200 A | DC platform with the purchased AC option for applications requiring both supply types. Review the exact terminal and voltage configuration. |
Generator settings alone do not establish DUT-side test capability. Confirm current, supply voltage, coupling mode and permitted operating conditions before selecting a network.
| Equipment | Purpose |
|---|---|
| IP4B EFT/burst capacitive coupling clamp | Capacitive application of EFT/burst disturbances to signal and data cables. |
| PCD 121 | Coupling for symmetrical data and control-line applications. |
| PCD 126A | Coupling for asymmetrical data and control-line applications. |
| DEC 5 | Decoupling equipment; select according to the line arrangement and test method. |
| DEC 6 | Decoupling equipment; verify the appropriate configuration on the product page. |
| DEC 7 | Decoupling equipment; verify the appropriate configuration on the product page. |
| PCD-1000-4 | Specialist coupling equipment; review the individual product specifications. |
Tell us the standard and edition, required test levels, DUT operating voltage/current, single- or three-phase supply, cable types and planned expansion. We can help identify the appropriate Haefely generator configuration and the networks, clamps, transformers, RC modules and other accessories needed to complete the setup.
Typical users include commercial EMC laboratories and engineering teams developing industrial, power-conversion, telecom, medical, automotive and aerospace equipment. Applicability depends on the product standard and the complete test configuration, rather than the generator name alone.
HAEFELY identifies its quality management system as ISO 9001:2015 certified. For procurement and quality reviews, request the current certificate, model-specific declaration of conformity, calibration documentation and applicable technical datasheets through Absolute EMC. Product-specific documentation should be used to confirm regulatory requirements and the supplied calibration scope.