Categories

EMSCOPE, 9kHz - 110MHz, 2 channel Receiver/LISN

EMSCOPE, 9kHz - 110MHz, 2 channel Receiver/LISN

NNBM 8124, 10 kHz - 150(400) MHz, High Voltage, 70A, single path, 5µH LISN

NNBM 8124, 10 kHz - 150(400) MHz, High Voltage, 70A, single path, 5µH LISN

NNBL 8226-2, 9 kHz - 100 MHz, 70A, 50µH, Two Path LISN

NNBL 8226-2, 9 kHz - 100 MHz, 70A, 50µH, Two Path LISN

NNBL 8226-HV, 9 kHz - 100 MHz, 70A, 50µH, Single Path LISN

NNBL 8226-HV, 9 kHz - 100 MHz, 70A, 50µH, Single Path LISN

NNBL 8226, 9 kHz - 100 MHz, 70A, 50µH, Single Path LISN

NNBL 8226, 9 kHz - 100 MHz, 70A, 50µH, Single Path LISN

NNBL 8225, 9 kHz - 100 MHz, 20A, 50µH, Single Path LISN

NNBL 8225, 9 kHz - 100 MHz, 20A, 50µH, Single Path LISN

NNBL 8229-HV, 9 kHz - 100 MHz, 200A, 50µH Single Path LISN

NNBL 8229-HV, 9 kHz - 100 MHz, 200A, 50µH Single Path LISN

CMDM 8700 B Common mode / Differential mode switch

CMDM 8700 B Common mode / Differential mode switch

NNBL 8230, 9 kHz - 100 MHz, 300A, 50µH Single Path LISN

NNBL 8230, 9 kHz - 100 MHz, 300A, 50µH Single Path LISN

CAP 10-8226-2, 10 µF Capacitor for MIL-STD-461 CS101, CS106

CAP 10-8226-2, 10 µF Capacitor for MIL-STD-461 CS101, CS106

VTSD 9561 F, 10dB, Diode Pulse Limiter

VTSD 9561 F, 10dB, Diode Pulse Limiter

VTSD 9561 D, 20dB, Diode Pulse Limiter

VTSD 9561 D, 20dB, Diode Pulse Limiter

Products

EMSCOPE, 9kHz - 110MHz, 2 channel Receiver/LISN

EMI Measurements:

  • FFT-based dual-channel receiver
  • According to CISPR16-1-1
  • Peak, Quasi-Peak, and Average Detectors
  • Resolution Bandwidth Filters of 200 Hz, 9 kHz, and 120 kHz (CISPR), and 1 kHz and 10 kHz (MIL)
  • The fastest receiver in the market: Line and Neutral measurements with the 3 detectors simultaneously (6 simultaneous measurements)

NNBM 8124, 10 kHz - 150(400) MHz, High Voltage, 70A, single path, 5µH LISN

  • Acc. to CISPR 25 Ed. 4, CISPR 16-1-2, DO 160, MIL-STD, or ISO 7637-2
  • impedance (5µH + 1 Ohm) || 50 Ohm
  • 70 A, 1000 V (DC)
  • Switchable 50Ohm Load on measurement port
  • 1 microfarad capacitor to ground on AE side
  • BNC-jack (Type N option)

NNBL 8226-2, 9 kHz - 100 MHz, 70A, 50µH, Two Path LISN

  • Measurement of interference for MIL-STD-461/462
  • 9 kHz - 100 MHz
  • 500VDC / 250VAC 50/60Hz / 140VAC 400Hz
  • Max current 70A (100A Short time)
  • Impedance of each path: 50 µH +5 Ω || 50 Ω ±20 %

NNBL 8226-HV, 9 kHz - 100 MHz, 70A, 50µH, Single Path LISN

  • Measurement of interference for MIL-STD-461/462
  • 9 kHz - 100 MHz
  • 800VDC / 800VAC 50/60Hz / 140VAC 400Hz
  • Max current 70A (100A Short time)
  • Impedance of each path: 50 µH +5 Ω || 50 Ω ±20 %

NNBL 8226, 9 kHz - 100 MHz, 70A, 50µH, Single Path LISN

  • Measurement of interference for MIL-STD-461/462
  • 9 kHz - 100 MHz
  • 250VDC / 250VAC 50/60Hz / 140VAC 400Hz
  • Max current 70A (100A Short time)
  • Impedance of each path: 50 µH +5 Ω || 50 Ω ±20 %

NNBL 8225, 9 kHz - 100 MHz, 20A, 50µH, Single Path LISN

  • Measurement of interference for MIL-STD-461/462
  • 9 kHz - 100 MHz
  • 250VDC / 250VAC 50/60Hz / 140VAC 400Hz
  • Max current 20A 
  • Impedance of each path: 50 µH +5 Ω || 50 Ω ±20 %

NNBL 8229-HV, 9 kHz - 100 MHz, 200A, 50µH Single Path LISN

  • Measurement of interference for MIL-STD-461/462
  • 9 kHz - 100 MHz
  • 1000VDC / 800VAC 50/60Hz 
  • Max current 200A
  • Impedance of each path: 50 µH +5 Ω || 50 Ω ±20 %

CMDM 8700 B Common mode / Differential mode switch

The measurement mode switch CMDM 8700 B expands the measurement possibilities of two V-LISN to T- and Delta-LISNs for the profound analysis of interference emissions.

NNBL 8230, 9 kHz - 100 MHz, 300A, 50µH Single Path LISN

  • Measurement of interference for MIL-STD-461/462
  • 9 kHz - 100 MHz
  • 250VDC / 250VAC 50/60Hz / 140VAC 400Hz
  • Max current 300A, (500A limited time)
  • Impedance of each path: 50 µH +5 Ω || 50 Ω ±20 %

CAP 10-8226-2, 10 µF Capacitor for MIL-STD-461 CS101, CS106

To be compliant to the standards DEF STAN 59 and DO 160 a 10 μF capacitor like the CAP 10 has to be connected to the mains connectors of the LISN.

VTSD 9561 F, 10dB, Diode Pulse Limiter

Diode Pulse Limiter with built-in 10 dB high power attenuator and fuse lamp to protect sensitive measuring equipment when measuring spectra with high energy. Thanks to the built-in fuse lamp, serious overload situations of sensitive equipment can be recognized fast and reliably. A replacement bulb is placed inside the unit. The pulse limiter prevents expensive equipment defects. The very flat frequency response allows high measurement accuracy, even if only a few sample values are used for correction.

VTSD 9561 D, 20dB, Diode Pulse Limiter

Diode Pulse Limiter with built-in 20 dB high power attenuator and fuse lamp to protect sensitive measuring equipment when measuring spectra with high energy. Thanks to the built-in fuse lamp, serious overload situations of sensitive equipment can be recognized fast and reliably. A replacement bulb is placed inside the unit. The pulse limiter prevents expensive equipment defects. The very flat frequency response allows high measurement accuracy, even if only a few sample values are used for correction.


Loading...