Categories

PSURGE 30.2 Modular 30 kV / 30 kA Surge Test System

PSURGE 30.2 Modular 30 kV / 30 kA Surge Test System

HTS 20-10, 20 kV, DC dielectric strength

HTS 20-10, 20 kV, DC dielectric strength

IPG 1218 / 1012 / 605, Insulation Test, 12kV, 10kV, 6.25kV

IPG 1218 / 1012 / 605, Insulation Test, 12kV, 10kV, 6.25kV

PG 12-400, 12kV, Impulse Wave Generator

PG 12-400, 12kV, Impulse Wave Generator

IPG 2025 / IPG 2436, Impulse Wave Generator 20kV or 24kV

IPG 2025 / IPG 2436, Impulse Wave Generator 20kV or 24kV

IPG 255, Insulation Tester, 8kV

IPG 255, Insulation Tester, 8kV

IPG 1201, Insulation Tester, 12kV

IPG 1201, Insulation Tester, 12kV

PG 6 250: VARISTOR TESTER

PG 6 250: VARISTOR TESTER

PG 6-364: HV Pulse Generator

PG 6-364: HV Pulse Generator

PG 10-504: 10kV Surge CWG

PG 10-504: 10kV Surge CWG

PG 12-804  12kV Surge CWG

PG 12-804 12kV Surge CWG

PG 24 - 2500 Surge Test Generator

PG 24 - 2500 Surge Test Generator

Products

PSURGE 30.2 Modular 30 kV / 30 kA Surge Test System

PSURGE 30.2 

  • Surge System
  • Up to 30 kV impulse voltage
  • Up to 30 kA impulse current

HTS 20-10, 20 kV, DC dielectric strength

High-Voltage DC Test Sets HTS 20-10 are designed for testing dc dielectric strength of components, insulations, air- and surface flash-over gaps. Also for testing SPDs according to IEC 61643-1. The test voltage can be adjusted from 0.2 kV up to 20 kV. The test voltage rises like a ramp from zero to the selected test voltage. The rate of rise can be adjusted from 100 V/sec up to 10000 V/sec. Then the test voltage remains at the selected value for the test time, which can be adjusted from 1 – 1000 sec. Figure: incl. option PA503

IPG 1218 / 1012 / 605, Insulation Test, 12kV, 10kV, 6.25kV

High-Voltage Pulse Generators IPG 1218 / 1012 / 605 generate standard impulse voltages with waveform 1.2 / 50 µs acc. to IEC 60060. They are designed for testing impulse dielectric strength of components, insulations, air- and surface flash-over gaps acc. to IEC. The peak value of the test voltage is continuously adjustable from 0.2 - 6.25 / 10 / 12 kV. Positive or negative polarity of the output voltage can be selected. A built-in voltage divider 1000:1 allows monitoring of the impulse output waveform during testing.

PG 12-400, 12kV, Impulse Wave Generator

High-Voltage Pulse Generator PG 12-400 generates standard impulse voltages with waveform 1.2 / 50 µs acc. to IEC 60060. It is designed for testing impulse dielectric strength of components, insulations, air- and surface flash-over gaps acc. to IEC.

IPG 2025 / IPG 2436, Impulse Wave Generator 20kV or 24kV

The HV - Impulse generators IPG 2025 and IPG 2436 create standard impulse voltages with waveform 1.2 / 50 µs acc. to IEC 60060. They are designed for testing impulse dielectric strength of components, insulations, air- and surface flash-over gaps according to the standards. The peak value of the test voltage is continuously adjustable from 2 - 20 kV or 2 - 24 kV. Positive or negative polarity of output voltage can be selected. A built-in voltage divider 1000:1 allows monitoring of the impulse output waveform during testing.

IPG 255, Insulation Tester, 8kV

The High-Voltage Pulse Generator IPG 255 is designed for testing of impulse dielectric strength of components, insulation, air-and surface flash-over gaps of watt-hour meters, static relays etc. according to IEC 60255, EN 61036, VDE 0435 part 303. Picture: incl. Option PA 503

IPG 1201, Insulation Tester, 12kV

The High-Voltage Pulse Generator IPG 1201 is designed for testing of impulse dielectric strength of components, insulation, air- and surface flashover gaps. It is specially used for testing surge withstand capability of insulation between accessible parts and hazardous live parts, e.g. terminals for connection of antenna and mains supply terminals, refer to EN 60065. Picture: incl. Option PA 503

PG 6 250: VARISTOR TESTER

The VARISTOR-TESTER PG 6-250 is a compact test generator for testing the surge current capability of varistors. The unit contains a combination wave generator and a surge voltage generator acc. to CCITT, ITU-T.

PG 6-364: HV Pulse Generator

The high-voltage impulse generator PG 6-364 generates standard impulse voltages with waveforms 1.2/50 µs and 10/700 µs. The Output voltage is adjustable between 0.2 kV and 6 kV. The polarity of the output voltage is selectable. Positive, negative or alternating polarity of the output voltage can be preselected. The generator is designed for dielectric testing of components and systems as well as testing of the electromagnetic compatibility of electronic systems and devices acc. to CCITT K17/K20/K22, ITU-T/K44, IEC 61000-4-5, VDE 0847.

PG 10-504: 10kV Surge CWG

The Combination Wave Generator PG 10-504 is a combined impulse-current-/impulse-voltage generator which, for high-impedance loads, RL > 100?, delivers a standard impulse voltage with waveform 1.2/50µs and, for short-circuited output, a standard impulse current with waveform 8/20µs. The generator allows surge testing of components and devices, the galvanic coupling of surges to cable shields, shielded enclosures and cabinets as well as testing electromagnetic compatibility, EMC, of electronic devices and systems against pulsed and conducted interference.

PG 12-804 12kV Surge CWG

The Combination Wave Generator PG 12-804 is a combined impulse-current-/impulse-voltage generator which, for high-impedance loads, RL > 100?, delivers a standard impulse voltage with waveform 1.2/50µs and, for short-circuited output, a standard impulse current with waveform 8/20µs. The generator allows surge testing of components and devices, galvanic coupling of surges to cable shields, shielded enclosures and cabinets as well as testing electromagnetic compatibility, EMC, of electronic devices and systems against pulsed and conducted interference.

PG 24 - 2500 Surge Test Generator

The Surge Test Generator PG 24-2500 is a combined impulse current-/impulse-voltage generator which, for high-impedance loads, RL > 100?, delivers a standard impulse voltage with waveform 1.2/50µs and, for short-circuited output, a standard impulse current with waveform 8/20µs, as defined by IEC 60. The peak value of the pulse output voltage can be adjusted from 0.5 kV to 24 kV. The peak short circuit current amplitude is 12 kA.

Loading...