CATAGORY

HTS 20-10, 20 kV, DC dielectric strength

HTS 20-10, 20 kV, DC dielectric strength

IPG 620/ IPG 1050/ IPG 1272 6kV, 10kV, 12kV

IPG 620/ IPG 1050/ IPG 1272 6kV, 10kV, 12kV

IPG 255, Insulation Tester, 8kV

IPG 255, Insulation Tester, 8kV

IPG 1218 / 1012 / 605, Insulation Test, 12kV, 10kV, 6.25kV

IPG 1218 / 1012 / 605, Insulation Test, 12kV, 10kV, 6.25kV

PG 12-400, 12kV, Impulse Wave Generator

PG 12-400, 12kV, Impulse Wave Generator

IPG 2025 / IPG 2436, Impulse Wave Generator 20kV or 24kV

IPG 2025 / IPG 2436, Impulse Wave Generator 20kV or 24kV

IPG 1201, Insulation Tester, 12kV

IPG 1201, Insulation Tester, 12kV

HCS 3-30 CAPACITOR DISCHARGE TEST SETUP 2 x 15kA

HCS 3-30 CAPACITOR DISCHARGE TEST SETUP 2 x 15kA

CCK20 Calibration kit for: PG 10-200, PG 12-360 and PG 20-100

CCK20 Calibration kit for: PG 10-200, PG 12-360 and PG 20-100

PG 5-200 / PG 10-1000, High Voltage Pulse Generator, 10/700µs, 5/350µs, 1.2/50µs

PG 5-200 / PG 10-1000, High Voltage Pulse Generator, 10/700µs, 5/350µs, 1.2/50µs

PG 12 - 1440, High Voltage Pulse Generator, 10/700µs, 1.2/50µs, 12kV

PG 12 - 1440, High Voltage Pulse Generator, 10/700µs, 1.2/50µs, 12kV

PG 14 - 1960, High Voltage Pulse Generator, 10/700µs, 0.5/700µs, 14kV

PG 14 - 1960, High Voltage Pulse Generator, 10/700µs, 0.5/700µs, 14kV

Products

HTS 20-10, 20 kV, DC dielectric strength

High-Voltage DC Test Sets HTS 20-10 are designed for testing dc dielectric strength of components, insulations, air- and surface flash-over gaps. Also for testing SPDs according to IEC 61643-1. The test voltage can be adjusted from 0.2 kV up to 20 kV. The test voltage rises like a ramp from zero to the selected test voltage. The rate of rise can be adjusted from 100 V/sec up to 10000 V/sec. Then the test voltage remains at the selected value for the test time, which can be adjusted from 1 – 1000 sec. Figure: incl. option PA503

IPG 620/ IPG 1050/ IPG 1272 6kV, 10kV, 12kV

HV - Impulse generators IPG 620, IPG 1050 and IPG 1272 create standard impulse voltages with waveform 1.2 / 50 µs acc. to IEC 60. The generators simulate surges caused by switching of inductive loads, power system switching, lightning strokes, etc. They are designed for testing of impulse dielectric strength of components, insulation, air-and surface flash-over gaps as well as for testing surge immunity of devices and systems acc. to CCITT - K22, ITU-T-K44. Picture: incl. option PA503

IPG 255, Insulation Tester, 8kV

The High-Voltage Pulse Generator IPG 255 is designed for testing of impulse dielectric strength of components, insulation, air-and surface flash-over gaps of watt-hour meters, static relays etc. according to IEC 60255, EN 61036, VDE 0435 part 303. Picture: incl. Option PA 503

IPG 1218 / 1012 / 605, Insulation Test, 12kV, 10kV, 6.25kV

High-Voltage Pulse Generators IPG 1218 / 1012 / 605 generate standard impulse voltages with waveform 1.2 / 50 µs acc. to IEC 60060. They are designed for testing impulse dielectric strength of components, insulations, air- and surface flash-over gaps acc. to IEC. The peak value of the test voltage is continuously adjustable from 0.2 - 6.25 / 10 / 12 kV. Positive or negative polarity of the output voltage can be selected. A built-in voltage divider 1000:1 allows monitoring of the impulse output waveform during testing.

PG 12-400, 12kV, Impulse Wave Generator

High-Voltage Pulse Generator PG 12-400 generates standard impulse voltages with waveform 1.2 / 50 µs acc. to IEC 60060. It is designed for testing impulse dielectric strength of components, insulations, air- and surface flash-over gaps acc. to IEC.

IPG 2025 / IPG 2436, Impulse Wave Generator 20kV or 24kV

The HV - Impulse generators IPG 2025 and IPG 2436 create standard impulse voltages with waveform 1.2 / 50 µs acc. to IEC 60060. They are designed for testing impulse dielectric strength of components, insulations, air- and surface flash-over gaps according to the standards. The peak value of the test voltage is continuously adjustable from 2 - 20 kV or 2 - 24 kV. Positive or negative polarity of output voltage can be selected. A built-in voltage divider 1000:1 allows monitoring of the impulse output waveform during testing.

IPG 1201, Insulation Tester, 12kV

The High-Voltage Pulse Generator IPG 1201 is designed for testing of impulse dielectric strength of components, insulation, air- and surface flashover gaps. It is specially used for testing surge withstand capability of insulation between accessible parts and hazardous live parts, e.g. terminals for connection of antenna and mains supply terminals, refer to EN 60065. Picture: incl. Option PA 503

HCS 3-30 CAPACITOR DISCHARGE TEST SETUP 2 x 15kA

The surge current testing device HCS 3-30 is used for surge current testing of capacitor windings. The capacitor to be tested is on an adjustable voltage, 0,005 - 3000 V, charged and then discharged via a triggerable switch.

CCK20 Calibration kit for: PG 10-200, PG 12-360 and PG 20-100

The Capacitor Calibration Kit CCK has been designed to measure the pulse output voltage of surge generators PG10-200, PG12-360 and PG20-100.

PG 5-200 / PG 10-1000, High Voltage Pulse Generator, 10/700µs, 5/350µs, 1.2/50µs

The high-voltage pulse generator PG 5-200/ 10-1000 creates standard impulse voltages with waveforms 1.2/50 µs and 10/700 µs. It is designed for dielectric testing of components and systems as well as testing of the electromagnetic compatibility of electronic systems and devices acc. to CCITT-K17/K20/K22, ITU-T/K44, IEC 61000-4-5 etc. They are designed for testing of impulse dielectric strength of components, insulation, air-and surface flash-over gaps as well as for testing surge immunity of devices and systems acc. to CCITT - K22, ITU-T-K44. Picture: incl. option PA503

PG 12 - 1440, High Voltage Pulse Generator, 10/700µs, 1.2/50µs, 12kV

The high-voltage impulse generator PG 12-1440 standard impulse voltages with waveforms 1.2/50 µs or 10/700 µs. The output voltage is adjustable between 0.5 kV and 12 kV. The polarity of the output voltage is selectable. Positive, negative or alternating polarity of the output voltage can be preselected.

PG 14 - 1960, High Voltage Pulse Generator, 10/700µs, 0.5/700µs, 14kV

The high-voltage impulse generator PG 14-1960 generates standard impulse voltages with waveforms 10/700 µs. The output waveform can be switched to 0.5/700µs wave. Output voltage is adjustable between 0.2 kV and 14 kV. The polarity of the output voltage is selectable. Positive, negative or alternating polarity of the output voltage can be preselected.

Loading...