Measure line and neutral conducted emissions with a two-channel FFT EMI receiver and built-in 16 A single-phase LISN. EMSCOPE supports common-mode and differential-mode analysis for filter development, with 30 MHz base coverage and an available 110 MHz upgrade. Add the optional CISPR 14-1 click meter license for discontinuous disturbance testing.
The Schwazbeck Biconical elements come in many sizes and offer different performances depending on what your needs are. For best low-frequency performance (good gain, low antenna factor), larger elements work better. The downfall of larger elements is handling or fitting in the test space. Many situations may not need outstanding performance with larger elements. The benefits of these elements and antenna baluns are that they all use the same connections (10mm), allowing for versatile sharing/switching of elements. No need to purchase a new antenna; get new elements.