The TBMDA5 modulated amplifier provides the necessary power, bandwidth and modulation for conducted immunity testing using CDNs in the frequency range from 150 kHz to 400 MHz. It is designed to be driven by the tracking generator output of spectrum analyzers.

The TBMDA-BCI25 modulated amplifier provides the necessary bandwidth and modulation for conducted immunity testing using BCI probes per ISO 11452-4 in the frequency range from 1 MHz to 400 MHz.

The TBMDA-CDN25 modulated amplifier provides the necessary power, bandwidth and modulation for conducted immunity testing using CDNs and BCI probes in the frequency range from 100 kHz to 250 MHz. 

The TBBT01 Bias-Tee is a device for measuring the saturation effects of power inductors and bias voltage effects on capacitors. The majority of available Bias-Tees for power inductor testing operate at low frequencies, rendering them unsuitable for evaluating decoupling/bias inductors of RF power amplifiers or EMC filters. 

The TBJT01 is a wideband injection transformer for control loop stability measurements. It provides galvanic isolation between the swept signal source and the control loop. The injection transformer is internally terminated with a 5 Ohm resistor and protected with a 100 mA fuse. The usable frequency range is 10 Hz to 45 MHz.

The TBJT02 is a wideband injection transformer for control loop stability measurements. It provides galvanic isolation between the swept signal source and the control loop. The injection transformer is internally terminated with a 5 Ohm resistor and protected with a 100 mA fuse. The usable frequency range is 1 Hz to 7 MHz.

Meets Section 15 DO160 Magnetic Effect

  • Magnetic Compass with better than 1deg Accuracy
  • Magnetometer HS 3D-SENS50T1  Hall-Sensor 
  • Zero-Gauss Chamber
  • Flexible Measuring tape, Non-Mitalic
  • EPS Foam Support for Compass
  • Transit Case for easy storage

The TBESDT1 ESD-Target is a current sensing transducer to verify ESD-Simulators. It is used to take measurements compliant with IEC 61000-4-2 up to 4 GHz.

  • DUT Current Ratings: 40A, 76A, 114A, 152A, 190A, 228A
  • Voltage Ripple: Up to 200 kHz (500 kHz)
  • Amplifier: BOLAB 100-TS Series 4-quadrant system
  • Load Dump Generator: BOLAB 10/63-210 1C
  • Switching: FIS 100-xx & FIS SM 96-2 (expandable)
  • Power Supply: BOLAB or third-party compatible
  • High-Voltage & Insulation Testing: G1-1G-T & 90-4K
  • Modular & Scalable: Full ISO 16750-2:2023 compliance

  • Full Compliance – Meets all ISO 7637-4 test requirements
  • Pulse A Testing – Simulates MOSFET/IGBT switching noise (100 kHz – 10 MHz)
  • Pulse B Testing – Low-frequency sinusoidal disturbances (3 kHz – 300 kHz)
  • High-Power RF Amplifier – 75W output (100 kHz – 400 MHz) for clean signal generation
  • Burst Generator – Supports configurable burst parameters (1–1000 cycles)
  • Power Meter & Directional Coupler – Accurate transient measurement (100 kHz – 10 MHz)
  • Integrated Transformer – Isolates high-voltage circuits & prevents transient damage
  • Scalable & Modular – Configurable for custom DUT testing needs
  • Turnkey Solution – Includes generator, amplifier, coupler, and switching solutions