Categories

CDG 7000 Conducted Immunity, 10 kHz - 400MHz

CDG 7000 Conducted Immunity, 10 kHz - 400MHz

CDG 7000-E Conducted Immunity Generator, (4)9 kHz - 1 GHz , No internal Amplifier

CDG 7000-E Conducted Immunity Generator, (4)9 kHz - 1 GHz , No internal Amplifier

FIS 100-200 Fast Interrupt Switch 100V/200Amps

FIS 100-200 Fast Interrupt Switch 100V/200Amps

CDG 7000-75-10 Magnetic & Conducted Immunity, 10 kHz - 250MHz

CDG 7000-75-10 Magnetic & Conducted Immunity, 10 kHz - 250MHz

400 - 6112, 2-Ch, 250kS/s, AnyWave Control Unit

400 - 6112, 2-Ch, 250kS/s, AnyWave Control Unit

400 - 6361, 2-Ch, 2.8MS/s, AnyWave Control Unit

400 - 6361, 2-Ch, 2.8MS/s, AnyWave Control Unit

100-TS, 4-Quadrant Voltage Amplifiers 400 W - 54,000 W

100-TS, 4-Quadrant Voltage Amplifiers 400 W - 54,000 W

100-TS, 4-Quadrant Current Amplifiers 400 W - 54,000 W

100-TS, 4-Quadrant Current Amplifiers 400 W - 54,000 W

AN-ABCD-300, 300 Amp Artificial Network, EV HV Testing

AN-ABCD-300, 300 Amp Artificial Network, EV HV Testing

AN-ABCD-60, 60 Amp Artificial Network, EV HV Testing

AN-ABCD-60, 60 Amp Artificial Network, EV HV Testing

100-TS, VW 80000 / LV 124 : Battery test systems Test systems for 12 V | 24 V | 48 V batteries

100-TS, VW 80000 / LV 124 : Battery test systems Test systems for 12 V | 24 V | 48 V batteries

100-TS, VW 80300 / LV 123 / LV 148 : HV Electric vehicle test systems

100-TS, VW 80300 / LV 123 / LV 148 : HV Electric vehicle test systems

Products

CDG 7000 Conducted Immunity, 10 kHz - 400MHz

The CDG 7000 is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields - including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, an RF power amplifier, a 3-channel RF voltmeter, and a directional coupler at a very affordable price.

CDG 7000-E Conducted Immunity Generator, (4)9 kHz - 1 GHz , No internal Amplifier

The CDG 7000-E is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields - including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, a 3-channel RF voltmeter, and a directional coupler at a very affordable price. Use an external Amplifier you already have or one that matches your application. 

  • The compact device comprises an RF signal generator, a 3-channel RF voltmeter, and a directional coupler.
  • Frequency range of the generator/power meter (4 kHz): 9 kHz – 1200 MHz
  • The frequency range of the directional coupler: 10 kHz – 1000 MHz, 200 W 
  • Depending on ext. amplifier:  IEC/EN 61000-4-6, IEC 60601-1-2 Ed. 4.1,  IEC 61000-4-39, MIL 461 CS 114, ISO 11452-4, ...

FIS 100-200 Fast Interrupt Switch 100V/200Amps

  • High current power stage (uni-directional)
  • Up to 32 channels for switching low-current signals (bi-directional)
  • Switching of resistive, inductive, capacitive passive, and active loads/devices
  • Input voltage up to 100V
  • Output current up to 200A DC

CDG 7000-75-10 Magnetic & Conducted Immunity, 10 kHz - 250MHz

The CDG 7000 is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields - including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, an RF power amplifier, a 3-channel RF voltmeter, and a directional coupler at a very affordable price. IEC 60601-1-2 calling out IEC 61000-4-39 magnetic immunity for close proximity testing requirements can also now be met with the 10 kHz unit. 

400 - 6112, 2-Ch, 250kS/s, AnyWave Control Unit

WaveMaster + AnyWave

BOLAB WaveMaster software and the BOLAB AnyWave control unit allow the control of power supplies as well as 4 quadrant amplifiers via the analog interfaces.

The powerful and easy-to-use BOLAB WaveMaster software is unique in the world. Without any knowledge in software development, designing ordinary and complex waveforms is very easy. A graphic waveform editor allows the generation

of individual curves in no time. Also, with tabular input, all types of waveforms can be produced instantly.

400 - 6361, 2-Ch, 2.8MS/s, AnyWave Control Unit

WaveMaster + AnyWave

BOLAB WaveMaster software and the BOLAB AnyWave control unit allow the control of power supplies as well as 4 quadrant amplifiers via the analog interfaces.

The powerful and easy-to-use BOLAB WaveMaster software is unique in the world. Without any knowledge in software development, designing ordinary and complex waveforms is very easy. A graphic waveform editor allows the generation

of individual curves in no time. Also, with tabular input, all types of waveforms can be produced instantly.

100-TS, 4-Quadrant Voltage Amplifiers 400 W - 54,000 W

  • DC - 200 kHz bandwidth DC 
  • MHz (small signal -3 dB)
  • Output voltage ±75 Vpk
  • Rise / fall time 100 V/µs
  • USB interface standard, LAN optional
  • Analog control input 0 ... ±10 V for control of voltage and current
  • Monitor outputs for measured voltage and current values (not all models)
  • Modularly extensible via master-slave mode
  • Parallel and Series Connections for two or more units

100-TS, 4-Quadrant Current Amplifiers 400 W - 54,000 W

  • DC - 200 kHz bandwidth DC 
  • MHz (small signal -3 dB)
  • Output voltage ±75 Vpk
  • Rise / fall time 100 V/µs
  • USB interface standard, LAN optional
  • Analog control input 0 ... ±10 V for control of voltage and current
  • Monitor outputs for measured voltage and current values (not all models)
  • Modularly extensible via master-slave mode
  • Parallel and Series Connections for two or more units

AN-ABCD-300, 300 Amp Artificial Network, EV HV Testing

AN-Series is an artificial Network that electrically recreates the vehicular power-net impedance for component tests of voltage class B (high voltage) components in laboratories and test benches. The AN-Series uses an analog system with a bandwidth covering up to 150 kHz. An artificial network like the AN-Series is crucial for the proper testing of all voltage class B components in both hybrid and electric vehicles.

In accordance with LV123, ISO 21498, MBN 11123, VW 80300, and IEC 61851-23.

AN-ABCD-60, 60 Amp Artificial Network, EV HV Testing

AN-Series is an artificial Network that electrically recreates the vehicular power-net impedance for component tests of voltage class B (high voltage) components in laboratories and test benches. The AN-Series uses an analog system with a bandwidth covering up to 150 kHz. An artificial network like the AN-Series is crucial for the proper testing of all voltage class B components in both hybrid and electric vehicles.

In accordance with LV123, ISO 21498, MBN 11123, VW 80300, and IEC 61851-23.

100-TS, VW 80000 / LV 124 : Battery test systems Test systems for 12 V | 24 V | 48 V batteries

  • Protocol reports
  • Generation of waveforms with synchronous data acquisition 
  • Modular Expandable
  • Individual Waveform Generation
  • Standard Libraries included
  • Unlimited Waveform size
  • 2 different Waveforms synchronously 
  • DLL's for LabView, Vector CANoe / CAPL, C#, C++, ANSI C, Python, etc.
  • Simulation of imported oscilloscope waveform

100-TS, VW 80300 / LV 123 / LV 148 : HV Electric vehicle test systems

BOLAB´s new and world´s unique solutions in testing High Voltage profiles for Electric Vehicles are very powerful, flexible, and modular.

Three different solutions for high-speed testing, a medium-range for covering most profiles, and a low budget. Powerful solutions for starting and gaining experience are available.

Modularity is one of the most important characteristics of BOLAB´s systems.

Start with a “small” system of 1 KW (1.000 V, 15 A) and expand module by module as applications require and budgets allow.

It was never this easy to get involved with high voltage tests for Electric Vehicles and to build up these tests to a most powerful solution.

Loading...