CS109 is a conducted susceptibility test under MIL-STD-461 that evaluates an equipment’s immunity to currents conducted through its chassis or enclosure. This test applies over a frequency range typically from 60 Hz up to 100 kHz. By injecting a controlled current onto the equipment structure, CS109 verifies the device’s ability to operate without performance degradation when exposed to potential structural currents in real-world environments.