Categories

DGA 9553 BNC, Attenuator, 1 watts, 2GHz, 3, 6, 10, 20, and 30 dB

DGA 9553 BNC, Attenuator, 1 watts, 2GHz, 3, 6, 10, 20, and 30 dB

DGA 9552 N, Attenuator, 5 watts, 18GHz, 3, 6, 10, 20, 30, & 40dB

DGA 9552 N, Attenuator, 5 watts, 18GHz, 3, 6, 10, 20, 30, & 40dB

NFCN 1356, 1356 kHz Compensation Network for HFRA 5164

NFCN 1356, 1356 kHz Compensation Network for HFRA 5164

NFCN 9734 - DC- 200 kHz Compensation Network

NFCN 9734 - DC- 200 kHz Compensation Network

NFCN 9731-100, DC- 180 Hz Compensation Network for HHS 5230-100

NFCN 9731-100, DC- 180 Hz Compensation Network for HHS 5230-100

NFCN 9732-85, 80 - 90 kHz Compensation Network for HHS 5206-8

NFCN 9732-85, 80 - 90 kHz Compensation Network for HHS 5206-8

NFCN 9732-120, 50-60 Hz, Compensation Network for HHS 5210-100

NFCN 9732-120, 50-60 Hz, Compensation Network for HHS 5210-100

EMCL- NW 10 / MN-1 EM Clamp Matching Network

EMCL- NW 10 / MN-1 EM Clamp Matching Network

VTSD 9561 D, 20dB, Diode Pulse Limiter

VTSD 9561 D, 20dB, Diode Pulse Limiter

SYMAT 40, Symmetrical Step Attenuator, 100 Ohms acc. EN 50561-1

SYMAT 40, Symmetrical Step Attenuator, 100 Ohms acc. EN 50561-1

VTSD 9561 F, 10dB, Diode Pulse Limiter

VTSD 9561 F, 10dB, Diode Pulse Limiter

TBAS3 10W Type N Attenuator Set

TBAS3 10W Type N Attenuator Set

Products

DGA 9553 BNC, Attenuator, 1 watts, 2GHz, 3, 6, 10, 20, and 30 dB

DGA 9553 BNC is a bidirectional attenuator, i.e. the attenuation and power capability specification is valid for both directions.

There is a large variety of applications for this attenuator: The measuring range of a spectrum analyzer can be increased. Any kind of meter can be protected against overload; it can be used to control the linearity of a meter reading. It can minimize measurement uncertainty caused by mismatched impedances. During an EMI receiver calibration, an attenuator directly at the pulse generator output is inevitable.

  • 3, 6, 10, 20, and 30 dB Values available
  • 50 Ohm, Low VSWR
  • 1 Watts

DGA 9552 N, Attenuator, 5 watts, 18GHz, 3, 6, 10, 20, 30, & 40dB

DGA 9552 N is a bidirectional attenuator, i.e. the attenuation and power capability specification is valid for both directions.

There is a large variety of applications for this attenuator: The measuring range of a spectrum analyzer can be increased. Any kind of meter can be protected against overload; it can be used to control the linearity of a meter reading. It can minimize measurement uncertainty caused by mismatched impedances. During an EMI receiver calibration, an attenuator directly at the pulse generator output is inevitable.

  • 3, 6, 10, 20, 30, and 40 dB Values available
  • 50 Ohm, Low VSWR
  • 5 Watts, 1 kW peak (5 μsec. pulse width, 0.25% duty cycle)
  • Optional storage case CCA

NFCN 1356, 1356 kHz Compensation Network for HFRA 5164

  • Compensation Network
  • For HFRA 5164
  • up to 26 A/m @ 50 Watts
  • 13.56 MHz

NFCN 9734 - DC- 200 kHz Compensation Network

  • Compensation Network
  • For: HHS 5206-16, HHS 5204-12, HHS 5202-9
  • up to 32 Arms
  • DC - 200 kHz

NFCN 9731-100, DC- 180 Hz Compensation Network for HHS 5230-100

  • Compensation Network
  • For HHS 5230-100
  • up to 8 Arms
  • DC - 180 kHz

NFCN 9732-85, 80 - 90 kHz Compensation Network for HHS 5206-8

  • Compensation Network
  • For HHS 5206-8
  • up to 11 Arms
  • 80 - 90 kHz (85 kHz)

NFCN 9732-120, 50-60 Hz, Compensation Network for HHS 5210-100

  • Compensation Network
  • For HHS 5210-100
  • up to 151 Arms
  • 50 - 60 Hz 

EMCL- NW 10 / MN-1 EM Clamp Matching Network

EMCL- NW 10 / MN-1 Matching Network • For use with the EMCL-20 in the frequency range 10 kHz – 150 kHz • For use with the CDN BCI-P1 in the frequency range 10 kHz – 150 kHz

VTSD 9561 D, 20dB, Diode Pulse Limiter

Diode Pulse Limiter with built-in 20 dB high power attenuator and fuse lamp to protect sensitive measuring equipment when measuring spectra with high energy. Thanks to the built-in fuse lamp, serious overload situations of sensitive equipment can be recognized fast and reliably. A replacement bulb is placed inside the unit. The pulse limiter prevents expensive equipment defects. The very flat frequency response allows high measurement accuracy, even if only a few sample values are used for correction.

SYMAT 40, Symmetrical Step Attenuator, 100 Ohms acc. EN 50561-1

  • Symmetrical 100 Ω step attenuator
  • Switchable between 0 dB, 10 dB, 20 dB, 30 dB, 40 dB and 50 dB
  • For measurement of PLC or PLT to discover dynamic performance
  • Acc. EN 50561-1:2012 chapter 9.2. Figure 4 shows the setup

VTSD 9561 F, 10dB, Diode Pulse Limiter

Diode Pulse Limiter with built-in 10 dB high power attenuator and fuse lamp to protect sensitive measuring equipment when measuring spectra with high energy. Thanks to the built-in fuse lamp, serious overload situations of sensitive equipment can be recognized fast and reliably. A replacement bulb is placed inside the unit. The pulse limiter prevents expensive equipment defects. The very flat frequency response allows high measurement accuracy, even if only a few sample values are used for correction.

TBAS3 10W Type N Attenuator Set

The TBAS3 RF 10W attenuator set consists of a 3dB, 6dB, 10dB and 20dB attenuator in a beech wood box.


Loading...