CATAGORY

EMSCOPE, 9kHz - 110MHz, 2 channel Receiver/LISN

EMSCOPE, 9kHz - 110MHz, 2 channel Receiver/LISN

EMSCOPE-RX2, 9kHz - 110MHz, 2 channel Receiver

EMSCOPE-RX2, 9kHz - 110MHz, 2 channel Receiver

EMSCOPE-RX4, 9kHz - 110MHz, 4 channel Receiver for 3 phase

EMSCOPE-RX4, 9kHz - 110MHz, 4 channel Receiver for 3 phase

AB-Precompliant Test Kits

AB-Precompliant Test Kits

MGA 1033; Magnetic Immunity DC-250 kHz, 800 Watts

MGA 1033; Magnetic Immunity DC-250 kHz, 800 Watts

HFa-1S, 16 Amp single phase Harmonics and Flicker

HFa-1S, 16 Amp single phase Harmonics and Flicker

HFa-1-16-Ref, 16 Amp single phase Harmonics and Flicker w/ Impedance Reference

HFa-1-16-Ref, 16 Amp single phase Harmonics and Flicker w/ Impedance Reference

CAR TE 21 Transient Emission Test  to ISO 7637-2

CAR TE 21 Transient Emission Test to ISO 7637-2

MF EASY, DC-400 kHz, MAGNETIC FIELD EXPOSURE ASSESSMENT SYSTEM

MF EASY, DC-400 kHz, MAGNETIC FIELD EXPOSURE ASSESSMENT SYSTEM

HFa-3-16, 16 Amp 3-phase Harmonics and Flicker

HFa-3-16, 16 Amp 3-phase Harmonics and Flicker

HFa-3-16-Ref, 16 Amp 3-phase Harmonics and Flicker w/Reference Impedance

HFa-3-16-Ref, 16 Amp 3-phase Harmonics and Flicker w/Reference Impedance

LSAOL 1.0, Laser Powered RF Link, 9kHz - 6GHz w/5-12VDC 2W power sourse

LSAOL 1.0, Laser Powered RF Link, 9kHz - 6GHz w/5-12VDC 2W power sourse

Products

EMSCOPE, 9kHz - 110MHz, 2 channel Receiver/LISN

EMI Measurements:

  • FFT-based dual-channel receiver
  • According to CISPR16-1-1
  • Peak, Quasi-Peak, and Average Detectors
  • Resolution Bandwidth Filters of 200 Hz, 9 kHz, and 120 kHz (CISPR), and 1 kHz and 10 kHz (MIL)
  • The fastest receiver in the market: Line and Neutral measurements with the 3 detectors simultaneously (6 simultaneous measurements)

EMSCOPE-RX2, 9kHz - 110MHz, 2 channel Receiver

EMI Measurements:

  • FFT-based dual-channel receiver
  • According to CISPR16-1-1
  • Peak, Quasi-Peak, and Average Detectors
  • Resolution Bandwidth Filters of 200 Hz, 9 kHz, and 120 kHz (CISPR), and 1 kHz and 10 kHz (MIL)
  • The fastest receiver in the market: Line and Neutral measurements with the 3 detectors simultaneously (6 simultaneous measurements)

EMSCOPE-RX4, 9kHz - 110MHz, 4 channel Receiver for 3 phase

EMI Measurements:

  • FFT-based dual-channel receiver
  • According to CISPR16-1-1
  • Peak, Quasi-Peak, and Average Detectors
  • Resolution Bandwidth Filters of 200 Hz, 9 kHz, and 120 kHz (CISPR), and 1 kHz and 10 kHz (MIL)
  • The fastest receiver in the market: Line and Neutral measurements with the 3 detectors simultaneously (6 simultaneous measurements)
  • Measure 4 lines of 3 phase LISN
  • The picture is shown with internal LISN [EMSCOPE RX4 LZ2]

AB-Precompliant Test Kits

Absolute EMC has designed low-cost pre-compliance systems to meet a wide range of RF emissions and immunity needs. Some form of pre-complaint testing is a must for any company that needs to demonstrate their product for EMC compliance.  This enables companies to be responsive when issues happen and to also be proactive before going to the lab to better your chances of passing the first time. 

MGA 1033; Magnetic Immunity DC-250 kHz, 800 Watts

The compact magnetic field generator and analyzer MGA 1030 allows susceptibility tests against magnetic fields from DC to 250 kHz according to the standard EN 55103-2 and their measurement according to EN 55103-1. In addition, EMC tests are possible according to various standards such as automotive, avionic and MIL-STD.; Generation of magnetic fields from DC to 250 kHz; Field strength up to 1000 A/m; EN 55103-1/2, MIL-STD 461, Automotive etc.; Accessories: Loop sensors, Helmholtz coils etc.;

HFa-1S, 16 Amp single phase Harmonics and Flicker

  • Full compliant system meeting the requirements 
  • IEC 61000-3-2 Harmoinc Emissions
  • IEC 61000-3-3 Flicker Emissons
  • USB controlled, Windows 10 compatible software included
  • 16 Amp, 120, and 230 Voltages, 50/60Hz

HFa-1-16-Ref, 16 Amp single phase Harmonics and Flicker w/ Impedance Reference

  • Full compliant system meeting the requirements 
  • IEC 61000-3-2 Harmoinc Emissions
  • IEC 61000-3-3 Flicker Emissons
  • USB controlled, Windows 10 compatible software included
  • 16 Amp, 120, and 230 Voltages, 50/60Hz

CAR TE 21 Transient Emission Test to ISO 7637-2

  • Modular construction
  • Electronically and mechanically (+ life time counter) triggerable load switches
  • Artificial Network with temperature control
  • Shunt resistors: 10 / 20 / 40 / 120Ω
  • Battery current: 50A / 100A

MF EASY, DC-400 kHz, MAGNETIC FIELD EXPOSURE ASSESSMENT SYSTEM

The MF EASY is a scalable and flexible multichannel measurement and assessment system for magnetic fields in the frequency range DC – 400 kHz. It is available with 5 or 10 (on request up to 15) fully isotropic measurement channels enabling simultaneous magnetic field measurements on 5 or 10 (15) measurement positions.

Different standard probe types (sizes and shapes) are available for the MF EASY. Customized probes are available on request. Iso-centrically arranged coil and Hall sensor enable a measurement frequency range from DC to 400 kHz and a measurement sensitivity suitable for assessing human exposure.

HFa-3-16, 16 Amp 3-phase Harmonics and Flicker

  • Full compliant system meeting the requirements 
  • IEC 61000-3-2 Harmoinc Emissions
  • IEC 61000-3-3 Flicker Emissions
  • USB controlled, Windows 10 compatible software included
  • Singel and 3 phase 16 Amp, 120 and 230 Voltages, 50/60Hz

HFa-3-16-Ref, 16 Amp 3-phase Harmonics and Flicker w/Reference Impedance

  • Full compliant system meeting the requirements 
  • IEC 61000-3-2 Harmoinc Emissions
  • IEC 61000-3-3 Flicker Emissions
  • USB controlled, Windows 10 compatible software included
  • Singel and 3 phase 16 Amp, 120 and 230 Voltages, 50/60Hz
  • Includes Refernec impedance

LSAOL 1.0, Laser Powered RF Link, 9kHz - 6GHz w/5-12VDC 2W power sourse

The LSAOL 1.0/1.1 Laser-Powered Analog Optical Links with integrated pre-amplifiers are low-noise RF signal transmission systems for 9 kHz to 6 GHz.

  • They are ideally suited for EMC emission testing.
  • The need for batteries is eliminated through laser-powered operation.
  • The LSAOL Front Unit is laser-powered and equipped with both low and high-band pre-amplifiers
  • LSAOL 1.0 provides an adjustable, 5 V to 12 V phantom power supply delivering up to 2W to external devices such as active antennas or pre-amplifiers.


Loading...