Standards

Products

The Coupling- / Decoupling Networks are used to inject common-mode disturbances to Equipment under Test (EuT). Further, the CDNs provide sufficient decoupling between Auxiliary Equipment (AE) and disturbance signal. The requirements for CDN and their application are described in the standard IEC 61000-4-6 (Immunity to conducted disturbances, induced by radio-frequency fields). CDNs have a common mode impedance of 150 Ohm and are available for a multitude of cable types and connectors.

The Coupling / Decoupling Networks are used to inject common-mode disturbances to Equipment under Test (EuT). Further, the CDNs provide sufficient decoupling between Auxiliary Equipment (AE) and disturbance signal. The requirements for CDN and their application are described in the standard IEC 61000-4-6 (Immunity to conducted disturbances, induced by radio-frequency fields). CDNs have a common mode impedance of 150 Ohm and are available for a multitude of cable types and connectors.

The CNA280 meets the specifications of the standard CISPR 16-1-2 A1, figure C1 (unit type A) and CISPR 16-1-3, app. B,Fig. 9. It is also required to calibrate EMI absorbing clamps like the MDS 21.

Linear polarized Logarithmic Periodic Broadband Antenna (Aluminium tubing) for Receive and Transmit Applications

Linear polarized Logarithmic Periodic Broadband Antenna combined with a 4:1 Broadband Dipole (Aluminium tubing) for Receive and Transmit Applications.

Linear polarized Logarithmic Periodic Broadband Antenna with Broadband Dipole (Aluminium tubing) for Receive and Transmit Applications.

Power frequency magnetic fields acc. to IEC 61000-4-8 Test levels continuous 3 / 10 / 30 / 100 / 300 A/m. Test level 1000 A/m short, with a special transformer. Pulsed magnetic fields acc. to IEC 61000-4-9 Test levels 100 / 300 / 1000 A/m

The High-Voltage Pulse Generator Type IPG 809 is designed for dielectric testing of X- and Y-capacitors with standard impulse voltages 1.7/46 µs –0/+50% up to 8 kV acc. to IEC 60384-14, EN 132400, VDE 0565 etc. Picture: incl. Option PA 503

The PG 10-150 consists essentially of a variable transformer with motor drive, isolating transformer, filter circuit, DUT with parallel capacitor and a high-voltage pulse generator. All settings in the power section are made on the control unit. The pulse-forming networks according to IEC 60384-14 are adjustable.

The HV-Pulse generator PG10-200 / PG12-360 is used for impulse voltage tests of solar modules (photovoltaic panels) with the standard surge voltage waveform 1.2/50 µs according to IEC 60060-1/2 up to 10 kV acc. to. IEC 61730-1/2 / EN 61730-1. For the surge voltage tests of solar modules, these are enveloped with a copper foil as described in the relative above standard. After that the connections of the solar modules are tested with surge voltage against the copper foils. The tight copper foil envelope required by the standard results in comparatively high capacitances of approx. 0 - 183 nF, which is switched in parallel to the output of the impulse generator.

Loading...