Standards

Products

The Conformity Assessment Business Model DCS06 Clamp is designed and tuned for optimal operation in the 100 kHz frequency range and provides efficient coupling of the Defence Standard 59-411 DCS06 pulse to the EUT at voltages up to 1 kV (single turn output) and 4 kV (4 turn output). A single turn monitor loop is provided for pulse amplitude measurement during the test.

In accordance with the pulse verification requirements given in Annex C of ISO 7637-2:2011 and Annex A of ISO 16750-2:2012, test pulses generated by automotive transient generators need to be verified both under no-load (open circuit verification) and loaded conditions with specified loads.

The High-Voltage Pulse Generator IPG 255 is designed for testing of impulse dielectric strength of components, insulation, air-and surface flash-over gaps of watt-hour meters, static relays etc. according to IEC 60255, EN 61036, VDE 0435 part 303. Picture: incl. Option PA 503

High-Voltage Pulse Generators IPG 1218 / 1012 / 605 generate standard impulse voltages with waveform 1.2 / 50 µs acc. to IEC 60060. They are designed for testing impulse dielectric strength of components, insulations, air- and surface flash-over gaps acc. to IEC. The peak value of the test voltage is continuously adjustable from 0.2 - 6.25 / 10 / 12 kV. Positive or negative polarity of the output voltage can be selected. A built-in voltage divider 1000:1 allows monitoring of the impulse output waveform during testing.

High-Voltage Pulse Generator PG 12-400 generates standard impulse voltages with waveform 1.2 / 50 µs acc. to IEC 60060. It is designed for testing impulse dielectric strength of components, insulations, air- and surface flash-over gaps acc. to IEC.

The broadband horn antenna BBHA 9120 B is a linear polarized double ridged horn antenna

  • 1 GHz to 10 (12) GHz
  • Type N (Female)

The broadband horn antenna BBHA 9120 A is a linear polarized double ridged horn antenna.

  • 800 MHz to 5 (10) GHz
  • Type N (Female)

The alternating voltage testing set ACT ESTER 6 is suitable for the execution of the high- voltage test from isolations to VDE 0113, VDE 0700 part of 500, VDE of 0551 etc. IEC 60335, IEC 60204, IEC 60598, IEC 60745 The device essentially consists of a regulating transformer with a motor drive, a high voltage transformer, and a control unit. The output voltage can be adjusted by 0 - 10 kV.

  • 30 MHz - 6 GHz, 40dB Gain, 2.5dB N.F.
  • Compensation long cable loss for EMI Measurement
  • Improve system noise floor flatness
  • High EMI performance
  • High linearity LNA for EMI measurement
  • High dynamic range
  • Unconditionally Stable
  • State-of-the-Art Technology

The front-chopped-wave generator IPG 506 is used for measuring dc spark-over voltage and impulse spark-over voltage of over-voltage protectors according to CCITT / ITU-T, K12. Dc spark-over voltage: A linearly rising voltage, rate of rise 100 V/s up to 640 V, is connected to the device under test. The spark-over voltage measured is shown in the display. Impulse spark-over voltage: A linearly rising impulse voltage, rate of rise 100 V/µs up to 5000 V/µs, open loop amplitude 5000 V, is connected to the device under test. The spark-over voltage is measured by use of a peak detector. The result is shown in the display. A built-in impulse voltage divider allows measurement of the spark-over voltage by use of an externally connected scope. Picture: incl. Option PA 503

Loading...