The surge current testing device HCS 3-30 is used for surge current testing of capacitor windings. The capacitor to be tested is on an adjustable voltage, 0,005 - 3000 V, charged and then discharged via a triggerable switch.
The Capacitor Calibration Kit CCK has been designed to measure the pulse output voltage of surge generators PG10-200, PG12-360 and PG20-100.
The capacitive Coupling-/Decoupling Networks CDN 5416/7416/10416/12416 are used in combination with the Multi-CE5 or the Surge generators PG 7-250, PG 10-504, PG 12-804 and allow superimposition of surge and burst test pulses to the 3-phase mains voltage of the device under test.
The capacitive Coupling-/Decoupling Networks CDN 5432/7432/10432/12432 are used in combination with the Multi-CE5 / Multi-CE7 or the Surge generators PG 7-250, PG 10-504, PG 12-804 and allow superimposition of surge and burst test pulses to the 3-phase mains voltage of the device under test.
The capacitive Coupling-/Decoupling Networks CDN 5463/7463/10463/12463 are used in combination with the Multi-CE5 / Multi-CE7 or the Surge generators PG 7-250, PG 10-504, PG 12-804 and allow superimposition of surge and burst test pulses to the 3-phase mains voltage of the device under test.
The capacitive Coupling-/Decoupling Networks CDN 54125 / 74125 / 104125 / 124125 are used in combination with the Multi-CE5 / Multi-CE7 or the Surge generators PG 7-250, PG 10-504, PG 12-804 and allow superimposition of surge and burst test pulses to the 3-phase mains voltage of the device under test.
The high-voltage pulse generator PG 5-200/ 10-1000 creates standard impulse voltages with waveforms 1.2/50 µs and 10/700 µs. It is designed for dielectric testing of components and systems as well as testing of the electromagnetic compatibility of electronic systems and devices acc. to CCITT-K17/K20/K22, ITU-T/K44, IEC 61000-4-5 etc. They are designed for testing of impulse dielectric strength of components, insulation, air-and surface flash-over gaps as well as for testing surge immunity of devices and systems acc. to CCITT - K22, ITU-T-K44. Picture: incl. option PA503
The high-voltage impulse generator PG 12-1440 standard impulse voltages with waveforms 1.2/50 µs or 10/700 µs. The output voltage is adjustable between 0.5 kV and 12 kV. The polarity of the output voltage is selectable. Positive, negative or alternating polarity of the output voltage can be preselected.
The high-voltage impulse generator PG 14-1960 generates standard impulse voltages with waveforms 10/700 µs. The output waveform can be switched to 0.5/700µs wave. Output voltage is adjustable between 0.2 kV and 14 kV. The polarity of the output voltage is selectable. Positive, negative or alternating polarity of the output voltage can be preselected.
The high-voltage impulse generator PG 20-4000 generates standard impulse voltages with waveform 10/700 µs. The output voltage is adjustable between 1 kV and 20 kV. The polarity of the output voltage is selectable, positive or negative.