Standards

Products

  • Measurement of interference for MIL-STD-461/462
  • 9 kHz - 100 MHz
  • 250VDC / 250VAC 50/60Hz / 140VAC 400Hz
  • Max current 70A (100A Short time)
  • Impedance of each path: 50 µH +5 Ω || 50 Ω ±20 %

  • Measurement of interference for MIL-STD-461/462
  • 9 kHz - 100 MHz
  • 250VDC / 250VAC 50/60Hz / 140VAC 400Hz
  • Max current 20A 
  • Impedance of each path: 50 µH +5 Ω || 50 Ω ±20 %

  • High Current 4 path LISN (3-Phase & Single-Phase)
  • Line Impedance Stabilisation Network
  • Connector: CEE plug (IEC 60309) & CEE 7/4 
  • 9 kHz to 30 MHz
  • 250/400 VAC, 400 VDC, 16 A (16A for CEE 7/4)
  • (50 µH+5 Ω) || 50 Ω   
  • CISPR 16-1-2

  • 2 path LISN (Single-Phase)
  • Line Impedance Stabilisation Network
  • Connector: CEE 7/4 
  • 9 kHz to 30 MHz
  • 250 VAC, 400 VDC, 16 A 
  • (50 µH+5 Ω) || 50 Ω   
  • CISPR 16-1-2

  • Acc. to CISPR 25 Ed. 4, CISPR 16-1-2, or ISO 7637-2
  • impedance (5µH + 1 Ohm) || 50 Ohm
  • 800 A, 1000 V (DC)
  • Switchable 50Ohm Load on measurement port
  • 1 microfarad capacitor to ground on AE side
  • BNC-jack (Type N option)

  • Acc. to CISPR 25 Ed. 4, CISPR 16-1-2, or ISO 7637-2
  • impedance (5µH + 1 Ohm) || 50 Ohm
  • 250 A, 1000 V (DC)
  • Switchable 50Ohm Load on measurement port
  • 1 microfarad capacitor to ground on AE side
  • BNC-jack (Type N option)

  • Acc. to CISPR 25 Ed. 4, CISPR 16-1-2, or ISO 7637-2
  • impedance (5µH + 1 Ohm) || 50 Ohm
  • 200 A, 1000 V (DC)
  • Switchable 50Ohm Load on measurement port
  • 1 microfarad capacitor to ground on AE side
  • BNC-jack (Type N option)

  • Impedance Stabilisation Network (ISN)
  • acc. CISPR 22 Ed.5.5:2006, (CISPR 32)
  • Unshielded twisted pairs (UTP) or communication ports 
  • With 2, 4, 6, or 8 wires

  • for testing 3 line mains (with PE)
  • CISPR 15, EN 55015
  • 30 MHz - 300 MHz

The magnetic fixture „8158 Magbase“ can be used to fix a NTFM 8158, a CAT5 8158, or a CAT3 8158 to a steel wall vertically.