Standards

Products

  • for testing 2 line mains (without PE)
  • Also works as CDNE AF2
  • CISPR 15, EN 55015
  • 30 MHz - 300 MHz

  • Adapter for the calibration of a CDN
  • For ISN S1, ISN S8, CDN, or a CDNE
  • EN 61000-4-6, EN 55015,  CISPR 15,  CISPR 16-1-x,  CISPR 16-2-x
  • DC - 500 MHz
  • 6 W

The original ABSOLUTE EMC Tripod is explicitly designed for the EMC market. A low-cost and easy-to-use tripod with no metallic parts with the exception of the antenna connection screw. The EMC Tripod is easy to assemble, take apart, and store. It is fully adjustable in height with the center mast section. Materials used are low permittivity allowing for use in most EMC applications to hold antennas, cameras, RF field probes, cables off the floor, and other support possibilities. If any plastic pieces break, they will be replaced free of charge for the product's life.

  • Common-Mode Absorbing Clamp
  • (10) 30 - 200 (1000)MHz
  • Suppress unwanted common mode currents
  • Cable bundles maximum diameter of 26 mm
  • acc. CISPR 16-1-4

  • Full compliant system meeting the requirements 
  • IEC 61000-3-2 &  IEC 61000-3-12 Harmoinc Emissions
  • IEC 61000-3-3 &  IEC 61000-3-11 Flicker Emissions
  • USB controlled, Windows 10 compatible software included
  • Singel and 3 phase 35 Amp, 120 and 230 Voltages, 50/60Hz
  • Includes Reference Impedance

The SteppIR SY3-EMC Auto-tuned Yagi system is the solution to MIL-STD-461G and RS-103 for radiated susceptibility testing over the 30-200 MHz frequency range – making it the only system in the world that can legitimately claim to reach or exceed the required 200 V/m @1 Meter, at the fundamental frequency.

The original ABSOLUTE EMC Monopole is explicitly designed for the EMC market. A low-cost and easy-to-use monopole with no metallic parts, with the exception of the antenna connection screw. The EMC Monopole is easy to assemble. It is fully adjustable in height with the center mast section. Materials used are low permittivity allowing for use in most EMC applications to hold antennas, cameras, RF field probes, cables off the floor, and other support possibilities. The monopole design allows for a small footprint for easy maneuvering around and reduces tripping caused by tripods. If any plastic pieces break, they will be replaced free of charge for the product's life.

The CAR coupling network 50-1 is used to couple, according to ISO 7637-4:2020, the required sinusoidal disturbances into the DUT. This transformer also facilitates d.c. isolation of the LF generator from the DUT. The transformer has a current rating of 50A (rms) for the DUT.

  • Simulator for sinusoidal disturbance
  • 75 Watts
  • Frequency range 100kHz – 250MHz
  • Overvoltage protection

  • Coupling balun transformer
  • 7637-4 pulse A line-to-line-coupling
  • sheath current filter
  • 50Ω terminated

Loading...