  • DC - 200 kHz bandwidth DC 
  • MHz (small signal -3 dB)
  • Output voltage ±75 Vpk
  • Rise / fall time 100 V/µs
  • USB interface standard, LAN optional
  • Analog control input 0 ... ±10 V for control of voltage and current
  • Monitor outputs for measured voltage and current values (not all models)
  • Modularly extensible via master-slave mode
  • Parallel and Series Connections for two or more units

  • DC - 200 kHz bandwidth DC 
  • MHz (small signal -3 dB)
  • Output voltage ±75 Vpk
  • Rise / fall time 100 V/µs
  • USB interface standard, LAN optional
  • Analog control input 0 ... ±10 V for control of voltage and current
  • Monitor outputs for measured voltage and current values (not all models)
  • Modularly extensible via master-slave mode
  • Parallel and Series Connections for two or more units

AN-Series is an artificial Network that electrically recreates the vehicular power-net impedance for component tests of voltage class B (high voltage) components in laboratories and test benches. The AN-Series uses an analog system with a bandwidth covering up to 150 kHz. An artificial network like the AN-Series is crucial for the proper testing of all voltage class B components in both hybrid and electric vehicles.

In accordance with LV123, ISO 21498, MBN 11123, VW 80300, and IEC 61851-23.

AN-Series is an artificial Network that electrically recreates the vehicular power-net impedance for component tests of voltage class B (high voltage) components in laboratories and test benches. The AN-Series uses an analog system with a bandwidth covering up to 150 kHz. An artificial network like the AN-Series is crucial for the proper testing of all voltage class B components in both hybrid and electric vehicles.

In accordance with LV123, ISO 21498, MBN 11123, VW 80300, and IEC 61851-23.

Highlights of the CS116 Damped Sinusoid Generator

  • MIL-STD 461 CS115+CS116 Compliant: Meets stringent military testing standards.
  • Flexible Frequency Options: Choose from 6, 9, or 17 test frequencies.
  • Comprehensive Accessories: Includes injection probe, attenuator, oscilloscope, and control software.
  • Efficient Operation: Single signal output reduces test time and supports automation.
  • User-Friendly Control: Easily controlled via RS232 and USB interfaces.
  • Robust Design: Durable construction with wide power compatibility (90–264 Vac).

Optimize your naval and industrial testing with the CS116 & CS115 Damped Sinusoid & Switch Transient Generator—precision and efficiency combined.

  • Capability:
    • Spectral scan, spatial scan, peak-hold, continuous scanning, spectral and spatial comparison, scripting, limit lines, and report generation.
  • Spatial scan time:
    • Continuous real-time or sub-second single scan for the entire scan area is dependent on spectrum analyzer performance.
  • Spectral scan time:
    • 45 seconds for L 10 cm x W 10 cm (L 4” x W 4”) PCB with a 100 MHz span and 100 kHz RBW. Scanning area, span, and RBW are user-selectable within spectrum analyzer specifications
  • EMViewer Software
    • We recommend you use the EMViewer software for best results.  A Yearly subscription or a once-off purchase is available. 
  • Supported operating systems: Windows 10®
  • Supported CAD overlays: Standard Gerber© RS274x format and HPGL format

Audio Transformer 200W, 50A

  • 160x155x200mm
  • 2:1 ratio 
  • 200 W Maximum30Hz - 250 kHz
  • 100 W Maximum at15 Hz - 30 Hz
  • Insulation Resistance Test - 2kV

  • Capability:
    • Spectral scan, spatial scan, peak-hold, continuous scanning, spectral and spatial comparison, scripting, limit lines, report generation, and notes.
  • Spatial scan time:
    • Continuous real-time for the entire scan area (1,218 probes activated) when Level 1 is selected:  5 sec.
    • Selected area 2.25 cm x 2.25 cm, 9 probes activated.
    • Level 1: 
  • Spectral scan time:
    • 11 seconds for L 10 cm x W 10 cm (L 4” x W 4”, 178 probes activated) from 10 MHz span to 110 MHz and 122 kHz RBW. Scanning area, span, and RBW are user-selectable within spectrum analyzer specifications
  • Supported operating systems: Windows 10®
  • Supported overlays: Picture in JPEG format 
  • Standard Gerber© RS274x format and HPGL form

  • Capability:
    • Spectral scan, spatial scan, peak-hold, continuous scanning, spectral and spatial comparison, scripting, limit lines, report generation, and notes.
    • Customization of the robot arm size, any size, is possible. 
  • Spatial scan time:
    • The scan time depends on size and area
  • Ideal for large component boards
    • The robotic arm allows for advanced scans on complex items
  • Supported operating systems: Windows 10®
  • Supported overlays: Picture in JPEG format 
  • Standard Gerber© RS274x format and HPGL form

" A Probe Kit on Steroids"

  • Fully integrated with Y.I.C. Technologies EMViewer software and EMProbe
  • Normalization and correction when using the EMViewer software
  • Flat response within the range of operation
  • Slim Design and Protective Coating
  • 18GHz Measured Cable included

Loading...