Standards

Products

2uH Line Impedance Stabilisation Network LISN – ECSS-E-ST-20-07C

B-version two-path 2 µH LISN for spacecraft-related conducted measurements based on ECSS-E-ST-20-07C.

  • LISN type: V-AMN, 50 OHM // 2 µH
  • Characterized frequency range: 10 Hz – 200 MHz
  • DC Resistance: 100 mOHM per path
  • Internal capacitor: 10000 µF between “+” path and “-“ path; polarized
  • Maximum current: 25 A continuous

50uH Line Impedance Stabilisation Network LISN – CISPR 16

Single-path 50 µH LISN for conducted-emissions measurements on AC- or DC-powered equipment.

  • ISN type: single path V-AMN, configurable (jumper) as 50OHM/50µH+5 OHM or 50OHM/50µH; no 250µH pre-filter
  • Characterized Frequency range: 10 kHz – 100 MHz
  • DC Resistance: 25 mOHM
  • Maximum current: 32A continuous
  • Operating voltage range: 0 – 500V DC; 0 – 270V AC (50/60 Hz), 0 – 120V AC (400 Hz)

DC coupled power amplifier

Low-impedance, DC-coupled power amplifier for immunity injection and other demanding low-frequency drive applications.

  • 3 dB bandwidth: DC – 3 MHz, useable up to 10 MHz
  • Output power: 150 W, depending on load impedance
  • Voltage gain: switchable; 0 dB, 10 dB, 20 dB, 30 dB, 40 dB
  • Operating temperature range: -20°C to +40°C
  • Dimensions: W 300 mm x H 150 mm x L 420 mm

injection transformer

Injection transformer for low-frequency conducted-immunity applications across military, aviation and automotive test methods.

  • Compliance: RoHS
  • Turns ratio, primary to secondary: 2:1
  • Impedance ratio, primary to secondary: 4:1
  • Typical secondary (load) impedance: ≥ 0.5 ohm
  • Characterized freq. range: 10 Hz to 250 kHz

injection transformer

Injection transformer providing isolation and high-pass coupling for CS101-related immunity measurements.

  • Compliance: RoHS
  • Impedance: 50 OHM
  • Turns ratio: 1:1; 56nF Y2 coupling capacitor on the EUT side
  • Characterized freq. range: 10 Hz to 100 MHz
  • 3 dB frequency range: 50 kHz – 50 MHz typ.

Loop Antenna Pre-Amplifier

Low-frequency loop-antenna preamplifier intended to improve the usable sensitivity of the TBMA6-P.

  • Frequency range: 9 kHz to 30 MHz
  • Gain: 43 dB, typ.
  • Input return loss: < -15 dB @ 9 kHz to 30 MHz, typ.
  • Output return loss: < -20 dB @ 9 kHz to 30 MHz, typ.
  • Noise voltage: 1nV / √Hz, typ.

50 µH 16 A LISN with Switchable RF Protection

  • Type — Single-phase 50 µH LISN for CISPR 16-1-2
  • Current — Up to 16 A at 23 °C, depending on socket. US NEMA 5-15: 15 A.
  • Operating voltage — Up to 250 V AC at 50/60 Hz or 250 V DC
  • Frequency — 9 kHz–30 MHz
  • Key feature — Line/neutral selector with switchable +6 dBm limiter, 10 dB attenuation, and 150 kHz–30 MHz high-pass filtering

5uH Line Impedance Stabilisation Network LISN

Compact 5 µH, 10 A LISN for conducted-emissions measurements on DC-powered equipment.

  • Frequency range: 10 kHz – 400 MHz; depending on standard and external capacitor
  • DC Resistance: 40 m?
  • Continuous current: 10A
  • Nominal operating voltage range: 0 – 60V DC
  • Absolute maximum rating of internal components: 200V DC; external 1µF capacitor: 100V

5uH Line Impedance Stabilization Network

Configurable, high-current 5 µH LISN for automotive, military and aviation conducted measurements.

  • Supported standards: CISPR 16-1-2, CISPR 25, MIL-STD-461G, DO-160, ISO11452-4 and ISO 7637-2
  • Characterized frequency range: 10 kHz – 400 MHz
  • DC Resistance: < 5 mOHM Source+ to EUT+; < 5 m? Source- to EUT
  • Maximum current: 100A; see plot with heat up characteristics, chapter 8
  • Maximum operating voltage range: 0 – 500V AC @50/60 Hz, 250V AC @ 400Hz, 1000V DC

V-Y-Δ DC-Line Impedance Stabilization Network

DC-line LISN providing V, Y and delta measurement arrangements for conducted-emissions work.

  • Frequency range: 9 kHz to 30 MHz
  • Max. continuous current: 25A
  • Max. current for 15 minutes: 32A Max.
  • DC – voltage: 1000 V
  • Mode A, mode B impedance: 150 ± 30 OHM

Loading...