Standards

Products

RF Power Splitters, Combiners and VSWR Bridges

Compare two-way RF splitters and combiners with VSWR bridges for forward and reverse power measurements.

  • TBRFPSX — Family of two-way RF power splitters/combiners for distributing and combining signals.
  • TBSWR-200K500 — High-power VSWR bridge for forward/reverse power measurements from 200 kHz to 500 MHz.
  • TBSWR-300K6000 — General-purpose VSWR bridge for forward/reverse power measurements from 300 kHz to 6 GHz.
  • TBSWR-600K700 — High-power VSWR bridge for forward/reverse power measurements from 600 kHz to 700 MHz.
  • TBSWR-60K500 — High-power VSWR bridge for forward/reverse power measurements from 60 kHz to 500 MHz.

Coupling Decoupling Networks Emission

Two-line emission coupling/decoupling network for the CISPR 15 alternative lighting-equipment measurement method.

  • Compliance: CISPR 15 (IEC / EN 55015) Edition 9, CISPR 16-1-2, CISPR 16-2-1
  • Maximum supply voltage: 300V AC, 600V DC
  • Maximum current: 16A
  • Frequency range: 30 MHz – 300 MHz
  • Common mode impedance: 150 ? +10 / – 20 ? (EUT port)

Coupling Decoupling Networks Emission

Three-line emission coupling/decoupling network for the CISPR 15 alternative lighting-equipment measurement method.

  • Compliance: CISPR 15 (IEC / EN 55015) Edition 9, CISPR 16-1-2, CISPR 16-2-1
  • Maximum supply voltage: 300V AC, 600V DC
  • Maximum current: 16A
  • Frequency range: 30 MHz – 300 MHz
  • Common mode impedance: 150 ? +10 / – 20 ? (EUT port)

TBCMC-1 RF Common Mode Choke

RF common-mode choke for reducing ground-loop currents in shunt-method impedance measurements.

  • Compliance: RoHS
  • Differential mode impedance: 50 Ohm, typ.
  • Characterized frequency range: 1 Hz – 1 GHz
  • Recommended frequency range: 10 Hz – 500 MHz
  • Differential mode power rating: max. 130 W up to 1 GHz

Differential Amplifier

Differential measurement amplifier with 1:50 attenuation and a flat response from DC to 250 MHz.

  • Differential amplifier for CS101 test setups.
  • General-purpose differential amplifier
  • Frequency range: DC – 310 MHz, 3 dB bandwidth, typical
  • Gain: 1:50
  • Rise time: ≤ 2.3 ns ( 200mV step)

DC-coupled Low Noise Amplifier

DC-coupled low-noise amplifier providing 20 dB gain for measurement and signal-driving applications.

  • Frequency range: DC – 40 MHz, 3 dB band width, typical
  • Gain: 20 dB, typ. ( ? linear voltage gain 10) with 50 Ohm load impedance
  • RF-connectors: BNC-female
  • Input impedance: 50 ?
  • Input return loss: > 30 dB, typ.

EM-Clamp Calibration Fixture

Calibration fixture for EM-clamp common-mode impedance verification using the IEC/EN 61000-4-6 procedure.

  • Compliance: IEC/EN 61000-4-6, Annex A
  • Nominal frequency range: 150 kHz – 80 MHz
  • Usable frequency range: 10 kHz – 1 GHz
  • Nominal impedance: 248 ?
  • Impedance range: ~ 230? – 260 ?

Two balanced pairs ISN

Impedance stabilization network for measuring common-mode conducted emissions on two balanced signal pairs.

  • Frequency Range: 150 kHz – 30 MHz
  • Impedance (asymmetric): 150 ?± 20 ?
  • Phase (asymmetric): 0° ± 20°
  • Longitudinal Conversion Loss (LCL): CISPR 22 item 9.6.2.c)1) page 24
  • Voltage Division Ratio (VDF) for asymmetrical voltage: 10 dB +/- 1 dB

ESD-Target mounting panel

ESD-target mounting panel sized for the 2025 Edition 3 requirements of IEC 61000-4-2.

  • Compliance: IEC 61000-4-2 Edition 3
  • Dimensions: 120 cm x 160 cm
  • ESD Target Position: 100 cm above ground
  • Panel Material: Aluminium A5052, 2mm thickness
  • Support Frame: 2020 extruded aluminium profiles; 120cm x 160 cm x 50 cm

Pre-Compliance Load Dump Simulator

Bench load-dump simulator for checking automotive power-input protection during product development.

  • Rise time: adjustable; typ. 100 µs – 10 ms
  • Fall time: adjustable; typ. 700 ms – 1s
  • Pulse: single pulse or five pulses at 10-second intervals
  • Ri: 2 Ohm
  • EUT current: 3 A max. in a 12 V system; 1.5 A max. in a 24 V system

Loading...