TekBox TBL5063-3 50uH Line Impedance Stabilisation Network LISN

50 µH 16 A LISN with Switchable RF Protection

  • Type — Single-phase 50 µH LISN for CISPR 16-1-2
  • Current — Up to 16 A at 23 °C, depending on socket. US NEMA 5-15: 15 A.
  • Operating voltage — Up to 250 V AC at 50/60 Hz or 250 V DC
  • Frequency — 9 kHz–30 MHz
  • Key feature — Line/neutral selector with switchable +6 dBm limiter, 10 dB attenuation, and 150 kHz–30 MHz high-pass filtering

TBL5016-2C Manual

TBL5063-3 Technical Document

SPECIFICATIONS

TBL5016-2B 50 µH 16 A LISN with Dual RF Outputs

TBL5016-2B Single-phase LISN with independent line and neutral BNC outputs for conducted-emissions work and simultaneous connection to a LISN Mate.

Technical specifications

Measurement range 9 kHz–30 MHz
Network impedance 50 Ω ? (50 µH + 5 Ω)
Maximum line voltage up to 250 V AC at 50/60 Hz or DC
Current rating 16 A at 23 °C subject to socket rating
RF outputs two 50 Ω BNC outputs
Power inlet IEC 60320 C19 power inlet
Artificial hand 220 pF + 511 Ω artificial hand
Protective earth switchable PE
Operating environment +5 to +40 °C, 5–80% RH

Applications

CISPR 16-1-2 conducted-emissions measurements.

Ordering and setup

Specify EU, US, AU or UK EUT socket. US NEMA 5-15 and AU options are rated 15 A; UK is rated 13 A. The manual lists a mains cord, coaxial measurement cable and BNC termination with the unit. Select external RF input protection for the receiver as needed.

Compare the related model

TBL5016-2C Single-phase LISN with a line/neutral selector and switchable limiter, attenuator and high-pass filter in the measurement path.

 
OTHER PRODUCTS IN THE SAME CATEGORY:
Loading...