Standards

Products

Modulated Wideband Power Amplifier

100 W modulated amplifier for conducted-immunity testing with bulk-current injection probes.

  • CW amplifier (modulation off)
  • 1 kHz, 80% AM modulation
  • 1 kHz, 50% duty cycle pulse modulation
  • 217 Hz, 12.5% duty cycle pulse modulation
  • VSWR monitoring

Balanced VHF Line Impedance Stabilization Network

Balanced VHF artificial-mains network providing defined RF termination for conducted-interference measurements.

  • Designed for mains supplied EUTs with or without protective Earth
  • Frequency range: 30-300 MHz
  • Maximum supply voltage: 250V AC
  • Maximum supply current: 16 A rms
  • Defined termination impedance

Modulated Wideband Driver Amplifier

Modulated wideband driver amplifier for immunity test signal generation in the 1–3 GHz range.

  • Frequency range: 1 GHz – 3 GHz
  • RF Input / Output: 50 Ohm, SMA female; DC supply: Mini-USB-C connector
  • Nominal supply Voltage: 5V, typ. 800mA; maximum supply voltage 5.5V.
  • Nominal input power: -10 dBm to – 8 dBm; maximum input power: -5 dBm continuous, -3 dBm max.
  • Operating temperature range: -20°C to 50°C

2uH Line Impedance Stabilization Network LISN – ECSS-E-ST-20-07C

Two-path 2 µH LISN for spacecraft-related conducted measurements based on ECSS-E-ST-20-07C.

  • LISN type: V-AMN, 50 ohm // 2 µH
  • Characterized frequency range: 10 Hz – 200 MHz
  • DC Resistance: 100 milliohm per path
  • Maximum current: 25 A continuous
  • Operating voltage range: 0 – 60V DC

50 µH 16 A LISN with Switchable RF Protection

  • Type — Single-phase 50 µH LISN for CISPR 16-1-2
  • Current — Up to 16 A at 23 °C, depending on socket. US NEMA 5-15: 15 A.
  • Operating voltage — Up to 250 V AC at 50/60 Hz or 250 V DC
  • Frequency — 9 kHz–30 MHz
  • Key feature — Line/neutral selector with switchable +6 dBm limiter, 10 dB attenuation, and 150 kHz–30 MHz high-pass filtering

Trans-conductance Amplifier / Current Injector

Four-quadrant transconductance amplifier and current injector for controlled low-frequency and RF current injection.

  • Frequency range: DC – 50 MHz, useable up to 100 MHz
  • Transconductance: 0.1 A/V, 1 A/V
  • Operating temperature range: -20°C to +40°C
  • Dimensions: W 300 mm x H 150 mm x L 270 mm;
  • Weight: 6.6 kg

0.5 Ohm Measuring Resistor

0.5-ohm measuring resistor for CS101 and related low-frequency conducted-immunity test arrangements.

  • Characterized frequency range: 10 Hz to 300 kHz
  • Maximum power rating: 100 W / 14 A continuous without forced convection 150 W / 17 A short time without forced convection 200 W / 20 A short time without forced convection
  • Connectors: 4 mm safety sockets
  • Earth: slotted aluminium brackets; 4 mm socket
  • Weight: 1.4 kg

Powerline Ripple Detector

Power-line ripple detector for monitoring injected disturbance amplitude during conducted-susceptibility testing.

  • Characterized frequency range: 10 Hz to 300 kHz
  • Insertion loss above 50 Hz: 80 dB ± 1 dB with toggle in “Flat response” position see frequency response plot for toggle switch in “CS101” position
  • Input voltage range: 100 V AC to 240 V AC; 100 V DC to 270 V DC
  • Maximum input voltage: 240 V AC, 270 V DC
  • Input connectors: 4 mm safety sockets

The TBMDA5 modulated amplifier provides the necessary power, bandwidth and modulation for conducted immunity testing using CDNs in the frequency range from 150 kHz to 400 MHz. It is designed to be driven by the tracking generator output of spectrum analyzers.

The TBMDA-BCI25 modulated amplifier provides the necessary bandwidth and modulation for conducted immunity testing using BCI probes per ISO 11452-4 in the frequency range from 1 MHz to 400 MHz.

Loading...