Categories

Langer ICS 105 | Compact IC workbench scanner

Langer ICS 105 | Compact IC workbench scanner

Langer FLS 106 IC | Large-area scanner with probe rotation

Langer FLS 106 IC | Large-area scanner with probe rotation

Langer FLS 106 PCB | Large-area three-axis PCB scanner

Langer FLS 106 PCB | Large-area three-axis PCB scanner

Langer Scanner and Scanner Probe Comparison Guide

Langer Scanner and Scanner Probe Comparison Guide

Langer LFS Scanner Probes | 100 kHz to 50 MHz

Langer LFS Scanner Probes | 100 kHz to 50 MHz

Langer RFS Scanner Probes | 30 MHz to 3 GHz

Langer RFS Scanner Probes | 30 MHz to 3 GHz

Langer XFS Scanner Probes | 30 MHz to 6 GHz

Langer XFS Scanner Probes | 30 MHz to 6 GHz

Products

Langer ICS 105 | Compact IC workbench scanner

50 x 50 x 50 mm; +/-180 deg | 10 um linear; 1 deg rotation | USB | 110/230 V | 23 kg; 350 x 400 x 420 mm

ICS 105 provides X/Y/Z travel and motorized probe rotation for automated near-field measurements above ICs and small assemblies. Its compact footprint and 10 um minimum linear step suit focused IC investigations. Add the appropriate ICR microprobe or passive scanner probe for the field and spatial scale being measured.

Langer FLS 106 IC | Large-area scanner with probe rotation

400 x 600 x 120 mm; +/-180 deg | 20 um linear; 1 deg rotation | USB | 110/230 V | 75 kg; 1030 x 775 x 900 mm

FLS 106 IC combines a 400 x 600 x 120 mm work area with motorized alpha rotation. It suits larger assemblies and fixtures while retaining angular positioning for IC near-field work. The platform can be configured for surface scans and localized ESD/EFT investigations with the required probes, field sources and generators.

Langer FLS 106 PCB | Large-area three-axis PCB scanner

400 x 600 x 120 mm; no alpha axis | 20 um linear | USB | 110/230 V | 75 kg; 1030 x 775 x 900 mm

FLS 106 PCB provides automated X/Y/Z positioning over a 400 x 600 x 120 mm area for repeatable PCB near-field maps. A digital microscope camera supports optical positioning. The published collision-protection function stops downward probe movement when contact is detected; it does not replace careful setup or all protective measures.

Langer Scanner and Scanner Probe Comparison Guide

3 scanner platforms | Full and Basic packages | 12 passive scanner probes

Compare travel, axes, minimum step, speed, footprint, field type, probe geometry and frequency range before configuring an EMC scanning system.

Langer LFS Scanner Probes | 100 kHz to 50 MHz

100 kHz to 50 MHz | 1 probe models | Passive | SMA connection

LFS-B 3 is a passive H-field scanner probe for low-frequency magnetic-field investigations. Its orthogonal coil and perpendicular approach help reach PCB structures between taller components.

Langer RFS Scanner Probes | 30 MHz to 3 GHz

30 MHz to 3 GHz | 7 probe models | Passive | SMA connection

RFS combines passive H-field and E-field scanner geometries for general PCB EMC development from 30 MHz to 3 GHz. Start with a larger-area probe to locate the source, then select a smaller head or electrode for the detailed scan.

Langer XFS Scanner Probes | 30 MHz to 6 GHz

30 MHz to 6 GHz | 4 probe models | Passive | SMA connection

XFS passive scanner probes extend PCB near-field investigations to 6 GHz. Choose an R or B magnetic geometry or a fine E-field electrode to suit the coupling path and access to the structure being measured.


Loading...