  • Frequency Range: 
    • Band 1:  20Hz - 10kHz

    • Band 2: 10kHz - 1MHz
    • Band 3: 1MHz - 30MHz
  • Frequency step:
    • Band 1:  20Hz/step
    • Band 2: 10kHz/step
    • Band 3: 500kHz/step
  • Includes: Generator, USB Cable, charger, storage box

  • Frequency Range: 
    • 100kHz - 400MHz for AC / DC LISN
    • 10MHz/100MHz - 7.5GHz
  • Frequency step: 
    • 100/500 kHz switchable for AC / DC LISN and Monopole Antenna
    • 10MHz/100MHz switchable for RE
  • Includes: Generator, Charger, Storage case

  • Frequency Range: 
    • 50kHz - 108MHz for AC / DC LISN
    • 50kHz - 30MHz with Monopole Antenna (CISPR 25)
    • 30MHz - 1GHz (10MHz steps)
    • 1 - 6GHz (100MHz steps)
  • Frequency step: 
    • 50/500 kHz switchable for AC / DC LISN and Monopole Antenna
    • 10MHz for 30MHz - 1GHz
    • 100MHz step for 1 - 6GHz
  • Includes: Generator, Charger, Storage case

  • Connector to DuT: 6 mm wing terminal including 4 mm banana jack
  • 150 kHz to 30 MHz
  • 220pF + 510 Ω RC Circuit
  • CISPR 16-1-2

Pyramidal standard gain horn Antenna optimized for far-field gain

  • 8 - 18 GHz
  • 20 dBi Gain

Pyramidal standard gain horn Antenna optimized for gain at 1 meter

  • 40 - 67 GHz
  • 15 - 18.5 dBi Gain

  • Acc. to CISPR 25 Ed. 4 or BMW GS 95025-1
  • impedance (5µH) || 50 Ohm
  • 70 A, 1000 V (DC)
  • Backside with built-in 0.1 microfarad capacitor to ground
  • N-jack

  • Conducted common mode immunity testing according to IEC 61000-4-6
  • Complies with CISPR 16-1-2
  • can be used for both emission and immunity testing

Diode Pulse Limiter with built-in 10 dB high power attenuator and fuse lamp to protect sensitive measuring equipment when measuring spectra with high energy. Thanks to the built-in fuse lamp, serious overload situations of sensitive equipment can be recognized fast and reliably. A replacement bulb is placed inside the unit. The pulse limiter prevents expensive equipment defects. The very flat frequency response allows high measurement accuracy, even if only a few sample values are used for correction.

Diode Pulse Limiter with built-in 20 dB high power attenuator and fuse lamp to protect sensitive measuring equipment when measuring spectra with high energy. Thanks to the built-in fuse lamp, serious overload situations of sensitive equipment can be recognized fast and reliably. A replacement bulb is placed inside the unit. The pulse limiter prevents expensive equipment defects. The very flat frequency response allows high measurement accuracy, even if only a few sample values are used for correction.