Standards

Products

PGESD 300K DP - Helicopter 300kV ESD Test System

  • High Voltage Capability: Generates electrostatic discharges up to 300 kV with reversible polarity.
  • Adjustable Electrode: Height adjustable from 1.5 to 6 meters and tilt up to ±60° for precise targeting.
  • Standards Compliance: Meets MIL-STD-331, MIL-STD-464, NATO AECTP-250, AECTP-500, and more.
  • Automated Operation: PC-based software for remote control, calibration, and test reporting.
  • Enhanced Safety: Fiber optic interface ensures operator safety by isolating the control system from high-voltage equipment.
  • Versatile Testing: Supports multiple discharge scenarios, including personnel-borne and helicopter-borne ESD tests.
  • Durable Design: Built for demanding military and industrial testing environments.

opto, Fiber-optic, Automotive Link Overview

Highlights of the CS116 Damped Sinusoid Generator

  • MIL-STD 461 CS115+CS116 Compliant: Meets stringent military testing standards.
  • Flexible Frequency Options: Choose from 6, 9, or 17 test frequencies.
  • Comprehensive Accessories: Includes injection probe, attenuator, oscilloscope, and control software.
  • Efficient Operation: Single signal output reduces test time and supports automation.
  • User-Friendly Control: Easily controlled via RS232 and USB interfaces.
  • Robust Design: Durable construction with wide power compatibility (90–264 Vac).

Optimize your naval and industrial testing with the CS116 & CS115 Damped Sinusoid & Switch Transient Generator—precision and efficiency combined.

  • Capability:
    • Spectral scan, spatial scan, peak-hold, continuous scanning, spectral and spatial comparison, scripting, limit lines, and report generation.
  • Spatial scan time:
    • Continuous real-time or sub-second single scan for the entire scan area is dependent on spectrum analyzer performance.
  • Spectral scan time:
    • 45 seconds for L 10 cm x W 10 cm (L 4” x W 4”) PCB with a 100 MHz span and 100 kHz RBW. Scanning area, span, and RBW are user-selectable within spectrum analyzer specifications
  • EMViewer Software
    • We recommend you use the EMViewer software for best results.  A Yearly subscription or a once-off purchase is available. 
  • Supported operating systems: Windows 10®
  • Supported CAD overlays: Standard Gerber© RS274x format and HPGL format

  • Protocol reports
  • Generation of waveforms with synchronous data acquisition 
  • Modular Expandable
  • Individual Waveform Generation
  • Standard Libraries included
  • Unlimited Waveform size
  • 2 different Waveforms synchronously 
  • DLL's for LabView, Vector CANoe / CAPL, C#, C++, ANSI C, Python, etc.
  • Simulation of imported oscilloscope waveform

  • DC - 200 kHz bandwidth DC 
  • MHz (small signal -3 dB)
  • Output voltage ±75 Vpk
  • Rise / fall time 100 V/µs
  • USB interface standard, LAN optional
  • Analog control input 0 ... ±10 V for control of voltage and current
  • Monitor outputs for measured voltage and current values (not all models)
  • Modularly extensible via master-slave mode
  • Parallel and Series Connections for two or more units

The fiber connector cleaning kit allows for cleansing the fiber optic connector to ensure reliable operation of the LSProbes and other Fiber optic products.

The Schwazbeck Biconical elements come in many sizes and offer different performances depending on what your needs are. For best low-frequency performance (good gain, low antenna factor), larger elements work better. The downfall of larger elements is handling or fitting in the test space. Many situations may not need outstanding performance with larger elements. The benefits of these elements and antenna baluns are that they all use the same connections (10mm), allowing for versatile sharing/switching of elements. No need to purchase a new antenna; get new elements.

 

The CDG 7000 is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields - including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, an RF power amplifier, a 3-channel RF voltmeter, and a directional coupler at a very affordable price. IEC 60601-1-2 calling out IEC 61000-4-39 magnetic immunity for close proximity testing requirements can also now be met with the 10 kHz unit. 

  • Advanced Ripple Testing: Meets ISO 21498, LV123, VW 80300, Nissan MES PW 67602, Mazda, and emerging standards.
  • Series Amplifier Integration: High accuracy ripple injection, minimal distortion, and enhanced safety.
  • Waveform Versatility: Sine, square, trapezoidal, pulses, and triangle waveform generation.
  • WaveMaster Software: Fast DUT impedance measurement, automated test sequences, and dynamic voltage/current control.
  • High Power Capability: Ripple Voltage up to 100 Vpp, currents from 100A to 2000A+, and frequency range 10 Hz–300+ kHz.
  • Future-Proof Design: Modular architecture for easy upgrades and adaptation to new standards.

Loading...