Standards

Products

Matched test clamp for DCS05 Test Generator, the Generator produces damped oscillatory wave transients in the frequency range 500kHz to 50 MHz that meet the definition of a type 1N Generator verification requirements Defence Standard 59-411.  9 Fixed frequencies are available: 500 kHz, 1 MHz, 2 MHz, 3 MHz, 5 MHz, 10 MHz, 15 MHz, 35 MHz, and 50 MHz. 

  • Small biconical microwave antenna
  • (1) 3 - 18 GHz
  • Compliant with CISPR 16-1-4 for site validation above 1 GHz
  • Including transport case
  • 10 W

The optoUART system can be used for the optical transmission of UART-signals up to a data rate of 1 Mbit/s.

It can be used to transmit UART-signals over long distances or to handle ground potential problems. With the optical transmission and the shielded case, the system is well equipped for EMI and EME tests.

ptoTTL 5-3-u is used for the optical transmission of TTL (Transistor-Transistor Logic) 3.5 & 5 V TTL signals digital signals. Up to 16 digital signals with a sampling rate of 40 MS/s (each channel) can be transmitted. The system consists of a transmitter supplied by batteries, a simplex-62,5/125µm-multimode optical cable, and a receiver – which has integrated batteries as well.

The LSProbe 1.2 Variant F Field Probe is a high-speed, high-accuracy, and high-dynamic range electric-Field probe.

  • Its standard frequency range of 10 Hz – 8.2 GHz. 1,000 V/m
  • Best-in-class compensation of linearity, frequency, and temperature guarantees accurate measurements from less than 0.1 to at least 1,000 V/m.
  • A dynamic range of 100 dB is achieved for many frequencies, enabling Field measurements at more than 10,000 V/m.
  • Customized high Field-strength „X“-variants, supporting up to 30,000 V/m and a damage level of 100,000 V/m, are available upon request.

The optoSENT system was developed for the transmission of asynchronous SENT signals (Single Edge Nibble Transfer) and exists in two different versions.

The LSProbe 1.2 Variant E Field Probe is a high-speed, high-accuracy, and high-dynamic range electric-Field probe.

  • Its standard frequency range of 10 kHz – 8.2 GHz. 15,000 V/m
  • Best-in-class compensation of linearity, frequency, and temperature guarantees accurate measurements from less than 15 to at least 15,000 V/m.
  • A dynamic range of 100 dB is achieved for many frequencies, enabling Field measurements at more than 10,000 V/m.
  • Customized high Field-strength „X“-variants, supporting up to 30,000 V/m and a damage level of 100,000 V/m, are available upon request.

Stacked Logarithmic-Periodic Broadband Antenna for Linear polarised RX- and TX- applications in the microwave frequency range. The antenna structure is made of laser-cut brass. For the protection of the fine antenna structure against damage, the antenna is equipped with a low loss plastic protection cover. The STLP 9149 is especially suitable for Immunity Testing acc. to IEC 61000-4-3 because of its good field uniformity.

  • (0.6)0.7-9 (10.5) GHz
  • Gain 10.3 dBi +/- 1.5 dBi
  • Type N female

  • Wideband Precision (9 kHz – 30 MHz): Delivers ±1 dB antenna factor stability across the full frequency range.
  • Long-Life, Low?Noise Operation: Internal NiMH battery pack provides >12 hours of noise-free measurements.
  • Dual-Field Capability: Supports both magnetic (–31.5 dB Ω·m) and “fictive” electric (20 dB/m) field measurements with one probe.
  • Rugged, User-Friendly Design: Milled aluminum housing with LED overload indicator and versatile tripod or handle mounting.

 

  • 8 kHz – 30 MHz Wideband: Delivers ±1 dB antenna-factor accuracy across the full spectrum.
  • Dual-Mode Measurement: 20 dB/m (E-field) and –31.5 dB Ω·m (H-field) in one compact probe.
  • Long-Life Battery Operation: NiMH pack provides over 12 hours of low-noise, mains-free measurements.
  • Overload Protection: Built-in LED indicator alerts you at the 1 dB compression point.

 