DGA 9552 N is a bidirectional attenuator, i.e. the attenuation and power capability specification is valid for both directions.

There is a large variety of applications for this attenuator: The measuring range of a spectrum analyzer can be increased. Any kind of meter can be protected against overload; it can be used to control the linearity of a meter reading. It can minimize measurement uncertainty caused by mismatched impedances. During an EMI receiver calibration, an attenuator directly at the pulse generator output is inevitable.

  • 3, 6, 10, 20, 30, and 40 dB Values available
  • 50 Ohm, Low VSWR
  • 5 Watts, 1 kW peak (5 μsec. pulse width, 0.25% duty cycle)
  • Optional storage case CCA

DGA 9553 BNC is a bidirectional attenuator, i.e. the attenuation and power capability specification is valid for both directions.

There is a large variety of applications for this attenuator: The measuring range of a spectrum analyzer can be increased. Any kind of meter can be protected against overload; it can be used to control the linearity of a meter reading. It can minimize measurement uncertainty caused by mismatched impedances. During an EMI receiver calibration, an attenuator directly at the pulse generator output is inevitable.

  • 3, 6, 10, 20, and 30 dB Values available
  • 50 Ohm, Low VSWR
  • 1 Watts

Gtemcell offers an innovative shielding product made of a highly conductive double layer of aluminum with internal reinforcing mesh in polyester for the coating and creation of shielded environments within pre-existing structures.  The application frequencies range from a few Mega Hertz to several GHz with an electric field attenuation of 45-80dB. The great advantage is ease of application even on curved and complex surfaces and lower costs which make this application particularly attractive. GTEMCELL supplies the shielded fabric or performs all the environmental shielding work. The aesthetic finishes are the responsibility of the customer.
The construction includes a preliminary inspection to evaluate all the "critical" aspects such as the openings present: doors. windows, air conditioning systems, electrical connections and consequently draw up an economic evaluation of the costs.

Linear polarized Stacked Logarithmic Periodic Broadband Antenna with N- or 7/16connector for Receive and Transmit Applications. Main Application: Generation of defined field strength levels for radiated immunity testing. Further the cross-polar rejection of the STLP 9128 F is excellent.

  • 70 MHz to 1.5 GHz
  • gain of 8.6 dBi, ripple of less than +/- 2.3 dB
  • Type N female or Type 7/16 female

The Conformity Assessment Business Model DCS05 Test Generator. When coupled to its matched test clamp, the Generator produces damped oscillatory wave transients in the frequency range 500kHz to 50 MHz that meet the definition of a type 1N Generator verification requirements Defence Standard 59-411.  9 Fixed frequencies are available: 500 kHz, 1 MHz, 2 MHz, 3 MHz, 5 MHz, 10 MHz, 15 MHz, 35 MHz, and 50 MHz. 

Matched test clamp for DCS05 Test Generator, the Generator produces damped oscillatory wave transients in the frequency range 500kHz to 50 MHz that meet the definition of a type 1N Generator verification requirements Defence Standard 59-411.  9 Fixed frequencies are available: 500 kHz, 1 MHz, 2 MHz, 3 MHz, 5 MHz, 10 MHz, 15 MHz, 35 MHz, and 50 MHz. 

The optoUART system can be used for the optical transmission of UART-signals up to a data rate of 1 Mbit/s.

It can be used to transmit UART-signals over long distances or to handle ground potential problems. With the optical transmission and the shielded case, the system is well equipped for EMI and EME tests.

ptoTTL 5-3-u is used for the optical transmission of TTL (Transistor-Transistor Logic) 3.5 & 5 V TTL signals digital signals. Up to 16 digital signals with a sampling rate of 40 MS/s (each channel) can be transmitted. The system consists of a transmitter supplied by batteries, a simplex-62,5/125µm-multimode optical cable, and a receiver – which has integrated batteries as well.

The LSProbe 1.2 Variant F Field Probe is a high-speed, high-accuracy, and high-dynamic range electric-Field probe.

  • Its standard frequency range of 10 Hz – 8.2 GHz. 1,000 V/m
  • Best-in-class compensation of linearity, frequency, and temperature guarantees accurate measurements from less than 0.1 to at least 1,000 V/m.
  • A dynamic range of 100 dB is achieved for many frequencies, enabling Field measurements at more than 10,000 V/m.
  • Customized high Field-strength „X“-variants, supporting up to 30,000 V/m and a damage level of 100,000 V/m, are available upon request.

The LSProbe 1.2 Variant E Field Probe is a high-speed, high-accuracy, and high-dynamic range electric-Field probe.

  • Its standard frequency range of 10 kHz – 8.2 GHz. 15,000 V/m
  • Best-in-class compensation of linearity, frequency, and temperature guarantees accurate measurements from less than 15 to at least 15,000 V/m.
  • A dynamic range of 100 dB is achieved for many frequencies, enabling Field measurements at more than 10,000 V/m.
  • Customized high Field-strength „X“-variants, supporting up to 30,000 V/m and a damage level of 100,000 V/m, are available upon request.