HV - Impulse generators IPG 620, IPG 1050 and IPG 1272 create standard impulse voltages with waveform 1.2 / 50 µs acc. to IEC 60. The generators simulate surges caused by switching of inductive loads, power system switching, lightning strokes, etc. They are designed for testing of impulse dielectric strength of components, insulation, air-and surface flash-over gaps as well as for testing surge immunity of devices and systems acc. to CCITT - K22, ITU-T-K44. Picture: incl. option PA503
The GTEMCELL GTEM-1000 Family is a TEM waveguide with the upper-frequency limit extended to the GHz range. It is under consideration as an alternative measurement facility for both radiated emission and immunity measurements. It is included in the standard IEC 61000-4-20 “Emission and Immunity Testing in Transverse Electromagnetic (TEM) Waveguides”.
Model GTEMCELL GTEM250 F with Ferrite tiles on the bottom offers a wider operating bandwidth with peak smoothed and flat response starting from DC to microwave frequencies. It is an indispensable tool for researchers and developers engineers! Model GTEMCELL GTEM250 F SAE includes a special opening to test integrated circuits, dimensions: 80 mm x 80 mm on Approx. 45 mm septum height, closed from a removable panel where are placed the IC under testing.
The GTEMCELL GTEM 400 family consist of the: GTEM-400 made with 65cm pyramidal carbon-foam absorbers (RAM). GTEM-450 made with 51cm. EMC Truncated pyramidal absorbers (RAM) GTEM-450V is the vertical model (suffix V) made with 51cm. EMC Truncated pyramidal absorbers (RAM)
GTEM-500 F made with Ferrite tiles on the bottom and 45cm Hybrid pyramidal carbon-foam absorbers (RAM). GTEM-550 F made with Ferrite tiles on the bottom and 35cm Hybrid pyramidal carbon-foam absorbers (RAM). GTEM-550 VF is the vertical model (suffix V) made with Ferrite tiles on the bottom and 35cm Hybrid pyramidal carbon-foam absorbers (RAM).
The GTEMCELL GTEM-750/800 is a TEM waveguide with the upper-frequency limit extended to the GHz range. It is under consideration as an alternative measurement facility for both radiated emission and immunity measurements. It is included in the standard IEC 61000-4-20 “Emission and Immunity Testing in Transverse Electromagnetic (TEM) Waveguides”.
Highly accurate reference for antenna calibrations, site validations, and EMC conformance tests according to ANSI C63.4, ANSI C63.5, CISPR 16-1, CISPR/A/244/FDIS Uncertainty in the antenna factors: less than 0.15 dB (95.5%) at the resonance frequency
Highly Accurate Reference Antenna for Site validation measurements according to CISPR 16-1-4 in fully anechoic rooms
STLP 9128 E - Stacked Log Periodic Antenna