Standards

Products

The LSProbe 2.0 Variant B Field Probe is a high-speed, high-accuracy, and high-dynamic range electric-field probe.

  • Its standard frequency range is 9 kHz – 26.5 GHz. (Variant B) 1,000 V/m
  • Best-in-class compensation of linearity, frequency, and temperature guarantees accurate measurements from less than 1 to at least 1,000 V/m.
  • A dynamic range of 100 dB is achieved for many frequencies, enabling Field measurements at more than 10,000 V/m.

  •  Up to 10 GHz – Wideband pulsed field measurement
  •  High Accuracy – Captures fast transients
  •  Passive Operation – No power needed
  •  EMI Immune – Interference-free data
  •  Oscilloscope Ready – Direct coaxial output
  •  Rugged Design – Built for harsh environments

  •  Up to 10 GHz – Wideband pulsed field measurement
  •  High Accuracy – Captures fast transients
  •  Passive Operation – No power needed
  •  EMI Immune – Interference-free data
  •  Oscilloscope Ready – Direct coaxial output
  •  Rugged Design – Built for harsh environments

The MF EASY is a scalable and flexible multichannel measurement and assessment system for magnetic fields in the frequency range DC – 400 kHz. It is available with 5 or 10 (on request up to 15) fully isotropic measurement channels enabling simultaneous magnetic field measurements on 5 or 10 (15) measurement positions.

Different standard probe types (sizes and shapes) are available for the MF EASY. Customized probes are available on request. Iso-centrically arranged coil and Hall sensor enable a measurement frequency range from DC to 400 kHz and a measurement sensitivity suitable for assessing human exposure.

High-Frequency Transmit Coil (CAB4-3910)

  • Frequency: 150 kHz to 26 MHz
  • Main Diameter: 100 mm
  • Number of Turns: 3
  • Wire Diameter: 1mm
  • Connection type: ‘N’ type Coaxial

High-Frequency Sense Coil (CABLSHF)

 

  • Frequency: 150 kHz to 26 MHz
  • Diameter to center of the coil: 41 mm
  • Number of turns: 1
  • Wire type: 1mm single core
  • Winding Type: Electrostatically shielded

U-DC

  • High-resolution (16 bit)
  • Measurement Display
  • +/-60V input; +/- 6V or +/-12V output (customizable)
  • Up to 40 samples / s (remote access, moving mean mode, programmable)
  • Multi-channel receiver with Display and remote data access via USB, GPIB,...

  • The circular transmitting loop antenna
  • 0.01 - 120 MHz
  • diam. 100 mm
  • turns 3
  • BNC Connectors 

The ESD Test Table Kit is a simple inexpensive solution for your ESD testing. Complies to the requirements of IEC 61000-4-2 and can be used for additional standards. Comes with a Horizontal Coupling Plane (HCP), resistive cable to tie HCP to floor ground plane, bleeder wire for discharging ungrounded battery powered EUTs, 0.05mm insulator and an alternative low impedance ground for using the table for additional setups such as IEC 61000-4-6 requirements.

The STLP 9129 was specially designed for wideband immunity tests. This unrivaled bandwidth was achieved by combining both well-proven antenna designs STLP 9128 D and the STLP 9149. The STLP 9129 does provide the optimum out of gain and field uniformity at the same time as well as both basic antennas do. Main Application: Generation of defined high field strength levels for radiated immunity testing acc. IEC 61000-4-3.

  • 70 MHz to 10 GHz
  • gain of 8.6 dBi, ripple of less than +/- 2.3 dB
  • Type N female or Type 7/16 female

The EMC test system is designed for testing electromagnetic immunity of the electrical installation of vehicles and components against supply line transients. EMC - Test Equipment for the electrical installation of vehicles.

  • Pulse  #1 1-5/2000us, 600 V
  •          #1 1-5/1000us, 600 V
  • Pulse #2a 1 / 50us, 600 V
  • Pulse #3 5/100 ns, 800 V