U-DC Single channel w/multichannel receiver 17Bit, 60V, 10Hz

U-DC

  • High-resolution (16 bit)
  • Measurement Display
  • +/-60V input; +/- 6V or +/-12V output (customizable)
  • Up to 40 samples / s (remote access, moving mean mode, programmable)
  • Multi-channel receiver with Display and remote data access via USB, GPIB,...

MARKETS:

TEST STANDARDS:

SPECIFICATIONS

U-DC Single channel w/multichannel receiver 17Bit, 60V, 10Hz


The U-DC system is a unique product that makes measuring DC voltages easier. With an integrated display and output, additional measurement devices are not required. Up to 8 channels can be integrated into the 19" rack-mount receiver (outside the chamber), and each channel is attached to its own transmitter block. This system is ideal for accurately measuring voltages, and a fast response is unnecessary. The response time is 10Hz. Alternatively, the Ux/14 analog measurement device can be used. 

   Go to our quick guide for all mk messtechnik fiberoptic links

 

A Quoted kit will consist of the following configuration:

U-DC    DC optical transmission of analog signals
                   up to 8 DC channels, resolution min. 17 bit, response time is 10Hz

1x 19" U-DC base unit

  • 19" rack mount base unit with external power supply.
  • size: 2HU for up to 8 U-DC 19" receiver channels, to be used outside ALC

1x PS120-2f-DC

  • external power supply (only for CR use; not for use inside ALC during EMC-tests!)
  • input: 100 .. 240 VAC; 50 .. 60 Hz;
  • output: 12 V/x A (adjusted to necessary value)
  • connector: 2-pole female DC connector,
  • US Plug standard

1x HMI-2-L

  • display for 19" 2HU sensor base units (takes 4 slots width)
  • up to 4 channels can be displayed on one page, and push buttons to switch to the next page (sensors 1-4, 5-8, ..)

1x 19" interface module

  • interface module for U-DC 19" or U1/14-30M 19" base unit (takes one slot width)
  • including RS232, USB, GPIB
  • Maximum transfer rates:
  • buffered mode, non-HS488: 1.05 Mbytes/s
  • HS488 handshake: 2.2 Mbytes/s
  • unbuffered mode: 200 kbytes/s
  • optical connector: FSMA

1x 19" interface module - HW option ethernet

  • ethernet interface module extension for 19" interface module (of U-DC base unit) to be able to gather data via ethernet port
  • 19" interface module mandatory as base

#x U-DC 19" (select Number of Channels) 

  • +/-60 V digital voltmeter with ~17 bit resolution (~1 mV) and transmission via optical interface;
  • max. error at display ~0,1% of measured value
  • max. error at analog out ~0,2% of measured value
  • sampling rate approx. 10 Hz
  • moving mean mode (1 to 25 samples) to reduce noise can be programmed
  • 19" U-DC base unit mandatory
  • Below items 1 per channel

1x U-DC transmitter

  • digital voltmeter with optical interface
  • Input: +/-60 V DC
  • connector: BNC
  • optical connector: 1x FSMA
  • integrated NiMH batteries: 5 cells, 6 V/4 Ah
  • battery run time: >40 h
  • charge connector: female 5 pole Binder 712 (prepared for external supply)
  • shielded aluminum housing

1x U-DC receiver 19"

  • digital voltmeter receiver with optical interface
  • Output: +/-12 V DC (5:1 divider output from transmitter, calculate x5 at oscilloscope)
  • connector: BNC
  • optical connector: 1x FSMA
  • plug-in board with front panel for 19“ rack mount base unit

1x FI-1-10k-BNC-Bessel

  • external input filter to be used for EMS/EME-testing with U-DC (BNC)
  • connectors: BNC
  • cutoff frequency (-3 dB): 10 kHz
  • division ratio: 1:1

1x LWL-1-20m-[FSMA]-OM1_625-[FSMA]

  • simplex optical fiber, cable type: OM1, multimode, 62,5/125 μm
  • connector side 1: FSMA male (metal), connector side 2: FSMA male (metal)
  • total length: 20 m

2x CH-1-5m standard plug-in charger

  • number of cells: 4 .. 10 NiMH/NiCd cells up to 5 Ah
  • AC-input: 100-240 V, charge current: 600-800 mA, charge connector: 5 pole male
  • ***AC-plug: Type A (US), others on request

#x U-DC multipoint calibration

  • multipoint calibration over the specified voltage range to make signal transmission more precise
  • valid for one channel
  • the goal of error: <<0,2% over the whole voltage range (standard calibration done at 30V, max error ~0,2% of measured value)

 

 

 