Standards

Products

  • Capability:
    • Spectral scan, spatial scan, peak-hold, continuous scanning, spectral and spatial comparison, scripting, limit lines, report generation, and notes.
    • Customization of the robot arm size, any size, is possible. 
  • Spatial scan time:
    • The scan time depends on size and area
  • Ideal for large component boards
    • The robotic arm allows for advanced scans on complex items
  • Supported operating systems: Windows 10®
  • Supported overlays: Picture in JPEG format 
  • Standard Gerber© RS274x format and HPGL form

Audio Transformer 200W, 50A

  • 160x155x200mm
  • 2:1 ratio 
  • 200 W Maximum30Hz - 250 kHz
  • 100 W Maximum at15 Hz - 30 Hz
  • Insulation Resistance Test - 2kV

  • Covers 1–18 GHz with programmable frequency steps
  • Delivers flat, stable signals with HI/LO output options
  • Sequential signal generation for better dynamic range
  • Compatible with spectrum analyzers & EMI receivers
  • Battery-powered with 8-hour runtime and USB-C charging
  • Includes accredited calibration and supports ISO 17025 compliance

 

Highlights of the CS116 Damped Sinusoid Generator

  • MIL-STD 461 CS115+CS116 Compliant: Meets stringent military testing standards.
  • Flexible Frequency Options: Choose from 6, 9, or 17 test frequencies.
  • Comprehensive Accessories: Includes injection probe, attenuator, oscilloscope, and control software.
  • Efficient Operation: Single signal output reduces test time and supports automation.
  • User-Friendly Control: Easily controlled via RS232 and USB interfaces.
  • Robust Design: Durable construction with wide power compatibility (90–264 Vac).

Optimize your naval and industrial testing with the CS116 & CS115 Damped Sinusoid & Switch Transient Generator—precision and efficiency combined.

PEFT 8010 

  • EFT/Burst
  • Up to 7.3kV (6.6kV at CDN)
  • CDN: 264V-AC 16-440Hz, 125V-DC
  • CDN: 16A-AC @ 50-60Hz, 10A-AC @ 400Hz, 16A-DC

  • Capability:
    • Spectral scan, spatial scan, peak-hold, continuous scanning, spectral and spatial comparison, scripting, limit lines, and report generation.
  • Spatial scan time:
    • Continuous real-time or sub-second single scan for the entire scan area is dependent on spectrum analyzer performance.
  • Spectral scan time:
    • 45 seconds for L 10 cm x W 10 cm (L 4” x W 4”) PCB with a 100 MHz span and 100 kHz RBW. Scanning area, span, and RBW are user-selectable within spectrum analyzer specifications
  • EMViewer Software
    • We recommend you use the EMViewer software for best results.  A Yearly subscription or a once-off purchase is available. 
  • Supported operating systems: Windows 10®
  • Supported CAD overlays: Standard Gerber© RS274x format and HPGL format

By Frequency Range

Axos 8 - Compact

  • Multi Tester with 16AMP CDN
  • EFT/Burst 5kV IEC 61000-4-4
  • Surge, Combination Wave 7kV IEC 61000-4-5
  • Surge Magnetic field IEC 61000-4-9 (MSURGE-A loop antenna required)
  • Ring Wave, 7kV IEC 61000-4-12 & ANSI
  • Telicomm Wave, 7kV IEC 61000-4-5 & ITU
  • AC Dips/Drops IEC 61000-4-11 (DIP 116 dips transformer required)
  • DC Dips/Drops IEC 61000-4-29 (2x DC supplies required)

Axos 5 - Compact

  • Multi Tester with 16AMP CDN
  • EFT/Burst 5kV IEC 61000-4-4
  • Surge, Combination Wave 5kV IEC 61000-4-5
  • Surge Magnetic field IEC 61000-4-9 (MSURGE-A loop antenna required)
  • AC Dips/Drops IEC 61000-4-11 (DIP 116 dips transformer required)
  • DC Dips/Drops IEC 61000-4-29 (2x DC supplies required)

" An RF Probe Kit on Steroids"

  • Fully integrated with Y.I.C. Technologies EMViewer software and EMProbe
  • Normalization and correction when using the EMViewer software
  • Flat response within the range of operation
  • Slim Design and Protective Coating
  • 18GHz Measured Cable included
  • Lectures & Explanation Document