EM-Clamp Calibration Fixture
Calibration fixture for EM-clamp common-mode impedance verification using the IEC/EN 61000-4-6 procedure.
MARKETS:
CATEGORIES:
TEST STANDARDS:
Calibration fixture for EM-clamp common-mode impedance verification using the IEC/EN 61000-4-6 procedure.
| Compliance | IEC/EN 61000-4-6, Annex A |
| Nominal frequency range | 150 kHz – 80 MHz |
| Usable frequency range | 10 kHz – 1 GHz |
| Nominal impedance | 248 ? |
| Impedance range | ~ 230? – 260 ? |
| RF connectors | N-Female |
| Center conductor height | adjustable, ~ 47 mm – 75 mm |
| Center conductor material | ? 4 mm, brass, nickel gold plated |
| Spacing between brackets | 652 mm |
| Ground plane dimensions | 1066 x 500 mm |
| Panel material | Aluminium 6061 |
| Weight | 6.5 kg |