EMI Camera for Low Emission / High Field Use

  • 30x Optical Zoom
  • Low light uses 0,05 lux (day) and 0,005 lux (night)
  • Integrated microphone 
  • Battery or wall-powered
  • Single Fiber operation (duel direction)
  • Local controls on back (zoom/pan/tilt/focus/..)
  • Options for Pan/Tilt, Joystick, HIRF, recording, motion triggering, OCR, ...

The LSProbe 2.0 Variant A Field Probe is a high-speed, high-accuracy, and high-dynamic range electric-field probe.

  • Its standard frequency range of 9 kHz – 18 GHz. 1,000 V/m
  • Best-in-class compensation of linearity, frequency, and temperature guarantees accurate measurements from less than 1 to at least 1,000 V/m.
  • A dynamic range of 100 dB is achieved for many frequencies, enabling Field measurements at more than 10,000 V/m.

The STLP 9129 Special was specially designed for wideband immunity tests. This unrivaled bandwidth was achieved by combining both well-proven antenna designs STLP 9128 D and STLP 9149. The STLP 9129 Special does provide the optimum gain and field uniformity at the same time, as well as both basic antennas, do. Main Application: Generation of defined high field strength levels for radiated immunity testing acc. IEC 61000-4-3.

  • 70 MHz to 10 GHz
  • gain of 8.6 dBi, ripple of less than +/- 2.3 dB
  • Type N female or Type 7/16 female

    • Technologically advanced, fast-switching, compact 19-inch power supplies
    • High control dynamics in the 100...200 µs range – even at higher power levels
    • Exceptional current accuracy of <0.02% FS, additional high-resolution current measurement range included as standard
    • Full power regeneration and a high degree of efficiency, resulting in a significant reduction of energy consumption and heat dissipation, low acoustic noise
    • Wide current-voltage range with an auto-ranging factor of 3
    • Full digital CV, CC, CP, CR, and Ri-Sim control modes

 

  • Full compliant system meeting the requirements 
  • IEC 61000-3-2 Harmoinc Emissions
  • IEC 61000-3-3 Flicker Emissons
  • USB controlled, Windows 10 compatible software included
  • 16 Amp, 120, and 230 Voltages, 50/60Hz

  • Full compliant system meeting the requirements 
  • IEC 61000-3-2 Harmoinc Emissions
  • IEC 61000-3-3 Flicker Emissons
  • USB controlled, Windows 10 compatible software included
  • 16 Amp, 120, and 230 Voltages, 50/60Hz

TRILOG Broadband Antenna, Combination antenna, Bicon+Log

  • 30 MHz to 7 GHz
  • 100 Watts
  • Ideal Broadband antenna for Emissions measurements to CISPR 16 and many others

Low-Frequency Transmit Coil (CAB4-3912)

  • Frequency: 9 kHz to 150 kHz
  • Main Diameter: 120 mm
  • Maximum Current: 15 A
  • Number of turns: 20

Low-Frequency Sense Coil (CABLSLF) 

  • Frequency: 9 kHz to 150 kHz
  • Diameter to center of the coil: 40 mm
  • Number of turns: 51
  • Wire type: 7/41 LITZ
  • Winding Type: Electrostatically shielded

The CAR-PFS-80 is an automotive power fail simulator, which is designed for performing fast voltage dips and drops (micro-interruptions) according to standard requirements, mainly from vehicle manufacturers. The electronic switches in the generator allow switching times below 1 microsecond.

The Wood Test Table is a simple, inexpensive solution for your EMC testing. The table is built to be ship flattened to reduce shipping costs and easily assembled on site quickly. The picture is shown with a ground plane.