HFa-1S, 16 Amp single phase Harmonics and Flicker
- 16 bit USB based data acquisition – works with Laptops & Desktop PC’s
- Very accurate Windows-7, 8, 10 compatible power analyzer with data storage
- Advanced reporting, data storage & replay features
- Control for most power sources incl. Ametek© Pacific Power© Teseq© etc.
- ISO-17025 Accredited Calibration with detailed data available
- Built-in Reference Impedance per IECTR 60725 available
- Small form factor works with 120 & 220/230 public power supply
Compliant too:
- IEC 61000-3-2 Ed. 3.2 & Ed. 5.0
- IEC 61000-3-3 Ed. 1.2 and 3.0
- Including: GB/T 14549 for China, NMX-J-550/3-2 for Mexico, JIS-C 61000-3-2 : 2019 for Japan, and GB 17625.2-2007 for China
Specifications
Electrical |
|
The frequency range of the fundamental line component |
45 – 65 Hz |
Sampling method |
PLL based with 512 samples/cycle (simultaneous per channel), or fixed frequency sampling |
Harmonic analysis range |
up to harmonic order 200 (10/12 kHz) |
Harmonic spectrum display |
up to harmonic 40, can be expanded to 9 kHz |
Voltage input range |
0 – 350 V-rms, + / - 500 Volt peak std, 500 V-rms optional |
Voltage measurement accuracy |
0.1 % + 10 mV, Voltage harmonics; 0.1 % + 0.1 % per 100 Hz + 5 mV |
Current input range |
0 – 20 A-rms |
Current measurement accuracy |
0.1 % + 5 mA in Phase-A, 0.15 % + 5 mA for Phase-B & C of 3 phase units |
Harmonic current accuracy |
0.1 % + 0.02 %/100 Hz+5 mA |
Power Factor range & accuracy |
-1.000 – 0 - +1.000, +/- 0.003 |
Power measurement |
– 20000 VA / 1 – 20000 Watt, per phase, measurement accuracy; 0.15% + 0.1 Watt |
Phase measurement range |
0 – 360 °, Phase accuracy 50 – 2500 Hz; 0.2° + 0.2° per100 Hz |
EUT interface Standard version |
IEC plug |
|
Optional IEC 60725 Reference Impedance can be built-in (must be ordered separately). |
Mechanical, input power & interface |
|
Dimensions |
7” x 7.5” x 2” (W x Lx H ) |
Input power |
100 – 240 Vac 50/60 Hz, max 50 Watt |
Interface |
USB type B |
Matching programmable AC power sources available for quote,
- 1200 kVA, 1Ø Output, 150/300 Voltage ranges, 10/5 A Current, 1Ø Input, 3U Height, 80lb./36.3kg Weight
- 4000 kVA, 1Ø Output, 135/270 Voltage ranges, 32/16 A Current, 3Ø Input, 8U Height, 185lb./84.0kg Weight
*Existing AC sources can be used from Ametek, Teseq, California Instruments, Chroma, Pacific Power, and others. please check with us.
|