The High-Voltage Pulse Generator Type PG 6-401 is designed for dielectric testing of X- and Y-capacitors with standard impulse voltages 1.6/47 µs up to 6 kV acc. to IEC 384-14, etc. The generator has the same principle of operation as the IPG 809 but allows testing capacitance values of 33 nF - 470 nF. Picture: incl. Option PA 503
The pulse generator IPG 250 is designed for measuring the step response of high-impedance networks, for instance voltage dividers, oscilloscope probes etc. The generator excels by calibrated adjustment of output amplitude, short rise time and flat pulse top. The output pulse amplitude can be adjusted by use of a 10-turn potentiometer from 0 to 250 V. Positive and negative polarity can be selected.