Standards

Products

Matched test clamp for DCS05 Test Generator, the Generator produces damped oscillatory wave transients in the frequency range 500kHz to 50 MHz that meet the definition of a type 1N Generator verification requirements Defence Standard 59-411.  9 Fixed frequencies are available: 500 kHz, 1 MHz, 2 MHz, 3 MHz, 5 MHz, 10 MHz, 15 MHz, 35 MHz, and 50 MHz. 

The optoUART system can be used for the optical transmission of UART-signals up to a data rate of 1 Mbit/s.

It can be used to transmit UART-signals over long distances or to handle ground potential problems. With the optical transmission and the shielded case, the system is well equipped for EMI and EME tests.

  • Wideband Precision (9 kHz – 30 MHz): Delivers ±1 dB antenna factor stability across the full frequency range.
  • Long-Life, Low?Noise Operation: Internal NiMH battery pack provides >12 hours of noise-free measurements.
  • Dual-Field Capability: Supports both magnetic (–31.5 dB Ω·m) and “fictive” electric (20 dB/m) field measurements with one probe.
  • Rugged, User-Friendly Design: Milled aluminum housing with LED overload indicator and versatile tripod or handle mounting.

 

The optoSPI-HS system can be used for the bidirectional optical transmission of SPI signals with transmission rates of up to 1Mbit/s. It consists of two battery supplied transceivers connected to each other with an optical fiber. With the optical transmission of the shielded case and the external filter, the system is well equipped for EMI and EME tests.

Stacked Logarithmic-Periodic Broadband Antenna for Linear polarised RX- and TX- applications in the microwave frequency range. The antenna structure is made of laser-cut brass. For the protection of the fine antenna structure against damage, the antenna is equipped with a low loss plastic protection cover. The STLP 9149 is especially suitable for Immunity Testing acc. to IEC 61000-4-3 because of its good field uniformity.

  • (0.6)0.7-9 (10.5) GHz
  • Gain 10.3 dBi +/- 1.5 dBi
  • Type N female

opto1394 This system is used for the optical transmission of IEEE1394/Firewire-signals and can transmit data rates of up to 400 Mbit/s (800 Mbit/s at 1394b). The transmitter system consists of two similar transceivers supplied by batteries and a duplex-62,5/125µm-multimode optical cable. Due to its insensitivity against strong electromagnetic fields, the opto1394 is fit for tests of electromagnetic compatibility in EMC-test chambers, TEM-cells, and striplines. The system can also be used for the fail-proof transmission of signals across long distances.

ptoTTL 5-3-u is used for the optical transmission of TTL (Transistor-Transistor Logic) 3.5 & 5 V TTL signals digital signals. Up to 16 digital signals with a sampling rate of 40 MS/s (each channel) can be transmitted. The system consists of a transmitter supplied by batteries, a simplex-62,5/125µm-multimode optical cable, and a receiver – which has integrated batteries as well.

The coupling clamp CDN 2012 conforms exactly to the requirements of ISO 7637-3 and other standards, guaranteeing that tests are carried out in strict compliance with the standard. The CDN allows the fast nanosecond pulse bursts ( ISO 3a and 3b) to be injected in cable runs. Very high impedance signal lines are also to be found in vehicles on which the disruptive effects of ISO pulses 1 and 2 can also show up through capacitive coupling.

The LSProbe 1.2 Variant F Field Probe is a high-speed, high-accuracy, and high-dynamic range electric-Field probe.

  • Its standard frequency range of 10 Hz – 8.2 GHz. 1,000 V/m
  • Best-in-class compensation of linearity, frequency, and temperature guarantees accurate measurements from less than 0.1 to at least 1,000 V/m.
  • A dynamic range of 100 dB is achieved for many frequencies, enabling Field measurements at more than 10,000 V/m.
  • Customized high Field-strength „X“-variants, supporting up to 30,000 V/m and a damage level of 100,000 V/m, are available upon request.

The LSProbe 1.2 Variant E Field Probe is a high-speed, high-accuracy, and high-dynamic range electric-Field probe.

  • Its standard frequency range of 10 kHz – 8.2 GHz. 1,000 V/m
  • Best-in-class compensation of linearity, frequency, and temperature guarantees accurate measurements from less than 0.1 to at least 1,000 V/m.
  • A dynamic range of 100 dB is achieved for many frequencies, enabling Field measurements at more than 10,000 V/m.
  • Customized high Field-strength „X“-variants, supporting up to 30,000 V/m and a damage level of 100,000 V/m, are available upon request.

Loading...