The Conformity Assessment Business Model DCS05 Test Generator. When coupled to its matched test clamp, the Generator produces damped oscillatory wave transients in the frequency range 500kHz to 50 MHz that meet the definition of a type 1N Generator verification requirements Defence Standard 59-411. 9 Fixed frequencies are available: 500 kHz, 1 MHz, 2 MHz, 3 MHz, 5 MHz, 10 MHz, 15 MHz, 35 MHz, and 50 MHz.
The coupling clamp CDN 2012 conforms exactly to the requirements of ISO 7637-3 and other standards, guaranteeing that tests are carried out in strict compliance with the standard. The CDN allows the fast nanosecond pulse bursts ( ISO 3a and 3b) to be injected in cable runs. Very high impedance signal lines are also to be found in vehicles on which the disruptive effects of ISO pulses 1 and 2 can also show up through capacitive coupling.
DGA 9553 BNC is a bidirectional attenuator, i.e. the attenuation and power capability specification is valid for both directions.
There is a large variety of applications for this attenuator: The measuring range of a spectrum analyzer can be increased. Any kind of meter can be protected against overload; it can be used to control the linearity of a meter reading. It can minimize measurement uncertainty caused by mismatched impedances. During an EMI receiver calibration, an attenuator directly at the pulse generator output is inevitable.
The LSProbe 1.2 Variant E Field Probe is a high-speed, high-accuracy, and high-dynamic range electric-Field probe.
Broad-Band Horn Antenna
The Conformity Assessment Business Model DCS12 Test Generator meets all the DCS12 wave verification parameters for testing DC, single and three-phase equipment, that is source impedance and verification of damping and frequency when measured into a 10 Ω load. Output amplitude is software adjustable with permanent memory, should re-alignment be needed during calibration.
The Conformity Assessment Business Model DCS06 Test Generator has been designed to operate with its complementary injection clamp to fully meet the pulse requirements of DCS06 when tested into a 5? load. It operates from an intuitive touch screen interface and has full phase synchronization up to 800 Hz input frequency with 1-degree steps. It has been designed with future revisions of the test standard in mind.
GTEMCELL Ltda shielded chambers are built up as modular construction. Due to individual modules, any size of the chamber can be realized. Big chambers may require an outer supporting structure or alternatively, the shielding material can be attached directly to the building. Panels are manufactured of 2,0 mm thickness hot galvanized sheet steel double bordered.
Linear polarized Stacked Logarithmic Periodic Broadband Antenna with N- or 7/16connector for Receive and Transmit Applications. Main Application: Generation of defined field strength levels for radiated immunity testing. Further the cross-polar rejection of the STLP 9128 F is excellent.