Langer OSE Digital Optical Fiber Probes | 1, 2 and 4 Channels

DC to 50 Mbps | 1, 2 or 4 digital channels | S25 sensors | 5 V HCMOS BNC outputs

Compare OSE 150-1, OSE 150-2 and OSE 450 optical transmission sets for observing logic signals during EMC immunity testing. S25 sensor supply is 3 to 5 V at 30 mA. OSE 150 sets use individual OE 150 receivers; OSE 450 uses a single four-channel OE 450 receiver.

OSE 150-1 - Absolute EMC Datasheet

OSE 150-2 - Absolute EMC Datasheet

OSE 450 - Absolute EMC Datasheet

SPECIFICATIONS

OSE digital optical transmission sets

Select one, two or four digital channels for monitoring DUT logic during EMC testing. Each S25 sensor converts a signal to light and the receiver provides a 5 V HCMOS electrical output for the measuring instrument.

Specifications and included components

PhotoParameter / itemOSE 150-1 setOSE 150-2 setOSE 450 set
  Kit photograph OSE 150-1 set OSE 150-2 set OSE 450 set
  Digital channels 1 2 4
  Transmission range DC to 50 Mbps DC to 50 Mbps DC to 50 Mbps
  Receiver configuration 1 x OE 150 2 x OE 150 1 x four-channel OE 450
  Receiver electrical output BNC, 5 V HCMOS BNC, 5 V HCMOS 4 x BNC, 5 V HCMOS
  Receiver optical inputs 1 x diameter 2.2 mm 1 per receiver, diameter 2.2 mm 4 x diameter 2.2 mm
  Receiver supply 12 V / 100 mA 12 V / 100 mA 12 V / 100 mA
  S25 sensor supply 3 to 5 V, 30 mA per sensor 3 to 5 V, 30 mA per sensor 3 to 5 V, 30 mA per sensor
  S25 optical connector Diameter 2.2 mm Diameter 2.2 mm Diameter 2.2 mm
  Fiber operating length 1 to 20 m 1 to 20 m Confirm selected sensor / receiver configuration
OE 150 receiver OE 150 receiver 1 included 2 included -
OE 450 receiver OE 450 receiver - - 1 included
S25 optical sensor S25 optical sensor 1 included 2 included 4 included
Single optical fiber, diameter 2.2 mm Single optical fiber, diameter 2.2 mm 1 x 1.5 m 2 x 6 m 4 x 6 m
NT FRI EU power supply NT FRI EU power supply 1 included 1 included 1 included
Connection accessory tape Connection accessory tape 1 included 1 included 1 included
Connection sockets Connection sockets 3 included 6 included 8 included
  System case OSE 150-1 case OSE 150-2 case OSE 450 case
  Digital m user manual 1 included 1 included 1 included
  OSE 450 quick guide - - 1 included

Connect the optical measurement path

Connect the sensor at the DUT, route the optical fiber to the receiver, and connect the receiver to the measuring instrument. Provide the specified supply separately at each end. Keep the installed fiber length within the model-specific limit. Choose the sensor voltage range and channel count before configuring the test.

Optical signal transmission for EMC testing

Datasheets

Compare all Langer optical signal transmission sets

KitModelSignalChannels / directionBandwidth / data rateSampling / functionSupported fiber lengthIncluded fiber
A100-1 set A100-1 set Analog 1 DC to 25 kHz 125 ksps / 12 bit 1 to 20 m 1.5 m
A100-2 set A100-2 set Analog 2 DC to 25 kHz 125 ksps / 12 bit 1 to 20 m 2 x 6 m
A200-1 set A200-1 set Analog 1 DC to 500 kHz 3 Msps / 12 bit 1 to 20 m 1.5 m
A200-2 set A200-2 set Analog 2 DC to 500 kHz 3 Msps / 12 bit 1 to 20 m 2 x 6 m
A300-1 set A300-1 set Analog 1 DC to 5 MHz 12.5 Msps / 10 bit 1 to 20 m 1.5 m
A300-2 set A300-2 set Analog 2 DC to 5 MHz 12.5 Msps / 10 bit 1 to 20 m 2 x 6 m
OSE 150-1 set OSE 150-1 set Digital 1 DC to 50 Mbps Logic transmission 1 to 20 m 1.5 m
OSE 150-2 set OSE 150-2 set Digital 2 DC to 50 Mbps Logic transmission 1 to 20 m 2 x 6 m
OSE 450 set OSE 450 set Digital 4 DC to 50 Mbps Logic transmission See receiver / sensor configuration 4 x 6 m
CAN 100 set CAN 100 set CAN Bidirectional Up to 1 Mbit/s High-speed CAN 10 m maximum; 6 m at 1 Mbit/s Double 10 m
LIN 100 set LIN 100 set LIN Bidirectional LIN bus Master / slave Up to 20 m Double 10 m
OB 100 set OB 100 set CAN / LIN Bidirectional CAN / LIN selectable 2 Opto-Boxes 20 m; 6 m at 1 Mbit/s CAN Double 10 m
OTHER PRODUCTS IN THE SAME CATEGORY: