Langer OB 100 Set | CAN and LIN Opto-Box

CAN / LIN | Bidirectional optical transmission | 12 V supply; max. 25 V

OB 100 Set supports isolated bus connections for EMC testing. 20 m; 6 m at 1 Mbit/s CAN fiber limit. Includes Double 10 m optical fiber. See the specifications for the individual module supply and operating conditions.

OB 100 - Absolute EMC Datasheet

SPECIFICATIONS

OB 100 Set | CAN and LIN Opto-Box

Use two OB 100 Opto-Boxes to replace a section of an electrical CAN or LIN connection with fiber. The set also includes CAN 100 and LIN 100 probes for connecting close to the DUT.

Choose a configuration

KitVersionSignal bandwidth / rateIncluded fiber
OB 100 set OB 100 set CAN / LIN selectable Double 10 m

OB 100 set specifications

Parameter / componentSpecification
Operating time with charged internal batteries up to 1 week (depending on operating mode)
Supply voltage 12 V (max. 25 V)
max. current input at 12 V 250 mA (while charging internal battery)45 mA (without charging internal battery)
Optical fibre connector 2 x 2.2 mm Ø
Optical fibre length 20 m (6 m at 1 Mbit/s CAN)

OB 100 set included components

PhotoIncluded itemQty.
OB 100, Opto-Box 100 cropped from scope of delivery OB 100, Opto-Box 100 2x
CAN 100, Optical Fiber Probe cropped from scope of delivery CAN 100, Optical Fiber Probe 1x
Four-pole connection sockets Adapter Socket, 4-poles, Adapter Socket, 4-Pole 4x
LIN 100, Optical Fiber Probe cropped from scope of delivery LIN 100, Optical Fiber Probe 1x
Three-pole connection sockets Adapter Socket, 3-poles, Adapter Socket, 3-Pole 4x
LWL double 10 m, Optical Fiber, Double 10 m cropped from scope of delivery LWL double 10 m, Optical Fiber, Double 10 m 1x
Enamelled copper wire spool Wire CuL, Enamelled Copper Wire 1x
NT Ex EU power supply NT Ex EU, Power Supply Unit 1x
  OB 100 set m, User manual 1x
System case shown with the complete kit A4 case, System Case 1x

OB 100 set application and kit pictures

Application of OB 100 set
Application of OB 100 set
Scope of delivery OB 100 set
Scope of delivery OB 100 set

Connect the optical measurement path

Connect the sensor at the DUT, route the optical fiber to the receiver, and connect the receiver to the measuring instrument. Provide the specified supply separately at each end. Keep the installed fiber length within the model-specific limit. Choose the sensor voltage range and channel count before configuring the test.

The supplied 10 m fiber does not support every CAN speed configuration. The set sheet specifies a 6 m limit at 1 Mbit/s CAN.

Optical signal transmission for EMC testing

Datasheets

Compare all Langer optical signal transmission sets

KitModelSignalChannels / directionBandwidth / data rateSampling / functionSupported fiber lengthIncluded fiber
A100-1 set A100-1 set Analog 1 DC to 25 kHz 125 ksps / 12 bit 1 to 20 m 1.5 m
A100-2 set A100-2 set Analog 2 DC to 25 kHz 125 ksps / 12 bit 1 to 20 m 2 x 6 m
A200-1 set A200-1 set Analog 1 DC to 500 kHz 3 Msps / 12 bit 1 to 20 m 1.5 m
A200-2 set A200-2 set Analog 2 DC to 500 kHz 3 Msps / 12 bit 1 to 20 m 2 x 6 m
A300-1 set A300-1 set Analog 1 DC to 5 MHz 12.5 Msps / 10 bit 1 to 20 m 1.5 m
A300-2 set A300-2 set Analog 2 DC to 5 MHz 12.5 Msps / 10 bit 1 to 20 m 2 x 6 m
OSE 150-1 set OSE 150-1 set Digital 1 DC to 50 Mbps Logic transmission 1 to 20 m 1.5 m
OSE 150-2 set OSE 150-2 set Digital 2 DC to 50 Mbps Logic transmission 1 to 20 m 2 x 6 m
OSE 450 set OSE 450 set Digital 4 DC to 50 Mbps Logic transmission See receiver / sensor configuration 4 x 6 m
CAN 100 set CAN 100 set CAN Bidirectional Up to 1 Mbit/s High-speed CAN 10 m maximum; 6 m at 1 Mbit/s Double 10 m
LIN 100 set LIN 100 set LIN Bidirectional LIN bus Master / slave Up to 20 m Double 10 m
OB 100 set OB 100 set CAN / LIN Bidirectional CAN / LIN selectable 2 Opto-Boxes 20 m; 6 m at 1 Mbit/s CAN Double 10 m