Langer Z23-1 Set | 900 x 500 x 400 mm EMC Shielding Tent

900 x 500 x 400 mm | 45-50 dB from 30 MHz to 1 GHz | 12 kg | Ground plate + cover + frame

The Z23-1 Set creates a shielded space for PCB development and bench EMC measurements. Its 900 x 500 x 400 mm enclosure provides specified shielding attenuation of 45-50 dB from 30 MHz to 1 GHz. The set includes a GP 23 ground plate, BZ 23-1 conductive cover and ZG 23-1 folding frame. Magnetic sealing strips and front access make it practical to adjust the DUT between measurements.

Z23-1 set - Datasheet

SPECIFICATIONS

Z23-1 Set | 900 x 500 x 400 mm EMC Shielding Tent

The Z23-1 Set creates a shielded space for PCB development and bench EMC measurements. Its 900 x 500 x 400 mm enclosure provides specified shielding attenuation of 45-50 dB from 30 MHz to 1 GHz. The set includes a GP 23 ground plate, BZ 23-1 conductive cover and ZG 23-1 folding frame. Magnetic sealing strips and front access make it practical to adjust the DUT between measurements.

Improve the RF environment at the workbench

Benefit / taskHow to use the set
Reduce external signals Enclose the measurement arrangement when broadcast or other ambient signals make DUT emission measurements difficult.
Access the DUT quickly Open the front cover for component changes and close the magnetic seals before the next measurement.
Use a defined reference plane GP 23 supplies a conductive working surface and connections for routing power and RF measurement paths.
Store the enclosure compactly The frame folds to the rear for access and can be folded for storage when the measurement station is not in use.

The 45-50 dB figure applies over the stated 30 MHz to 1 GHz range; it is not a blanket attenuation specification at all frequencies. Instruments and DUTs shown in application photographs are illustrative and are not part of the three-component tent set.

Technical specifications

ParameterSpecification
Attenuated shielding 45 dB - 50 dB / 30 MHz - 1 GHz
Weight 12 kg
Sizes (L x W x H) (900 x 500 x 400) mm
GP 23 working surface 900 x 500 mm
GP 23 current rating 10 A
GP 23 dielectric strength 50 V
GP 23 weight 9.25 kg
Shielding cover weight 1 kg
ZG 23-1 frame weight 2 kg

Dimensions are the manufacturer's nominal L x W x H values. Component weights are listed separately from the complete-set weight.

Included components

PhotoQty.ItemFunction / key specifications
GP 23, Ground Plate 1x GP 23 Ground Plate
Current: 10 A
Dielectric strength: 50 V
Working surface (length x width): (900 x 500) mm
Weight: 9,25 kg
BZ 23-1, Shielding Material 1x BZ 23-1 Shielding Material
Attenuated shielding: 45 dB - 50 dB / 30 MHz - 1 GHz
Weight: 1 kg
Sizes (L x W x H): (900 x 500 x 400) mm
ZG 23-1, Tent Poles 1x ZG 23-1 Tent Poles
Weight: 2 kg

Z23-1 versus Z23-2

FeatureZ23-1 SetZ23-2 Set
Nominal dimensions 900 x 500 x 400 mm 900 x 500 x 650 mm
Set weight 12 kg 13 kg
Cover BZ 23-1 BZ 23-2
Frame ZG 23-1 ZG 23-1 + ZGA 23-2 adapters
Published shielding attenuation 45-50 dB / 30 MHz to 1 GHz 45-50 dB / 30 MHz to 1 GHz

Measurement setup and response charts

IllustrationWhat it shows
Shielding attenuation Manufacturer shielding attenuation curve
Opened shielding tent Front access and folding tent structure

Datasheets

DocumentOpen PDF
Z23-1 set - datasheet View PDF

Related measurement tools

PhotoProductKey specifications
ESA1 set, Emission Development System ESA1 set 11 near-field probes | 100 kHz to 1 GHz line-current measurements | 20 dB preamplifier | Shielding tent + software
HFW 21 set, RF Current Transformer 100 kHz up to 1 GHz HFW 21 set 100 kHz to 1 GHz | 10 A current rating | 50 V dielectric strength | Common-mode / differential-mode

Practical questions

QuestionAnswer
What does the tent include? One GP 23 ground plate, one BZ 23-1 shielding cover and one ZG 23-1 frame.
When should I choose Z23-2? Choose the taller version when the DUT or fixtures need more height: 650 mm instead of 400 mm, with the same nominal footprint.

Product videos

Selection guide - compare development-stage measurement sets

These sets perform different jobs. ESA1 combines several tools, while the other sets target a particular measurement task. Click a set to review its complete contents.

KitSetTypeKey range / sizeIncluded toolsChoose it for
ESA1 set, Emission Development System ESA1 set Integrated PCB emissions toolkit 11 probes: 30 MHz to 3 GHz; RF-E 02 to 1.5 GHz; HFW 21: 100 kHz to 1 GHz Tent, transformer, bypass, preamplifier, probes and software Coordinated source finding and design comparisons
HFW 21 set, RF Current Transformer 100 kHz up to 1 GHz HFW 21 set RF current transformer 100 kHz to 1 GHz; 10 A HFW 21, HFA 21, cable, accessories and case Separate common-mode and differential-mode RF currents
Z23-1 set, Shielding Tent (900 x 500 x 400) mm Z23-1 set EMC shielding tent 900 x 500 x 400 mm; 12 kg Ground plate, cover and folding frame 45-50 dB attenuation at 30 MHz to 1 GHz
Z23-2 set, Shielding Tent (900 x 500 x 650) mm Z23-2 set Taller EMC shielding tent 900 x 500 x 650 mm; 13 kg Ground plate, taller cover, frame and adapters 250 mm more height than Z23-1
NNB 21 set, Line Impedance Stabilisation Network NNB 21 set Two-channel LISN 100 kHz to 1 GHz; 10 A; 10 dB internal attenuation NNB 21, one cable, accessories and case Conducted disturbance measurements on DUT wiring
OTHER PRODUCTS IN THE SAME CATEGORY:
Loading...