900 x 500 x 400 mm | 45-50 dB from 30 MHz to 1 GHz | 12 kg | Ground plate + cover + frame
The Z23-1 Set creates a shielded space for PCB development and bench EMC measurements. Its 900 x 500 x 400 mm enclosure provides specified shielding attenuation of 45-50 dB from 30 MHz to 1 GHz. The set includes a GP 23 ground plate, BZ 23-1 conductive cover and ZG 23-1 folding frame. Magnetic sealing strips and front access make it practical to adjust the DUT between measurements.
MARKETS:
CATEGORIES:
TEST STANDARDS:
Select Options/Sizes:
The Z23-1 Set creates a shielded space for PCB development and bench EMC measurements. Its 900 x 500 x 400 mm enclosure provides specified shielding attenuation of 45-50 dB from 30 MHz to 1 GHz. The set includes a GP 23 ground plate, BZ 23-1 conductive cover and ZG 23-1 folding frame. Magnetic sealing strips and front access make it practical to adjust the DUT between measurements.
| Benefit / task | How to use the set |
|---|---|
| Reduce external signals | Enclose the measurement arrangement when broadcast or other ambient signals make DUT emission measurements difficult. |
| Access the DUT quickly | Open the front cover for component changes and close the magnetic seals before the next measurement. |
| Use a defined reference plane | GP 23 supplies a conductive working surface and connections for routing power and RF measurement paths. |
| Store the enclosure compactly | The frame folds to the rear for access and can be folded for storage when the measurement station is not in use. |
The 45-50 dB figure applies over the stated 30 MHz to 1 GHz range; it is not a blanket attenuation specification at all frequencies. Instruments and DUTs shown in application photographs are illustrative and are not part of the three-component tent set.
| Parameter | Specification |
|---|---|
| Attenuated shielding | 45 dB - 50 dB / 30 MHz - 1 GHz |
| Weight | 12 kg |
| Sizes (L x W x H) | (900 x 500 x 400) mm |
| GP 23 working surface | 900 x 500 mm |
| GP 23 current rating | 10 A |
| GP 23 dielectric strength | 50 V |
| GP 23 weight | 9.25 kg |
| Shielding cover weight | 1 kg |
| ZG 23-1 frame weight | 2 kg |
Dimensions are the manufacturer's nominal L x W x H values. Component weights are listed separately from the complete-set weight.
| Feature | Z23-1 Set | Z23-2 Set |
|---|---|---|
| Nominal dimensions | 900 x 500 x 400 mm | 900 x 500 x 650 mm |
| Set weight | 12 kg | 13 kg |
| Cover | BZ 23-1 | BZ 23-2 |
| Frame | ZG 23-1 | ZG 23-1 + ZGA 23-2 adapters |
| Published shielding attenuation | 45-50 dB / 30 MHz to 1 GHz | 45-50 dB / 30 MHz to 1 GHz |
| Illustration | What it shows |
|---|---|
![]() |
Manufacturer shielding attenuation curve |
![]() |
Front access and folding tent structure |
| Document | Open PDF |
|---|---|
| Z23-1 set - datasheet | View PDF |
| Photo | Product | Key specifications |
|---|---|---|
![]() |
ESA1 set | 11 near-field probes | 100 kHz to 1 GHz line-current measurements | 20 dB preamplifier | Shielding tent + software |
![]() |
HFW 21 set | 100 kHz to 1 GHz | 10 A current rating | 50 V dielectric strength | Common-mode / differential-mode |
| Question | Answer |
|---|---|
| What does the tent include? | One GP 23 ground plate, one BZ 23-1 shielding cover and one ZG 23-1 frame. |
| When should I choose Z23-2? | Choose the taller version when the DUT or fixtures need more height: 650 mm instead of 400 mm, with the same nominal footprint. |
These sets perform different jobs. ESA1 combines several tools, while the other sets target a particular measurement task. Click a set to review its complete contents.
| Kit | Set | Type | Key range / size | Included tools | Choose it for |
|---|---|---|---|---|---|
![]() |
ESA1 set | Integrated PCB emissions toolkit | 11 probes: 30 MHz to 3 GHz; RF-E 02 to 1.5 GHz; HFW 21: 100 kHz to 1 GHz | Tent, transformer, bypass, preamplifier, probes and software | Coordinated source finding and design comparisons |
![]() |
HFW 21 set | RF current transformer | 100 kHz to 1 GHz; 10 A | HFW 21, HFA 21, cable, accessories and case | Separate common-mode and differential-mode RF currents |
![]() |
Z23-1 set | EMC shielding tent | 900 x 500 x 400 mm; 12 kg | Ground plate, cover and folding frame | 45-50 dB attenuation at 30 MHz to 1 GHz |
![]() |
Z23-2 set | Taller EMC shielding tent | 900 x 500 x 650 mm; 13 kg | Ground plate, taller cover, frame and adapters | 250 mm more height than Z23-1 |
![]() |
NNB 21 set | Two-channel LISN | 100 kHz to 1 GHz; 10 A; 10 dB internal attenuation | NNB 21, one cable, accessories and case | Conducted disturbance measurements on DUT wiring |