EMSCOPE-RX4, 9kHz - 110MHz, 4 channel Receiver for 3 phase

Measure three-phase conducted emissions and investigate common/differential-mode noise with the four-channel EMSCOPE platform. Choose RX4 for external-LISN testing or RX4LZ2 for an added built-in 16 A single-phase LISN. Three-phase testing uses a suitable external network. Click meter and frequency upgrades are available.

Select Options/Sizes:

Data Sheet

Article on Filter Design

EMSCOPE Advantages

SPECIFICATIONS

EMZER | CONDUCTED EMISSIONS & EMC DIAGNOSTICS

EMSCOPE-RX4 / RX4LZ2 Four-Channel EMI Receivers

Four receiver channels. Clear single-phase and three-phase choices.

Choose RX4 or RX4LZ2

EMSCOPE-RX4 Four receiver channels and four transient limiters. No internal LISN. Select an external network for the EUT.
EMSCOPE-RX4LZ2 Four channels plus an internal dual-port 16 A single-phase LISN. The built-in network adds single-phase bench capability; it does not supply a three-phase EUT.
EMZER EMSCOPE-RX4 with four RF inputs and no internal LISN

RX4: N, L3, L2 and L1 RF inputs for an external network.

 
EMZER EMSCOPE-RX4LZ2 four-channel receiver with single-phase LISN

RX4LZ2 adds a single-phase LISN and EUT outlet. Use an external three-phase LISN for three-phase power-line testing.

Find the source of three-phase conducted EMI

Evaluate physical line signals and use common-mode plus three differential-mode results to investigate filter performance. Separate noise mechanisms before selecting filter components. Detector display and channel combinations depend on operating mode.

Frequency configuration: EMSCOPE-RX4 and EMSCOPE-RX4LZ2 start at 150 kHz as standard. Add UPGR-09 to extend coverage down to 9 kHz. The separate UPGR-110 option extends the upper limit from 30 MHz to 110 MHz.

Measurement setup

1. Connect the EUT Use the internal single-phase LISN where fitted and suitable, or a correctly rated external network.
2. Connect the receiver Connect measurement outputs to the appropriate RF inputs using suitable coaxial cables.
3. Select the measurement Choose EMI or modal mode, span, detectors, bandwidth, dwell time and the applicable limit line.
4. Compare and document Review traces, identify dominant noise modes and export results. Add the click meter license for discontinuous disturbance testing.

EMI and modal measurement views

EMZER modal conducted-emissions measurement display

Manufacturer example display. Compare noise modes to inform filter selection; illustrated traces are not performance guarantees.

Technical specifications

Receiver channels / transient limiters 4 / 4; both RX4 and RX4LZ2
Base frequency range 150 kHz–30 MHz standard
Low-frequency extension Down to 9 kHz with optional UPGR-09
Upper-frequency upgrade 110 MHz available
Receiver standard CISPR 16-1-1, as specified by EMZER
EMI detectors Peak, quasi-peak and average
Measurement modes Conducted EMI and modal analysis (common mode and differential mode)
Full-spectrum measurement time Equal to selected dwell time; configurable from 1 s to 15 s
CISPR resolution bandwidths 200 Hz, 9 kHz and 120 kHz
MIL resolution bandwidths 1 kHz and 10 kHz
Integrated circuitry Preamplifiers and transient/pulse limiters
Control and communication Embedded web application; optical fiber with fiber/Ethernet converter
Software functions EMI/modal measurements, waterfall/spectrogram, result comparison, preset settings and report export
Export formats CSV, PDF and image, as supported by the measurement mode
Optional functions Click meter; oscilloscope/time-domain analysis; model-specific frequency upgrades
Dimensions (W × H × D) 252 × 195 × 438 mm
Weight 5.5 kg for RX4 per webpage; RX4LZ2 weight to be confirmed

Integrated LISN specifications — RX4LZ2 only

LISN type / standard Dual-port, single-phase V-network; CISPR 16-1-2
Equivalent circuit / pre-filter choke 50 Ω || (50 μH + 5 Ω) / 250 μH
Maximum continuous current Up to 16 A at 230 VAC; socket dependent
Maximum operating voltage Up to 300 VAC / 325 VDC; socket dependent
EUT supply frequency DC to 60 Hz
Artificial hand 510 Ω + 220 pF; 4 mm banana/socket connection
Mains input IEC C20
EUT socket Schuko Type F shown in manufacturer data. EU, USA, UK and CN-AUS selections are listed; specify the North American outlet and verify its ratings.
These limits apply to the fitted single-phase LISN and its socket. Confirm the outlet, EUT voltage and continuous current for the ordered configuration.

Watch emissions change over time

EMSCOPE waterfall spectrogram of conducted emissions over time

The included waterfall/spectrogram helps reveal emissions that change during an operating cycle.

Options and configuration

OptionAvailabilityPurpose
UPGR-110 Optional Extends upper frequency limit from 30 MHz to 110 MHz.
UPGR-09 Optional on RX4/RX4LZ2 Extends the lower frequency limit from 150 kHz down to 9 kHz.
Click meter license Optional on all models CISPR 14-1 click meter for discontinuous disturbance testing.
UPGR-OSC Optional Time-domain / oscilloscope mode.
Fiber/USB converter Optional Optical-fiber connection to a USB-equipped host.
EUT socket selection Specify when ordering Applies to the internal single-phase LISN; verify outlet current/voltage limits.

Components and supporting equipment

Included with selected model Four-channel receiver; four transient limiters; embedded EMI/modal software; optical-fiber communication and fiber/Ethernet converter. RX4LZ2 also includes the dual-port 16 A single-phase LISN.
Required for testing Browser-equipped control device; suitable EUT supply, grounding, measurement cables and test network. Confirm supplied cable lengths and socket configuration with the quotation.
External LISN Required for RX2/RX4 power-line testing and RX4LZ2 three-phase testing. Select voltage, current and impedance for the EUT and test method.
Separately licensed options Click meter and oscilloscope functions; frequency upgrades as specified for the configuration.

Add a CISPR 14-1 click meter

An optional click meter license adds discontinuous disturbance testing. Evaluate line and neutral, view four measurement frequencies, review click statistics and generate PDF reports. Available for all four EMSCOPE models.

Explore the EMSCOPE click meter option

Practical questions

Does RX4LZ2 include a three-phase LISN?

No. Its internal LISN is single-phase. Three-phase testing requires a separately specified external network with suitable current, voltage and impedance ratings.

Is the click meter included?

No. It is an optional license for discontinuous disturbance testing. Normal EMI and modal software is included.

Do I need to install measurement software?

The application is embedded in the instrument and accessed in a browser. A browser-equipped device and suitable optical/network connection are still required.

Is 110 MHz standard?

The model table lists 30 MHz base coverage and UPGR-110 as an available upgrade. Specify the required coverage in the quotation.

Downloads and technical resources

Existing Absolute EMC datasheet
Power-line filter design article
EMSCOPE advantages
Current EMZER family technical sheet

Compare all four EMSCOPE models

Choose channel count and LISN arrangement first. All four models support the optional CISPR 14-1 click meter.

ModelReceiver channelsLISN configurationBase frequency rangeBest fit
EMSCOPEEMZER EMSCOPE 2 Built-in single-phase, 16 A 9 kHz–30 MHz Integrated single-phase bench testing.
EMSCOPE-RX2EMZER EMSCOPE-RX2 2 External LISN required 9 kHz–30 MHz Application-specific external networks.
EMSCOPE-RX4EMZER EMSCOPE-RX4 4 External LISN required 150 kHz–30 MHz* Three-phase EMI and modal troubleshooting.
EMSCOPE-RX4LZ2EMZER EMSCOPE-RX4LZ2 4 Built-in single-phase, 16 A; external network for three-phase 150 kHz–30 MHz* Single-phase bench work plus external three-phase setups.

Shared capabilities: peak, quasi-peak and average EMI detectors; common/differential-mode analysis; embedded browser software; fiber/Ethernet converter; available 110 MHz upgrade; optional oscilloscope and click meter licenses. Transient limiters: two on EMSCOPE/RX2 and four on RX4/RX4LZ2.

*RX4 frequency selection: EMSCOPE-RX4 and EMSCOPE-RX4LZ2 start at 150 kHz as standard. Add UPGR-09 to extend coverage down to 9 kHz. The separate UPGR-110 option extends the upper limit from 30 MHz to 110 MHz.