100 kHz to 1 GHz | 2 measurement channels | 10 A | 10 dB internal attenuation | Less than 20 milliohm
The Langer NNB 21 Set is a two-channel line impedance stabilization network for conducted EMI development measurements, including automotive wiring systems. It covers 100 kHz to 1 GHz, is rated for 10 A, has 50 V dielectric strength and less than 20 milliohm DC resistance. Measure two circuits separately or simultaneously. A 1 m SMB-BNC cable, connection accessories, manual and case are included.
MARKETS:
CATEGORIES:
TEST STANDARDS:
Select Options/Sizes:
The Langer NNB 21 Set is a two-channel line impedance stabilization network for conducted EMI development measurements, including automotive wiring systems. It covers 100 kHz to 1 GHz, is rated for 10 A, has 50 V dielectric strength and less than 20 milliohm DC resistance. Measure two circuits separately or simultaneously. A 1 m SMB-BNC cable, connection accessories, manual and case are included.
| Benefit / task | How to use the set |
|---|---|
| Measure supply-line EMI | Connect the DUT wiring through the network and observe the RF measurement output with a suitable spectrum analyzer or receiver. |
| Use two measurement channels | Investigate either circuit individually or compare both circuits using the corresponding measurement arrangement. |
| Account for attenuation | Include the specified 10 dB internal attenuation when interpreting levels; also account for the cable and instrument settings. |
| Preserve repeatability | Keep wiring, grounding, operating mode and the reference plane arrangement consistent when checking design modifications. |
NNB 21 is intended for development-stage conducted-emission measurements. CISPR 25 and ISO 7637 references describe intended applications; verify the required impedance characteristic, setup and instrument against the exact test method. The set includes one measurement cable although the network has two channels.
| Parameter | Specification |
|---|---|
| Frequency range | 100 kHz - 1 GHz |
| DC resistance | < 20 mohm |
| Internal attenuation | 10 dB |
| Measuring channels | 2 |
| Current | 10 A |
| Dielectric strength | 50 V |
| Weight | 400 g |
Dielectric strength is reproduced as specified by the manufacturer; it is not relabeled here as a continuous operating-voltage rating.
| Photo | Qty. | Item | Function / key specifications |
|---|---|---|---|
![]() |
1x | NNB 21 | Line Impedance Stabilisation Network Frequency range: 100 kHz - 1 GHz DC resistance: < 20 mohm Internal attenuation: 10 dB Measuring channels: 2 |
![]() |
1x | SMB-BNC 1 m | SMB-BNC Measurement Cable 1 m SMB-to-BNC measurement cable; 25 g. |
![]() |
1x | NNB 21 acc | Accessories Connection accessories / two-pole clamp terminals. |
| 1x | NNB 21 case | System Case Protective system case. |
|
| 1x | NNB 21 m | NNB 21 Set User Manual NNB 21 operating instructions. |
| Illustration | What it shows |
|---|---|
![]() |
NNB 21 application arrangement |
![]() |
Two-channel measurement arrangement |
![]() |
NNB 21 Frequency response |
![]() |
NNB 21 Frequency response |
![]() |
NNB 21 Impedance |
| Document | Open PDF |
|---|---|
| NNB 21 set - datasheet | View PDF |
| Photo | Product | Key specifications |
|---|---|---|
![]() |
ESA1 set | 11 near-field probes | 100 kHz to 1 GHz line-current measurements | 20 dB preamplifier | Shielding tent + software |
![]() |
HFW 21 set | 100 kHz to 1 GHz | 10 A current rating | 50 V dielectric strength | Common-mode / differential-mode |
| Question | Answer |
|---|---|
| How many channels and cables are included? | The network has two measurement channels; the set lists one 1 m SMB-BNC measurement cable. |
| Is 50 V the stated operating voltage? | The literature labels 50 V as dielectric strength. Confirm the intended DUT supply and test arrangement; do not substitute this value for an unstated operating-voltage specification. |
| What does the 10 dB specification mean? | It is the network's internal attenuation, to be accounted for when interpreting the RF measurement. |
These sets perform different jobs. ESA1 combines several tools, while the other sets target a particular measurement task. Click a set to review its complete contents.
| Kit | Set | Type | Key range / size | Included tools | Choose it for |
|---|---|---|---|---|---|
![]() |
ESA1 set | Integrated PCB emissions toolkit | 11 probes: 30 MHz to 3 GHz; RF-E 02 to 1.5 GHz; HFW 21: 100 kHz to 1 GHz | Tent, transformer, bypass, preamplifier, probes and software | Coordinated source finding and design comparisons |
![]() |
HFW 21 set | RF current transformer | 100 kHz to 1 GHz; 10 A | HFW 21, HFA 21, cable, accessories and case | Separate common-mode and differential-mode RF currents |
![]() |
Z23-1 set | EMC shielding tent | 900 x 500 x 400 mm; 12 kg | Ground plate, cover and folding frame | 45-50 dB attenuation at 30 MHz to 1 GHz |
![]() |
Z23-2 set | Taller EMC shielding tent | 900 x 500 x 650 mm; 13 kg | Ground plate, taller cover, frame and adapters | 250 mm more height than Z23-1 |
![]() |
NNB 21 set | Two-channel LISN | 100 kHz to 1 GHz; 10 A; 10 dB internal attenuation | NNB 21, one cable, accessories and case | Conducted disturbance measurements on DUT wiring |