Langer NNB 21 Set | Two-Channel 100 kHz to 1 GHz LISN

100 kHz to 1 GHz | 2 measurement channels | 10 A | 10 dB internal attenuation | Less than 20 milliohm

The Langer NNB 21 Set is a two-channel line impedance stabilization network for conducted EMI development measurements, including automotive wiring systems. It covers 100 kHz to 1 GHz, is rated for 10 A, has 50 V dielectric strength and less than 20 milliohm DC resistance. Measure two circuits separately or simultaneously. A 1 m SMB-BNC cable, connection accessories, manual and case are included.

NNB 21 set - Datasheet

SPECIFICATIONS

NNB 21 Set | Two-Channel 100 kHz to 1 GHz LISN

The Langer NNB 21 Set is a two-channel line impedance stabilization network for conducted EMI development measurements, including automotive wiring systems. It covers 100 kHz to 1 GHz, is rated for 10 A, has 50 V dielectric strength and less than 20 milliohm DC resistance. Measure two circuits separately or simultaneously. A 1 m SMB-BNC cable, connection accessories, manual and case are included.

Compare conducted disturbance on two DUT circuits

Benefit / taskHow to use the set
Measure supply-line EMI Connect the DUT wiring through the network and observe the RF measurement output with a suitable spectrum analyzer or receiver.
Use two measurement channels Investigate either circuit individually or compare both circuits using the corresponding measurement arrangement.
Account for attenuation Include the specified 10 dB internal attenuation when interpreting levels; also account for the cable and instrument settings.
Preserve repeatability Keep wiring, grounding, operating mode and the reference plane arrangement consistent when checking design modifications.

NNB 21 is intended for development-stage conducted-emission measurements. CISPR 25 and ISO 7637 references describe intended applications; verify the required impedance characteristic, setup and instrument against the exact test method. The set includes one measurement cable although the network has two channels.

Technical specifications

ParameterSpecification
Frequency range 100 kHz - 1 GHz
DC resistance < 20 mohm
Internal attenuation 10 dB
Measuring channels 2
Current 10 A
Dielectric strength 50 V
Weight 400 g

Dielectric strength is reproduced as specified by the manufacturer; it is not relabeled here as a continuous operating-voltage rating.

Included components

PhotoQty.ItemFunction / key specifications
NNB 21, Line Impedance Stabilisation Network 1x NNB 21 Line Impedance Stabilisation Network
Frequency range: 100 kHz - 1 GHz
DC resistance: < 20 mohm
Internal attenuation: 10 dB
Measuring channels: 2
SMB-BNC 1 m, SMB-BNC Measurement Cable 1x SMB-BNC 1 m SMB-BNC Measurement Cable
1 m SMB-to-BNC measurement cable; 25 g.
NNB 21 clamp terminals 1x NNB 21 acc Accessories
Connection accessories / two-pole clamp terminals.
  1x NNB 21 case System Case
Protective system case.
  1x NNB 21 m NNB 21 Set User Manual
NNB 21 operating instructions.

Measurement setup and response charts

IllustrationWhat it shows
Application with NNB 21 NNB 21 application arrangement
Measurement with NNB21 Two-channel measurement arrangement
NNB 21 Frequency response NNB 21 Frequency response
NNB 21 Frequency response NNB 21 Frequency response
NNB 21 Impedance NNB 21 Impedance

Datasheets

DocumentOpen PDF
NNB 21 set - datasheet View PDF

Related measurement tools

PhotoProductKey specifications
ESA1 set, Emission Development System ESA1 set 11 near-field probes | 100 kHz to 1 GHz line-current measurements | 20 dB preamplifier | Shielding tent + software
HFW 21 set, RF Current Transformer 100 kHz up to 1 GHz HFW 21 set 100 kHz to 1 GHz | 10 A current rating | 50 V dielectric strength | Common-mode / differential-mode

Practical questions

QuestionAnswer
How many channels and cables are included? The network has two measurement channels; the set lists one 1 m SMB-BNC measurement cable.
Is 50 V the stated operating voltage? The literature labels 50 V as dielectric strength. Confirm the intended DUT supply and test arrangement; do not substitute this value for an unstated operating-voltage specification.
What does the 10 dB specification mean? It is the network's internal attenuation, to be accounted for when interpreting the RF measurement.

Selection guide - compare development-stage measurement sets

These sets perform different jobs. ESA1 combines several tools, while the other sets target a particular measurement task. Click a set to review its complete contents.

KitSetTypeKey range / sizeIncluded toolsChoose it for
ESA1 set, Emission Development System ESA1 set Integrated PCB emissions toolkit 11 probes: 30 MHz to 3 GHz; RF-E 02 to 1.5 GHz; HFW 21: 100 kHz to 1 GHz Tent, transformer, bypass, preamplifier, probes and software Coordinated source finding and design comparisons
HFW 21 set, RF Current Transformer 100 kHz up to 1 GHz HFW 21 set RF current transformer 100 kHz to 1 GHz; 10 A HFW 21, HFA 21, cable, accessories and case Separate common-mode and differential-mode RF currents
Z23-1 set, Shielding Tent (900 x 500 x 400) mm Z23-1 set EMC shielding tent 900 x 500 x 400 mm; 12 kg Ground plate, cover and folding frame 45-50 dB attenuation at 30 MHz to 1 GHz
Z23-2 set, Shielding Tent (900 x 500 x 650) mm Z23-2 set Taller EMC shielding tent 900 x 500 x 650 mm; 13 kg Ground plate, taller cover, frame and adapters 250 mm more height than Z23-1
NNB 21 set, Line Impedance Stabilisation Network NNB 21 set Two-channel LISN 100 kHz to 1 GHz; 10 A; 10 dB internal attenuation NNB 21, one cable, accessories and case Conducted disturbance measurements on DUT wiring
OTHER PRODUCTS IN THE SAME CATEGORY: