




100 kHz to 1 GHz | 10 A current rating | 50 V dielectric strength | Common-mode / differential-mode
The HFW 21 Set measures RF currents in DUT wiring and helps separate common-mode and differential-mode noise. The transformer is rated for 10 A with 50 V dielectric strength. A metallic reference ground plane is needed for reproducible measurements; the set includes the HFA 21 RF bypass, a 1 m SMB-BNC measurement cable, accessories, manual and case.
MARKETS:
CATEGORIES:
TEST STANDARDS:
Select Options/Sizes:
The HFW 21 Set measures RF currents in DUT wiring and helps separate common-mode and differential-mode noise. The transformer is rated for 10 A with 50 V dielectric strength. A metallic reference ground plane is needed for reproducible measurements; the set includes the HFA 21 RF bypass, a 1 m SMB-BNC measurement cable, accessories, manual and case.
| Benefit / task | How to use the set |
|---|---|
| Identify common-mode noise | Compare current components on the DUT lines to determine whether a shared return path or cable radiation mechanism needs attention. |
| Investigate differential-mode noise | Use the differential measurement arrangement to study noise within the supply loop and evaluate filtering choices. |
| Evaluate bypass components | The HFA 21 provides capacitance selections from 10 pF to 100 nF for controlled suppression experiments. |
| Keep the reference consistent | Mount the measurement arrangement on a metallic ground plane and maintain DUT wiring, operating state and instrument settings between comparisons. |
HFW 21 is an RF current transformer, not a LISN. Select NNB 21 when an impedance stabilization network is needed. A suitable RF measurement instrument and metallic reference ground plane are required separately unless already available.
| Parameter | Specification |
|---|---|
| Frequency range | 100 kHz - 1 GHz |
| Weight | 400 g |
| HFW 21 continuous current rating | 10 A |
| HFW 21 dielectric strength | 50 V |
| HFW 21 dimensions (L x W x H) | 115 x 65 x 28 mm (current component listing) |
| HFA 21 capacitance selections | 10 pF; 100 pF; 1 nF; 10 nF; 100 nF |
| HFA 21 dielectric strength | 50 V |
| HFA 21 dimensions (L x W x H) | 70 x 50 x 18 mm |
Dielectric strength is reproduced as specified by the manufacturer; it is not relabeled here as a continuous operating-voltage rating.
| Photo | Qty. | Item | Function / key specifications |
|---|---|---|---|
![]() |
1x | HFW 21 | RF Current Transformer Frequency range: 100 kHz - 1 GHz Current: 10 A Dielectric strength: 50 V Sizes (L x W x H): (115 x 65 x 28) mm |
![]() |
1x | HFA 21 | RF Bypass Capacitances: 10 pF ... 100 nF Dielectric strength: 50 V Sizes (L x W x H): (70 x 50 x 18) mm |
![]() |
1x | SMB-BNC 1 m | SMB-BNC Measurement Cable 1 m SMB-to-BNC measurement cable; 25 g. |
![]() |
1x | HFW 21 acc | Accessories Connection leads and adapters for the HFW 21 measurement arrangement. |
| 1x | ESA1 m | User Manual Operating instructions for the measurement system. |
|
| 1x | HFW 21 case | System Case Protective system case. |
| Illustration | What it shows |
|---|---|
![]() |
HFW 21 application arrangement |
![]() |
HFW 21 frequency response |
![]() |
HFW 21 frequency response detail |
| Document | Open PDF |
|---|---|
| HFW 21 set - datasheet | View PDF |
| Photo | Product | Key specifications |
|---|---|---|
![]() |
ESA1 set | 11 near-field probes | 100 kHz to 1 GHz line-current measurements | 20 dB preamplifier | Shielding tent + software |
![]() |
NNB 21 set | 100 kHz to 1 GHz | 2 measurement channels | 10 A | 10 dB internal attenuation | Less than 20 milliohm |
| Question | Answer |
|---|---|
| Is HFW 21 a clamp-on probe? | It is a line-connected RF current-transformer arrangement with defined DUT connections. Follow its setup instructions rather than treating it as a general clamp-on probe. |
| What else is needed? | A metallic reference ground plane and suitable RF measurement instrument are needed. The HFA 21 bypass and one 1 m SMB-BNC cable are included. |
These sets perform different jobs. ESA1 combines several tools, while the other sets target a particular measurement task. Click a set to review its complete contents.
| Kit | Set | Type | Key range / size | Included tools | Choose it for |
|---|---|---|---|---|---|
![]() |
ESA1 set | Integrated PCB emissions toolkit | 11 probes: 30 MHz to 3 GHz; RF-E 02 to 1.5 GHz; HFW 21: 100 kHz to 1 GHz | Tent, transformer, bypass, preamplifier, probes and software | Coordinated source finding and design comparisons |
![]() |
HFW 21 set | RF current transformer | 100 kHz to 1 GHz; 10 A | HFW 21, HFA 21, cable, accessories and case | Separate common-mode and differential-mode RF currents |
![]() |
Z23-1 set | EMC shielding tent | 900 x 500 x 400 mm; 12 kg | Ground plate, cover and folding frame | 45-50 dB attenuation at 30 MHz to 1 GHz |
![]() |
Z23-2 set | Taller EMC shielding tent | 900 x 500 x 650 mm; 13 kg | Ground plate, taller cover, frame and adapters | 250 mm more height than Z23-1 |
![]() |
NNB 21 set | Two-channel LISN | 100 kHz to 1 GHz; 10 A; 10 dB internal attenuation | NNB 21, one cable, accessories and case | Conducted disturbance measurements on DUT wiring |