Langer HFW 21 Set | 100 kHz to 1 GHz RF Current Transformer

100 kHz to 1 GHz | 10 A current rating | 50 V dielectric strength | Common-mode / differential-mode

The HFW 21 Set measures RF currents in DUT wiring and helps separate common-mode and differential-mode noise. The transformer is rated for 10 A with 50 V dielectric strength. A metallic reference ground plane is needed for reproducible measurements; the set includes the HFA 21 RF bypass, a 1 m SMB-BNC measurement cable, accessories, manual and case.

HFW 21 set - Datasheet

SPECIFICATIONS

HFW 21 Set | 100 kHz to 1 GHz RF Current Transformer

The HFW 21 Set measures RF currents in DUT wiring and helps separate common-mode and differential-mode noise. The transformer is rated for 10 A with 50 V dielectric strength. A metallic reference ground plane is needed for reproducible measurements; the set includes the HFA 21 RF bypass, a 1 m SMB-BNC measurement cable, accessories, manual and case.

Separate RF current paths during PCB development

Benefit / taskHow to use the set
Identify common-mode noise Compare current components on the DUT lines to determine whether a shared return path or cable radiation mechanism needs attention.
Investigate differential-mode noise Use the differential measurement arrangement to study noise within the supply loop and evaluate filtering choices.
Evaluate bypass components The HFA 21 provides capacitance selections from 10 pF to 100 nF for controlled suppression experiments.
Keep the reference consistent Mount the measurement arrangement on a metallic ground plane and maintain DUT wiring, operating state and instrument settings between comparisons.

HFW 21 is an RF current transformer, not a LISN. Select NNB 21 when an impedance stabilization network is needed. A suitable RF measurement instrument and metallic reference ground plane are required separately unless already available.

Technical specifications

ParameterSpecification
Frequency range 100 kHz - 1 GHz
Weight 400 g
HFW 21 continuous current rating 10 A
HFW 21 dielectric strength 50 V
HFW 21 dimensions (L x W x H) 115 x 65 x 28 mm (current component listing)
HFA 21 capacitance selections 10 pF; 100 pF; 1 nF; 10 nF; 100 nF
HFA 21 dielectric strength 50 V
HFA 21 dimensions (L x W x H) 70 x 50 x 18 mm

Dielectric strength is reproduced as specified by the manufacturer; it is not relabeled here as a continuous operating-voltage rating.

Included components

PhotoQty.ItemFunction / key specifications
HFW 21, RF Current Transformer 1x HFW 21 RF Current Transformer
Frequency range: 100 kHz - 1 GHz
Current: 10 A
Dielectric strength: 50 V
Sizes (L x W x H): (115 x 65 x 28) mm
HFA 21, RF Bypass 1x HFA 21 RF Bypass
Capacitances: 10 pF ... 100 nF
Dielectric strength: 50 V
Sizes (L x W x H): (70 x 50 x 18) mm
SMB-BNC 1 m, SMB-BNC Measurement Cable 1x SMB-BNC 1 m SMB-BNC Measurement Cable
1 m SMB-to-BNC measurement cable; 25 g.
HFW 21 accessory leads 1x HFW 21 acc Accessories
Connection leads and adapters for the HFW 21 measurement arrangement.
  1x ESA1 m User Manual
Operating instructions for the measurement system.
  1x HFW 21 case System Case
Protective system case.

Measurement setup and response charts

IllustrationWhat it shows
Application HFW 21 HFW 21 application arrangement
HFW 21 frequency response HFW 21 frequency response
HFW 21 frequency response detail HFW 21 frequency response detail

Datasheets

DocumentOpen PDF
HFW 21 set - datasheet View PDF

Related measurement tools

PhotoProductKey specifications
ESA1 set, Emission Development System ESA1 set 11 near-field probes | 100 kHz to 1 GHz line-current measurements | 20 dB preamplifier | Shielding tent + software
NNB 21 set, Line Impedance Stabilisation Network NNB 21 set 100 kHz to 1 GHz | 2 measurement channels | 10 A | 10 dB internal attenuation | Less than 20 milliohm

Practical questions

QuestionAnswer
Is HFW 21 a clamp-on probe? It is a line-connected RF current-transformer arrangement with defined DUT connections. Follow its setup instructions rather than treating it as a general clamp-on probe.
What else is needed? A metallic reference ground plane and suitable RF measurement instrument are needed. The HFA 21 bypass and one 1 m SMB-BNC cable are included.

Selection guide - compare development-stage measurement sets

These sets perform different jobs. ESA1 combines several tools, while the other sets target a particular measurement task. Click a set to review its complete contents.

KitSetTypeKey range / sizeIncluded toolsChoose it for
ESA1 set, Emission Development System ESA1 set Integrated PCB emissions toolkit 11 probes: 30 MHz to 3 GHz; RF-E 02 to 1.5 GHz; HFW 21: 100 kHz to 1 GHz Tent, transformer, bypass, preamplifier, probes and software Coordinated source finding and design comparisons
HFW 21 set, RF Current Transformer 100 kHz up to 1 GHz HFW 21 set RF current transformer 100 kHz to 1 GHz; 10 A HFW 21, HFA 21, cable, accessories and case Separate common-mode and differential-mode RF currents
Z23-1 set, Shielding Tent (900 x 500 x 400) mm Z23-1 set EMC shielding tent 900 x 500 x 400 mm; 12 kg Ground plate, cover and folding frame 45-50 dB attenuation at 30 MHz to 1 GHz
Z23-2 set, Shielding Tent (900 x 500 x 650) mm Z23-2 set Taller EMC shielding tent 900 x 500 x 650 mm; 13 kg Ground plate, taller cover, frame and adapters 250 mm more height than Z23-1
NNB 21 set, Line Impedance Stabilisation Network NNB 21 set Two-channel LISN 100 kHz to 1 GHz; 10 A; 10 dB internal attenuation NNB 21, one cable, accessories and case Conducted disturbance measurements on DUT wiring
OTHER PRODUCTS IN THE SAME CATEGORY:
Loading...