Active + passive H-field probes | 3 MSA 02 heads | Optical signal transfer | MSA 02: 1 AAA battery
S2 adds active and passive magnetic field probes for investigating fast transient fields caused by burst and ESD. The MSA 02 active probe accepts three heads; MS 101 and MS 102U add sensing geometries. Langer recommends S2 with E1 and E2. The supplied S2 sheet describes operation with the SGZ 21 receiver from E1; confirm the receiver arrangement when configuring S2 with E2. S2 is a sensing kit, not a disturbance generator.
MARKETS:
CATEGORIES:
TEST STANDARDS:
Select Options/Sizes:
S2 adds active and passive magnetic field probes for investigating fast transient fields caused by burst and ESD. The MSA 02 active probe accepts three heads; MS 101 and MS 102U add sensing geometries. Langer recommends S2 with E1 and E2. The supplied S2 sheet describes operation with the SGZ 21 receiver from E1; confirm the receiver arrangement when configuring S2 with E2. S2 is a sensing kit, not a disturbance generator.
| Feature | Engineering benefit / use |
|---|---|
| Active sensing | MSA 02 uses one AAA battery and accepts the included black 05K, white 05R and orange 05U heads. |
| Passive sensing | MS 101 and MS 102U extend the choice of probe geometry for following fast transient magnetic fields. |
| Receiver configuration | The supplied S2 sheet describes the SGZ 21 receiver from E1. The current E2 page also recommends S2; confirm the intended receiver connections when specifying an E2 system. |
| Parameter | Specification |
|---|---|
| Sensor types | MSA 02 active; MS 101 and MS 102U passive magnetic probes |
| MSA 02 heads | 05K black; 05R white; 05U orange |
| Receiver arrangement | SGZ 21 documented in supplied S2 sheet; S2 recommended for E2 on current manufacturer page - confirm configuration |
| MSA 02 supply | One AAA battery |
| Component | Parameter | Specification |
|---|---|---|
| MSA 02 | Resolution | < 1 mm |
| MS 101 | Weight | 10 g |
| Image | What it shows |
|---|---|
![]() |
Application with Probe MSA 02-05U |
![]() |
Application with probe MS 102U |
![]() |
Sope of delivery Set S2 |
SGZ 21 receiver documented; confirm E2 receiver arrangement. SGZ 21 is not included in S2. Select a suitable observation setup for the transient event.
| Photo | Product | Specifications / purpose | Ordering |
|---|---|---|---|
![]() |
SGZ 21 | Approx. 0-1500 V; 2 ns rise / 10 ns tail; 12 V / 200 mA supply. SGZ 21 is also included in the complete E1 set. | Recommended supporting item; not included unless stated |
| Battery AAA | 1.5 V AAA battery. Power source for the relevant mini generator or MSA 02; confirm quantity with the quotation. | Recommended supporting item; not included unless stated |
| Document | |
|---|---|
| S2 set - Datasheet | View PDF |
| Question | Answer |
|---|---|
| What is this product best suited to? | Observe disturbance paths and correlate magnetic transients with a failure. |
| What supporting equipment is needed? | SGZ 21 receiver documented; confirm E2 receiver arrangement. SGZ 21 is not included in S2. Select a suitable observation setup for the transient event. |
| Does this establish compliance with IEC 61000-4-4 or IEC 61000-4-2? | These are development and diagnostic tools. Relating a local disturbance to an EFT/burst or ESD failure helps troubleshooting; formal compliance requires the applicable standardized generator, coupling method, test setup and procedure. |
Compare generation, coupling and detection tools. The kit pictures identify the complete sets. Product links below use the planned Absolute EMC product pages.
| Kit | Product / function | Key distinction | Required pulse source / power |
|---|---|---|---|
![]() |
E1 set Integrated generation and local E/H-field troubleshooting |
Approx. 0-1500 V pulses | 2 ns rise / 10 ns tail | 4 H-field + 5 E-field sources | 10 Mbps optical sensor | SGZ 21 included; 12 V / 200 mA |
![]() |
E2 set Programmable pulse generation and differential injection |
Up to 2.2 kV adjustable | 1.5 ns rise | Adjustable 1.5 kHz repetition | Both polarities | 50 Mbps optical sensor | TS 23 included; 24 V / 1 A DC |
![]() |
S2 set Transient magnetic-field sensing |
Active + passive H-field probes | 3 MSA 02 heads | Optical signal transfer | MSA 02: 1 AAA battery | SGZ 21 receiver documented; confirm E2 receiver arrangement |
![]() |
P1 set Battery-powered E/H-field injection |
3 generators: P11 + P12 + P21 | Approx. 1 mT H-field / 100 kV/m E-field | Single pulse or 5 kHz | 1.5 V AAA | 1.5 V AAA supply; single pulse / 5 kHz |
![]() |
P23 set Fine-tip capacitive pulse injection |
1.2 kV generator voltage | 10 pF coupling | 1.8-10 ns rise | Single pulse or 5 kHz | 1.5 V AAA | 1.5 V AAA supply; single pulse / 5 kHz |
![]() |
P11t set TTL-synchronized magnetic pulse injection |
Approx. 1 mT | 5 V TTL SMB trigger | Single pulse to 10 kHz | 3 us trigger delay | 6.5-15 V supply | 6.5-15 V supply; power supply included |
![]() |
P12t set TTL-synchronized clamp-style magnetic coupling |
Approx. 1 mT | Coupling-clamp tip | 5 V TTL SMB trigger | Single pulse to 10 kHz | 3 us delay | 6.5-15 V supply; power supply included |
![]() |
H2 set External-generator E/H-field coupling |
6 field sources: 3 H + 3 E | Up to 4.4 kV source supply | External EFT/burst generator required | External EFT/burst generator; source limit 4.4 kV |
![]() |
H3 set Extended external-generator E/H-field coupling |
9 field sources: 4 H + 5 E | High-voltage SMB connections | SHV or Fischer cable choice | External generator required | External EFT/burst generator; observe each source rating |
![]() |
PT4 set Potential-free pulse injection plus E/H-field coupling |
4.5 kV maximum burst input | 1:1 transformer | 500 V output dielectric strength | H- and E-field sources | External EFT/burst generator; transformer maximum 4.5 kV |
![]() |
H4-IC set Small-area magnetic field coupling |
Up to 200 mT | 2.54 mm2 resolution | 1.8 mm diameter head | 0-66 MHz | 4 kV maximum burst | External EFT/burst generator; 4 kV maximum burst input |
![]() |
H5-IC set Magnetic field coupling with BS 06DU-s |
Up to 150 mT | 5 x 6 mm head | 0-560 MHz | 4 kV maximum burst | 15 g source | External EFT/burst generator; 4 kV maximum burst input |
![]() |
BD 11 Cable-transient detection and event indication |
Adjustable sensitivity | LED + relay + optical outputs | 20 m maximum fiber | 2 AAA batteries | 88 x 85 x 32 mm | Two 1.5 V AAA batteries |