Langer S2 set | Magnetic Field Probe Set for Immunity Analysis

Active + passive H-field probes | 3 MSA 02 heads | Optical signal transfer | MSA 02: 1 AAA battery

S2 adds active and passive magnetic field probes for investigating fast transient fields caused by burst and ESD. The MSA 02 active probe accepts three heads; MS 101 and MS 102U add sensing geometries. Langer recommends S2 with E1 and E2. The supplied S2 sheet describes operation with the SGZ 21 receiver from E1; confirm the receiver arrangement when configuring S2 with E2. S2 is a sensing kit, not a disturbance generator.

S2 set - Datasheet

SPECIFICATIONS

S2 set - Magnetic Field Probe Set for Immunity Analysis

S2 adds active and passive magnetic field probes for investigating fast transient fields caused by burst and ESD. The MSA 02 active probe accepts three heads; MS 101 and MS 102U add sensing geometries. Langer recommends S2 with E1 and E2. The supplied S2 sheet describes operation with the SGZ 21 receiver from E1; confirm the receiver arrangement when configuring S2 with E2. S2 is a sensing kit, not a disturbance generator.

S2 set, Magnetic Field Probes for E1

Features and application benefits

FeatureEngineering benefit / use
Active sensing MSA 02 uses one AAA battery and accepts the included black 05K, white 05R and orange 05U heads.
Passive sensing MS 101 and MS 102U extend the choice of probe geometry for following fast transient magnetic fields.
Receiver configuration The supplied S2 sheet describes the SGZ 21 receiver from E1. The current E2 page also recommends S2; confirm the intended receiver connections when specifying an E2 system.

Technical specifications

ParameterSpecification
Sensor types MSA 02 active; MS 101 and MS 102U passive magnetic probes
MSA 02 heads 05K black; 05R white; 05U orange
Receiver arrangement SGZ 21 documented in supplied S2 sheet; S2 recommended for E2 on current manufacturer page - confirm configuration
MSA 02 supply One AAA battery

Included components

PhotoQty.ItemFunction / key specifications
MSA 02, Magnetic Field Probe (active) 1x MSA 02 Magnetic Field Probe (active)
Resolution: < 1 mm
05K black, Probe Head for MSA 02 1x 05K black Probe Head for MSA 02
05R white, Probe Head for MSA 02 1x 05R white Probe Head for MSA 02
05U orange, Probe Head for MSA 02 1x 05U orange Probe Head for MSA 02
MS 101, Magnetic Field Probe 1x MS 101 Magnetic Field Probe
Weight: 10 g
MS 102U, Magnetic Field Probe 1x MS 102U Magnetic Field Probe
  1x S2 case System Case
  1x S2 m S2 Set User Manual

Included component specifications

ComponentParameterSpecification
MSA 02 Resolution < 1 mm
MS 101 Weight 10 g

Application and kit views

ImageWhat it shows
Application with Probe MSA 02-05U Application with Probe MSA 02-05U
Application with probe MS 102U Application with probe MS 102U
Sope of delivery Set S2 Sope of delivery Set S2

System requirements and ordering notes

SGZ 21 receiver documented; confirm E2 receiver arrangement. SGZ 21 is not included in S2. Select a suitable observation setup for the transient event.

Recommended products and accessories

PhotoProductSpecifications / purposeOrdering
SGZ 21, Burst Generator SGZ 21 Approx. 0-1500 V; 2 ns rise / 10 ns tail; 12 V / 200 mA supply. SGZ 21 is also included in the complete E1 set. Recommended supporting item; not included unless stated
  Battery AAA 1.5 V AAA battery. Power source for the relevant mini generator or MSA 02; confirm quantity with the quotation. Recommended supporting item; not included unless stated

Datasheets

DocumentPDF
S2 set - Datasheet View PDF

Practical questions

QuestionAnswer
What is this product best suited to? Observe disturbance paths and correlate magnetic transients with a failure.
What supporting equipment is needed? SGZ 21 receiver documented; confirm E2 receiver arrangement. SGZ 21 is not included in S2. Select a suitable observation setup for the transient event.
Does this establish compliance with IEC 61000-4-4 or IEC 61000-4-2? These are development and diagnostic tools. Relating a local disturbance to an EFT/burst or ESD failure helps troubleshooting; formal compliance requires the applicable standardized generator, coupling method, test setup and procedure.

PCB immunity selection guide

Compare generation, coupling and detection tools. The kit pictures identify the complete sets. Product links below use the planned Absolute EMC product pages.

KitProduct / functionKey distinctionRequired pulse source / power
E1 set, Immunity Development System E1 set
Integrated generation and local E/H-field troubleshooting
Approx. 0-1500 V pulses | 2 ns rise / 10 ns tail | 4 H-field + 5 E-field sources | 10 Mbps optical sensor SGZ 21 included; 12 V / 200 mA
E2 set, TS 23 Immunity Development System E2 set
Programmable pulse generation and differential injection
Up to 2.2 kV adjustable | 1.5 ns rise | Adjustable 1.5 kHz repetition | Both polarities | 50 Mbps optical sensor TS 23 included; 24 V / 1 A DC
S2 set, Magnetic Field Probes for E1 S2 set
Transient magnetic-field sensing
Active + passive H-field probes | 3 MSA 02 heads | Optical signal transfer | MSA 02: 1 AAA battery SGZ 21 receiver documented; confirm E2 receiver arrangement
P1 set, Mini Burst Field Generators P1 set
Battery-powered E/H-field injection
3 generators: P11 + P12 + P21 | Approx. 1 mT H-field / 100 kV/m E-field | Single pulse or 5 kHz | 1.5 V AAA 1.5 V AAA supply; single pulse / 5 kHz
P23 set, Mini Burst Field Generator (E) P23 set
Fine-tip capacitive pulse injection
1.2 kV generator voltage | 10 pF coupling | 1.8-10 ns rise | Single pulse or 5 kHz | 1.5 V AAA 1.5 V AAA supply; single pulse / 5 kHz
P11t set, Mini Burst Field Generator (B, Trigger) P11t set
TTL-synchronized magnetic pulse injection
Approx. 1 mT | 5 V TTL SMB trigger | Single pulse to 10 kHz | 3 us trigger delay | 6.5-15 V supply 6.5-15 V supply; power supply included
P12t set, Mini Burst Field Generator (B, Trigger) P12t set
TTL-synchronized clamp-style magnetic coupling
Approx. 1 mT | Coupling-clamp tip | 5 V TTL SMB trigger | Single pulse to 10 kHz | 3 us delay 6.5-15 V supply; power supply included
H2 set, Field Sources H2 set
External-generator E/H-field coupling
6 field sources: 3 H + 3 E | Up to 4.4 kV source supply | External EFT/burst generator required External EFT/burst generator; source limit 4.4 kV
H3 set, Field Sources H3 set
Extended external-generator E/H-field coupling
9 field sources: 4 H + 5 E | High-voltage SMB connections | SHV or Fischer cable choice | External generator required External EFT/burst generator; observe each source rating
PT4 set, EFT Generator Set PT4 set
Potential-free pulse injection plus E/H-field coupling
4.5 kV maximum burst input | 1:1 transformer | 500 V output dielectric strength | H- and E-field sources External EFT/burst generator; transformer maximum 4.5 kV
H4-IC set, EFT/Burst Magnetic Field Source H4-IC set
Small-area magnetic field coupling
Up to 200 mT | 2.54 mm2 resolution | 1.8 mm diameter head | 0-66 MHz | 4 kV maximum burst External EFT/burst generator; 4 kV maximum burst input
H5-IC set, EFT/Burst Magnetic Field Source H5-IC set
Magnetic field coupling with BS 06DU-s
Up to 150 mT | 5 x 6 mm head | 0-560 MHz | 4 kV maximum burst | 15 g source External EFT/burst generator; 4 kV maximum burst input
BD 11, H-Field Burst Detector BD 11
Cable-transient detection and event indication
Adjustable sensitivity | LED + relay + optical outputs | 20 m maximum fiber | 2 AAA batteries | 88 x 85 x 32 mm Two 1.5 V AAA batteries