IP4B - EFT/Burst Capacitive Coupling Clamp

Capacitive EFT/burst injection for signal and data cables.

The Haefely IP4B couples electrical fast transient and burst pulses onto cables connected to peripheral equipment for IEC/EN 61000-4-4 testing. Its 1 m active coupling length accommodates cable diameters from 4 to 40 mm according to the V2026.06 datasheet. Coupling is capacitive, so the injected disturbance depends on the cable and its placement..

IP4B Datasheet V2026.06

SPECIFICATIONS

HAEFELY EMC ACCESSORIES

IP4B - EFT/Burst Capacitive Coupling Clamp

Capacitive EFT/burst injection for signal and data cables.

IP4B EFT/Burst Capacitive Coupling Clamp - view 1

Overview and application

The Haefely IP4B couples electrical fast transient and burst pulses onto cables connected to peripheral equipment for IEC/EN 61000-4-4 testing. Its 1 m active coupling length accommodates cable diameters from 4 to 40 mm according to the V2026.06 datasheet. Coupling is capacitive, so the injected disturbance depends on the cable and its placement.

  • Injects EFT/burst without a direct conductive connection to each signal conductor.
  • Use a compatible EFT/burst generator and the standard-specified cable arrangement and reference ground plane.
  • For verification, Haefely lists the EFT/Burst Verification Set, PAT 50A, PAT 1000 and a transducer plate as separate accessories.
The manufacturer webpage lists 0.1-40 mm cable diameter, while the newer V2026.06 datasheet specifies 4-40 mm. The datasheet value is used here; confirm use below 4 mm.

Technical specifications

SpecificationDetails
Test method Capacitive injection of EFT/burst pulses
Applicable standard IEC/EN 61000-4-4 Edition 3
Active coupling length 1 m
Cable diameter 4-40 mm (V2026.06 datasheet)
Typical coupling capacitance 100 pF; depends on cable type, diameter, shielding and arrangement
Primary application Signal and data cables; connections to peripheral equipment
AC/DC power-line use Capacitive injection where no appropriate decoupling network is available, as described in the manufacturer datasheet
Dimensions, weight and maximum pulse voltage Not specified in the current datasheet; confirm for the intended generator and setup

Included components

  • IP4B capacitive coupling clamp
  • Fischer/SHV connecting cable
  • Calibration certificate

Generator, EUT, auxiliary equipment and other coupling/decoupling networks are separate system equipment unless explicitly included above.

Standards and system configuration

  • IEC/EN 61000-4-4

Related test equipment

Haefely AXOS 5 immunity test system

AXOS 5

Select the installed EFT/burst or surge module required for the test. AXOS 5 does not provide ring wave or telecom wave.

Haefely AXOS 8 immunity test system

AXOS 8

Configure the required surge, ring-wave, telecom-wave or EFT/burst modules. Stay within the accessory voltage and current ratings.

Documentation

IP4B datasheet - V2026.06

Manufacturer product information

OTHER PRODUCTS IN THE SAME CATEGORY: