3 generators: P11 + P12 + P21 | Approx. 1 mT H-field / 100 kV/m E-field | Single pulse or 5 kHz | 1.5 V AAA
P1 supplies three handheld mini burst field generators for rapid PCB immunity troubleshooting: P11 and P12 for magnetic coupling and P21 for electric coupling. Move the tip close to traces, ground structures or IC regions to locate susceptibility. Separate E- and H-field tools help identify which coupling mechanism deserves attention before changing the design.
MARKETS:
CATEGORIES:
TEST STANDARDS:
P1 supplies three handheld mini burst field generators for rapid PCB immunity troubleshooting: P11 and P12 for magnetic coupling and P21 for electric coupling. Move the tip close to traces, ground structures or IC regions to locate susceptibility. Separate E- and H-field tools help identify which coupling mechanism deserves attention before changing the design.
| Feature | Engineering benefit / use |
|---|---|
| Separate mechanisms | P11 and P12 provide magnetic coupling; P21 provides electric coupling. Compare the circuit response to each mechanism before choosing countermeasures. |
| Portable operation | The mini generators use a 1.5 V AAA supply. The set specification lists single-pulse or 5 kHz operation. |
| Local troubleshooting | Scan close to PCB structures and observe functional errors; use repeated positioning to compare design changes. |
| Parameter | Specification |
|---|---|
| Generated E-field strength | ca. 100 kV/m |
| Generated magnetic flux density | ca. 1 mT |
| Pulse parameter / Frequency | single / 5 kHz |
| Pulse parameter / Supply voltage | 1.5 V / AAA |
| Component | Parameter | Specification |
|---|---|---|
| P11 | Generated magnetic flux density | ca. 1 mT |
| P11 | Pulse parameter / Pulse width | 2 ns ... 8 ns |
| P11 | Pulse parameter / Frequency | single / 5 kHz |
| P11 | Pulse parameter / Polarity | switchable |
| P11 | Pulse parameter / Supply voltage | 1.5 V / AAA |
| P11 | Pulse parameter / Weight | 30 g |
| P11 | Pulse parameter / Sizes (L x W x H) | (118 x 24 x 13) mm |
| P12 | Generated magnetic flux density | ca. 1 mT |
| P12 | Pulse parameter / Pulse width | 2 ns ... 8 ns |
| P12 | Pulse parameter / Frequency | single / 5 kHz |
| P12 | Pulse parameter / Polarity | switchable |
| P12 | Pulse parameter / Supply voltage | 1.5 V / AAA |
| P12 | Pulse parameter / Weight | 30 g |
| P12 | Pulse parameter / Sizes (L x W x H) | (118 x 24 x 13) mm |
| P21 | Generated E-field strength | ca. 100 kV/m |
| P21 | Pulse parameter / Rise time | 1.8 ns ... 10 ns |
| P21 | Pulse parameter / Frequency | single / 5 kHz |
| P21 | Pulse parameter / Polarity | switchable |
| P21 | Pulse parameter / Supply voltage | 1.5 V / AAA |
| P21 | Pulse parameter / Weight | 30 g |
| P21 | Pulse parameter / Sizes (L x W x H) | (118 x 24 x 13) mm |
1.5 V AAA supply; single pulse / 5 kHz. A powered DUT and a way to observe its functional response are required. The tools support engineering diagnosis; they do not replace the complete standardized compliance test setup.
| Photo | Product | Specifications / purpose | Ordering |
|---|---|---|---|
| Battery AAA | 1.5 V AAA battery. Power source for the relevant mini generator or MSA 02; confirm quantity with the quotation. | Recommended supporting item; not included unless stated |
| Document | |
|---|---|
| P1 set - Datasheet | View PDF |
| Question | Answer |
|---|---|
| What is this product best suited to? | Choose a portable three-generator starter kit for local susceptibility searches. |
| What supporting equipment is needed? | 1.5 V AAA supply; single pulse / 5 kHz. A powered DUT and a way to observe its functional response are required. The tools support engineering diagnosis; they do not replace the complete standardized compliance test setup. |
| Does this establish compliance with IEC 61000-4-4 or IEC 61000-4-2? | These are development and diagnostic tools. Relating a local disturbance to an EFT/burst or ESD failure helps troubleshooting; formal compliance requires the applicable standardized generator, coupling method, test setup and procedure. |
Compare generation, coupling and detection tools. The kit pictures identify the complete sets. Product links below use the planned Absolute EMC product pages.
| Kit | Product / function | Key distinction | Required pulse source / power |
|---|---|---|---|
![]() |
E1 set Integrated generation and local E/H-field troubleshooting |
Approx. 0-1500 V pulses | 2 ns rise / 10 ns tail | 4 H-field + 5 E-field sources | 10 Mbps optical sensor | SGZ 21 included; 12 V / 200 mA |
![]() |
E2 set Programmable pulse generation and differential injection |
Up to 2.2 kV adjustable | 1.5 ns rise | Adjustable 1.5 kHz repetition | Both polarities | 50 Mbps optical sensor | TS 23 included; 24 V / 1 A DC |
![]() |
S2 set Transient magnetic-field sensing |
Active + passive H-field probes | 3 MSA 02 heads | Optical signal transfer | MSA 02: 1 AAA battery | SGZ 21 receiver documented; confirm E2 receiver arrangement |
![]() |
P1 set Battery-powered E/H-field injection |
3 generators: P11 + P12 + P21 | Approx. 1 mT H-field / 100 kV/m E-field | Single pulse or 5 kHz | 1.5 V AAA | 1.5 V AAA supply; single pulse / 5 kHz |
![]() |
P23 set Fine-tip capacitive pulse injection |
1.2 kV generator voltage | 10 pF coupling | 1.8-10 ns rise | Single pulse or 5 kHz | 1.5 V AAA | 1.5 V AAA supply; single pulse / 5 kHz |
![]() |
P11t set TTL-synchronized magnetic pulse injection |
Approx. 1 mT | 5 V TTL SMB trigger | Single pulse to 10 kHz | 3 us trigger delay | 6.5-15 V supply | 6.5-15 V supply; power supply included |
![]() |
P12t set TTL-synchronized clamp-style magnetic coupling |
Approx. 1 mT | Coupling-clamp tip | 5 V TTL SMB trigger | Single pulse to 10 kHz | 3 us delay | 6.5-15 V supply; power supply included |
![]() |
H2 set External-generator E/H-field coupling |
6 field sources: 3 H + 3 E | Up to 4.4 kV source supply | External EFT/burst generator required | External EFT/burst generator; source limit 4.4 kV |
![]() |
H3 set Extended external-generator E/H-field coupling |
9 field sources: 4 H + 5 E | High-voltage SMB connections | SHV or Fischer cable choice | External generator required | External EFT/burst generator; observe each source rating |
![]() |
PT4 set Potential-free pulse injection plus E/H-field coupling |
4.5 kV maximum burst input | 1:1 transformer | 500 V output dielectric strength | H- and E-field sources | External EFT/burst generator; transformer maximum 4.5 kV |
![]() |
H4-IC set Small-area magnetic field coupling |
Up to 200 mT | 2.54 mm2 resolution | 1.8 mm diameter head | 0-66 MHz | 4 kV maximum burst | External EFT/burst generator; 4 kV maximum burst input |
![]() |
H5-IC set Magnetic field coupling with BS 06DU-s |
Up to 150 mT | 5 x 6 mm head | 0-560 MHz | 4 kV maximum burst | 15 g source | External EFT/burst generator; 4 kV maximum burst input |
![]() |
BD 11 Cable-transient detection and event indication |
Adjustable sensitivity | LED + relay + optical outputs | 20 m maximum fiber | 2 AAA batteries | 88 x 85 x 32 mm | Two 1.5 V AAA batteries |