Up to 200 mT | 2.54 mm2 resolution | 1.8 mm diameter head | 0-66 MHz | 4 kV maximum burst
H4-IC supplies the BS 06DB-s source for concentrated magnetic EFT/burst coupling into ICs and small PCB regions. The source can be positioned by hand or mounted in a scanner. The set includes a high-voltage connection cable, case and manual; a compatible EFT/burst generator is required separately. Select the required SHV or Fischer cable connector.
MARKETS:
CATEGORIES:
TEST STANDARDS:
Select Options/Sizes:
H4-IC supplies the BS 06DB-s source for concentrated magnetic EFT/burst coupling into ICs and small PCB regions. The source can be positioned by hand or mounted in a scanner. The set includes a high-voltage connection cable, case and manual; a compatible EFT/burst generator is required separately. Select the required SHV or Fischer cable connector.
| Feature | Engineering benefit / use |
|---|---|
| Concentrated field | BS 06DB-s is specified for up to 200 mT, 2.54 mm2 spatial resolution and a 1.8 mm diameter head. |
| Positioning | The source supports handheld use or installation in a scanner; positioning equipment is not listed as included. |
| Current-to-field factor | Published magnetic flux density is 2.37 mT/A. Field strength depends on generator current and the actual setup. |
| Parameter | Specification |
|---|---|
| BS 06DB-s EFT/Burst Magnetic Field Source / Frequency range | 0...66 MHz |
| BS 06DB-s EFT/Burst Magnetic Field Source / Resolution | 2.54 mm2 |
| BS 06DB-s EFT/Burst Magnetic Field Source / Generated magnetic flux density | 2.37 mT/A |
| BS 06DB-s EFT/Burst Magnetic Field Source / Probe head dimensions | diameter 1.8 mm |
| BS 06DB-s EFT/Burst Magnetic Field Source / Max. generated magnetic flux density | 200 mT |
| BS 06DB-s EFT/Burst Magnetic Field Source / Connector - output | SMB, female, jack |
| BS 06DB-s EFT/Burst Magnetic Field Source / Max. Burst-voltage | 4 kV |
| Component | Parameter | Specification |
|---|---|---|
| BS 06DB-s | Frequency range | 0...66 MHz |
| BS 06DB-s | Resolution | 2.54 mm2 |
| BS 06DB-s | Probe head dimensions | diameter 1.8 mm |
| BS 06DB-s | Generated magnetic flux density | 2.37 mT / A |
| BS 06DB-s | Shape | IEC 61000-4-4 |
| BS 06DB-s | Max. generated magnetic flux density | 200 mT |
| BS 06DB-s | Connector - output | SMB, female, jack |
| BS 06DB-s | Weight | 15 g |
| BS 06DB-s | Sizes (L x W x H) | (140 x 8 x 8) mm |
| HV SHV-SMB 1 m | Max. Burst-voltage | 4,4 kV |
| HV SHV-SMB 1 m | Sizes (L x W x H) | 1,20 m |
| Image | What it shows |
|---|---|
![]() |
Application with BS 06DB-s |
![]() |
Fischer connector and SHV connector |
![]() |
Scope of delivery with BS 06DB-s and HV SHV-SMB 1 m cable |
![]() |
Scope of delivery with BS 06DB-s and HV FI-SMB 1 m cable |
External EFT/burst generator; 4 kV maximum burst input. The pulse generator and DUT are not included. Match the cable to the generator and observe the lowest voltage rating of every connected component.
Choose HV SHV-SMB 1 m or HV FI-SMB 1 m as the connection cable. You may order both when you need SHV and Fischer connections. Both cables are not automatically included; confirm the selected configuration and price in the quotation.
| Document | |
|---|---|
| H4-IC set - Datasheet | View PDF |
| Question | Answer |
|---|---|
| What is this product best suited to? | Concentrate a magnetic disturbance into a small IC area. |
| What supporting equipment is needed? | External EFT/burst generator; 4 kV maximum burst input. The pulse generator and DUT are not included. Match the cable to the generator and observe the lowest voltage rating of every connected component. |
| Does this establish compliance with IEC 61000-4-4 or IEC 61000-4-2? | These are development and diagnostic tools. Relating a local disturbance to an EFT/burst or ESD failure helps troubleshooting; formal compliance requires the applicable standardized generator, coupling method, test setup and procedure. |
Compare generation, coupling and detection tools. The kit pictures identify the complete sets. Product links below use the planned Absolute EMC product pages.
| Kit | Product / function | Key distinction | Required pulse source / power |
|---|---|---|---|
![]() |
E1 set Integrated generation and local E/H-field troubleshooting |
Approx. 0-1500 V pulses | 2 ns rise / 10 ns tail | 4 H-field + 5 E-field sources | 10 Mbps optical sensor | SGZ 21 included; 12 V / 200 mA |
![]() |
E2 set Programmable pulse generation and differential injection |
Up to 2.2 kV adjustable | 1.5 ns rise | Adjustable 1.5 kHz repetition | Both polarities | 50 Mbps optical sensor | TS 23 included; 24 V / 1 A DC |
![]() |
S2 set Transient magnetic-field sensing |
Active + passive H-field probes | 3 MSA 02 heads | Optical signal transfer | MSA 02: 1 AAA battery | SGZ 21 receiver documented; confirm E2 receiver arrangement |
![]() |
P1 set Battery-powered E/H-field injection |
3 generators: P11 + P12 + P21 | Approx. 1 mT H-field / 100 kV/m E-field | Single pulse or 5 kHz | 1.5 V AAA | 1.5 V AAA supply; single pulse / 5 kHz |
![]() |
P23 set Fine-tip capacitive pulse injection |
1.2 kV generator voltage | 10 pF coupling | 1.8-10 ns rise | Single pulse or 5 kHz | 1.5 V AAA | 1.5 V AAA supply; single pulse / 5 kHz |
![]() |
P11t set TTL-synchronized magnetic pulse injection |
Approx. 1 mT | 5 V TTL SMB trigger | Single pulse to 10 kHz | 3 us trigger delay | 6.5-15 V supply | 6.5-15 V supply; power supply included |
![]() |
P12t set TTL-synchronized clamp-style magnetic coupling |
Approx. 1 mT | Coupling-clamp tip | 5 V TTL SMB trigger | Single pulse to 10 kHz | 3 us delay | 6.5-15 V supply; power supply included |
![]() |
H2 set External-generator E/H-field coupling |
6 field sources: 3 H + 3 E | Up to 4.4 kV source supply | External EFT/burst generator required | External EFT/burst generator; source limit 4.4 kV |
![]() |
H3 set Extended external-generator E/H-field coupling |
9 field sources: 4 H + 5 E | High-voltage SMB connections | SHV or Fischer cable choice | External generator required | External EFT/burst generator; observe each source rating |
![]() |
PT4 set Potential-free pulse injection plus E/H-field coupling |
4.5 kV maximum burst input | 1:1 transformer | 500 V output dielectric strength | H- and E-field sources | External EFT/burst generator; transformer maximum 4.5 kV |
![]() |
H4-IC set Small-area magnetic field coupling |
Up to 200 mT | 2.54 mm2 resolution | 1.8 mm diameter head | 0-66 MHz | 4 kV maximum burst | External EFT/burst generator; 4 kV maximum burst input |
![]() |
H5-IC set Magnetic field coupling with BS 06DU-s |
Up to 150 mT | 5 x 6 mm head | 0-560 MHz | 4 kV maximum burst | 15 g source | External EFT/burst generator; 4 kV maximum burst input |
![]() |
BD 11 Cable-transient detection and event indication |
Adjustable sensitivity | LED + relay + optical outputs | 20 m maximum fiber | 2 AAA batteries | 88 x 85 x 32 mm | Two 1.5 V AAA batteries |