Adjustable sensitivity | LED + relay + optical outputs | 20 m maximum fiber | 2 AAA batteries | 88 x 85 x 32 mm
BD 11 detects the magnetic field associated with burst or ESD current pulses in a cable. It helps correlate intermittent system errors with a transient disturbance. An LED provides local indication, while a potential-free relay and optical output support external event recording. Adjustable sensitivity and memory help capture sporadic events. BD 11 is a detector, not a burst generator.
MARKETS:
CATEGORIES:
TEST STANDARDS:
BD 11 detects the magnetic field associated with burst or ESD current pulses in a cable. It helps correlate intermittent system errors with a transient disturbance. An LED provides local indication, while a potential-free relay and optical output support external event recording. Adjustable sensitivity and memory help capture sporadic events. BD 11 is a detector, not a burst generator.
| Feature | Engineering benefit / use |
|---|---|
| Capture intermittent events | Adjust sensitivity to the application, position the detector at the cable, and use event memory to help identify sporadic disturbances. |
| Three indication paths | An LED provides local indication; a potential-free relay and optical output allow an external instrument to record the event. |
| Output pulse | The literature gives an approximately 100 ms indication/output pulse. This is not the rise time or width of the original EFT/ESD current transient. |
| Relay limits | Maximum switching voltage is 125 V and maximum switching current is 1 A. Do not interpret these as detector input ratings or a 125 W switching guarantee. |
| Parameter | Specification |
|---|---|
| Optical fibre connector | 2.2 mm diameter |
| Supply voltage | 2 x 1.5 V AAA battery |
| Max. switching voltage | 125 V |
| Max. switching current | 1 A |
| Max. optical fibre length | 20 m |
| Sizes (L x W x H) | (88 x 85 x 32) mm |
| Detection | Magnetic field from burst/ESD current pulses in a cable |
| Sensitivity | Continuously adjustable |
| Indication | LED; potential-free relay; optical output; memory |
| Indication pulse duration | Approx. 100 ms (not disturbance pulse duration) |
| Image | What it shows |
|---|---|
![]() |
Application BD 11 with cable |
Two 1.5 V AAA batteries. External event-recording equipment and optical fiber are not specified as included. Use the indication outputs within their ratings.
| Document | |
|---|---|
| BD 11 - Datasheet | View PDF |
| Question | Answer |
|---|---|
| Does BD 11 generate a burst pulse? | No. It detects magnetic fields associated with cable-current transients and produces event indications. |
| Is 125 V a cable measurement limit? | No. The published 125 V value is the maximum relay switching voltage; the 1 A value is the maximum switching current. |
| Does it show the original transient waveform? | It provides detection/indication signals and memory. The approximate 100 ms output duration is not a measurement of the original EFT or ESD waveform. |
Compare generation, coupling and detection tools. The kit pictures identify the complete sets. Product links below use the planned Absolute EMC product pages.
| Kit | Product / function | Key distinction | Required pulse source / power |
|---|---|---|---|
![]() |
E1 set Integrated generation and local E/H-field troubleshooting |
Approx. 0-1500 V pulses | 2 ns rise / 10 ns tail | 4 H-field + 5 E-field sources | 10 Mbps optical sensor | SGZ 21 included; 12 V / 200 mA |
![]() |
E2 set Programmable pulse generation and differential injection |
Up to 2.2 kV adjustable | 1.5 ns rise | Adjustable 1.5 kHz repetition | Both polarities | 50 Mbps optical sensor | TS 23 included; 24 V / 1 A DC |
![]() |
S2 set Transient magnetic-field sensing |
Active + passive H-field probes | 3 MSA 02 heads | Optical signal transfer | MSA 02: 1 AAA battery | SGZ 21 receiver documented; confirm E2 receiver arrangement |
![]() |
P1 set Battery-powered E/H-field injection |
3 generators: P11 + P12 + P21 | Approx. 1 mT H-field / 100 kV/m E-field | Single pulse or 5 kHz | 1.5 V AAA | 1.5 V AAA supply; single pulse / 5 kHz |
![]() |
P23 set Fine-tip capacitive pulse injection |
1.2 kV generator voltage | 10 pF coupling | 1.8-10 ns rise | Single pulse or 5 kHz | 1.5 V AAA | 1.5 V AAA supply; single pulse / 5 kHz |
![]() |
P11t set TTL-synchronized magnetic pulse injection |
Approx. 1 mT | 5 V TTL SMB trigger | Single pulse to 10 kHz | 3 us trigger delay | 6.5-15 V supply | 6.5-15 V supply; power supply included |
![]() |
P12t set TTL-synchronized clamp-style magnetic coupling |
Approx. 1 mT | Coupling-clamp tip | 5 V TTL SMB trigger | Single pulse to 10 kHz | 3 us delay | 6.5-15 V supply; power supply included |
![]() |
H2 set External-generator E/H-field coupling |
6 field sources: 3 H + 3 E | Up to 4.4 kV source supply | External EFT/burst generator required | External EFT/burst generator; source limit 4.4 kV |
![]() |
H3 set Extended external-generator E/H-field coupling |
9 field sources: 4 H + 5 E | High-voltage SMB connections | SHV or Fischer cable choice | External generator required | External EFT/burst generator; observe each source rating |
![]() |
PT4 set Potential-free pulse injection plus E/H-field coupling |
4.5 kV maximum burst input | 1:1 transformer | 500 V output dielectric strength | H- and E-field sources | External EFT/burst generator; transformer maximum 4.5 kV |
![]() |
H4-IC set Small-area magnetic field coupling |
Up to 200 mT | 2.54 mm2 resolution | 1.8 mm diameter head | 0-66 MHz | 4 kV maximum burst | External EFT/burst generator; 4 kV maximum burst input |
![]() |
H5-IC set Magnetic field coupling with BS 06DU-s |
Up to 150 mT | 5 x 6 mm head | 0-560 MHz | 4 kV maximum burst | 15 g source | External EFT/burst generator; 4 kV maximum burst input |
![]() |
BD 11 Cable-transient detection and event indication |
Adjustable sensitivity | LED + relay + optical outputs | 20 m maximum fiber | 2 AAA batteries | 88 x 85 x 32 mm | Two 1.5 V AAA batteries |