Langer P23 set | Mini Burst E-Field Generator Set

1.2 kV generator voltage | 10 pF coupling | 1.8-10 ns rise | Single pulse or 5 kHz | 1.5 V AAA

P23 targets digital input nodes such as reset, clock and crystal connections. Its fine tip contacts the selected pin or trace; the disturbance is capacitively coupled inside the generator. This gives a localized way to investigate sensitive input structures that may be difficult to isolate with a larger field source. The set includes the P23 generator, A6 case and manual.

P23 set - Datasheet

SPECIFICATIONS

P23 set - Mini Burst E-Field Generator Set

P23 targets digital input nodes such as reset, clock and crystal connections. Its fine tip contacts the selected pin or trace; the disturbance is capacitively coupled inside the generator. This gives a localized way to investigate sensitive input structures that may be difficult to isolate with a larger field source. The set includes the P23 generator, A6 case and manual.

P23 set, Mini Burst Field Generator (E)

Features and application benefits

FeatureEngineering benefit / use
Fine structures The thin tip is positioned directly on the IC pin or signal trace. Internal capacitive coupling applies the pulse to that selected node.
Typical nodes Reset, clock, crystal connections and other digital input lines are typical investigation points.
Pulse specification Generator voltage is 1.2 kV with 10 pF coupling and a specified rise-time range of 1.8-10 ns. Actual node stress depends on the DUT.

Technical specifications

ParameterSpecification
Generator voltage 1.2 kV
Coupling capacity 10 pF
Pulse parameter / Rise time 1.8 ns ... 10 ns
Pulse parameter / Frequency single / 5 kHz
Pulse parameter / Supply voltage 1.5 V / AAA

Included components

PhotoQty.ItemFunction / key specifications
P23, Mini Burst Field Generator (E) 1x P23 Mini Burst Field Generator (E)
Generator voltage: 1.2 kV
Coupling capacity: 10 pF
Pulse parameter / Rise time: 1.8 ns ... 10 ns
Pulse parameter / Frequency: single / 5 kHz
  1x A6 case System case
  1x P23 m P23 Set User Manual

Included component specifications

ComponentParameterSpecification
P23 Generator voltage 1.2 kV
P23 Coupling capacity 10 pF
P23 Pulse parameter / Rise time 1.8 ns ... 10 ns
P23 Pulse parameter / Frequency single / 5 kHz
P23 Pulse parameter / Polarity switchable
P23 Pulse parameter / Supply voltage 1.5 V / AAA
P23 Pulse parameter / Weight 30 g
P23 Pulse parameter / Sizes (L x W x H) (118 x 24 x 13) mm

System requirements and ordering notes

1.5 V AAA supply; single pulse / 5 kHz. A powered DUT and a way to observe its functional response are required. The tools support engineering diagnosis; they do not replace the complete standardized compliance test setup.

Recommended products and accessories

PhotoProductSpecifications / purposeOrdering
  Battery AAA 1.5 V AAA battery. Power source for the relevant mini generator or MSA 02; confirm quantity with the quotation. Recommended supporting item; not included unless stated

Datasheets

DocumentPDF
P23 set - Datasheet View PDF

Practical questions

QuestionAnswer
What is this product best suited to? Investigate individual digital input pins or fine signal structures.
What supporting equipment is needed? 1.5 V AAA supply; single pulse / 5 kHz. A powered DUT and a way to observe its functional response are required. The tools support engineering diagnosis; they do not replace the complete standardized compliance test setup.
Does this establish compliance with IEC 61000-4-4 or IEC 61000-4-2? These are development and diagnostic tools. Relating a local disturbance to an EFT/burst or ESD failure helps troubleshooting; formal compliance requires the applicable standardized generator, coupling method, test setup and procedure.

PCB immunity selection guide

Compare generation, coupling and detection tools. The kit pictures identify the complete sets. Product links below use the planned Absolute EMC product pages.

KitProduct / functionKey distinctionRequired pulse source / power
E1 set, Immunity Development System E1 set
Integrated generation and local E/H-field troubleshooting
Approx. 0-1500 V pulses | 2 ns rise / 10 ns tail | 4 H-field + 5 E-field sources | 10 Mbps optical sensor SGZ 21 included; 12 V / 200 mA
E2 set, TS 23 Immunity Development System E2 set
Programmable pulse generation and differential injection
Up to 2.2 kV adjustable | 1.5 ns rise | Adjustable 1.5 kHz repetition | Both polarities | 50 Mbps optical sensor TS 23 included; 24 V / 1 A DC
S2 set, Magnetic Field Probes for E1 S2 set
Transient magnetic-field sensing
Active + passive H-field probes | 3 MSA 02 heads | Optical signal transfer | MSA 02: 1 AAA battery SGZ 21 receiver documented; confirm E2 receiver arrangement
P1 set, Mini Burst Field Generators P1 set
Battery-powered E/H-field injection
3 generators: P11 + P12 + P21 | Approx. 1 mT H-field / 100 kV/m E-field | Single pulse or 5 kHz | 1.5 V AAA 1.5 V AAA supply; single pulse / 5 kHz
P23 set, Mini Burst Field Generator (E) P23 set
Fine-tip capacitive pulse injection
1.2 kV generator voltage | 10 pF coupling | 1.8-10 ns rise | Single pulse or 5 kHz | 1.5 V AAA 1.5 V AAA supply; single pulse / 5 kHz
P11t set, Mini Burst Field Generator (B, Trigger) P11t set
TTL-synchronized magnetic pulse injection
Approx. 1 mT | 5 V TTL SMB trigger | Single pulse to 10 kHz | 3 us trigger delay | 6.5-15 V supply 6.5-15 V supply; power supply included
P12t set, Mini Burst Field Generator (B, Trigger) P12t set
TTL-synchronized clamp-style magnetic coupling
Approx. 1 mT | Coupling-clamp tip | 5 V TTL SMB trigger | Single pulse to 10 kHz | 3 us delay 6.5-15 V supply; power supply included
H2 set, Field Sources H2 set
External-generator E/H-field coupling
6 field sources: 3 H + 3 E | Up to 4.4 kV source supply | External EFT/burst generator required External EFT/burst generator; source limit 4.4 kV
H3 set, Field Sources H3 set
Extended external-generator E/H-field coupling
9 field sources: 4 H + 5 E | High-voltage SMB connections | SHV or Fischer cable choice | External generator required External EFT/burst generator; observe each source rating
PT4 set, EFT Generator Set PT4 set
Potential-free pulse injection plus E/H-field coupling
4.5 kV maximum burst input | 1:1 transformer | 500 V output dielectric strength | H- and E-field sources External EFT/burst generator; transformer maximum 4.5 kV
H4-IC set, EFT/Burst Magnetic Field Source H4-IC set
Small-area magnetic field coupling
Up to 200 mT | 2.54 mm2 resolution | 1.8 mm diameter head | 0-66 MHz | 4 kV maximum burst External EFT/burst generator; 4 kV maximum burst input
H5-IC set, EFT/Burst Magnetic Field Source H5-IC set
Magnetic field coupling with BS 06DU-s
Up to 150 mT | 5 x 6 mm head | 0-560 MHz | 4 kV maximum burst | 15 g source External EFT/burst generator; 4 kV maximum burst input
BD 11, H-Field Burst Detector BD 11
Cable-transient detection and event indication
Adjustable sensitivity | LED + relay + optical outputs | 20 m maximum fiber | 2 AAA batteries | 88 x 85 x 32 mm Two 1.5 V AAA batteries
OTHER PRODUCTS IN THE SAME CATEGORY:
Loading...