4.5 kV maximum burst input | 1:1 transformer | 500 V output dielectric strength | H- and E-field sources
PT4 adds potential-free burst pulse injection to an existing EFT/burst generator. Its 1:1 transformer couples disturbances into selected circuit sections, while the included BS 04DB-h and ES 05D-h sources support localized magnetic and electric field scans. Match both the transformer and cable connector to the generator when ordering.
MARKETS:
CATEGORIES:
TEST STANDARDS:
Select Options/Sizes:
PT4 adds potential-free burst pulse injection to an existing EFT/burst generator. Its 1:1 transformer couples disturbances into selected circuit sections, while the included BS 04DB-h and ES 05D-h sources support localized magnetic and electric field scans. Match both the transformer and cable connector to the generator when ordering.
| Feature | Engineering benefit / use |
|---|---|
| Floating injection | The PT4 transformer converts generator pulses into potential-free burst pulses for injection into selected DUT sections. |
| Two additional coupling methods | BS 04DB-h and ES 05D-h add magnetic and electric field injection to the transformer method. |
| Ratings remain separate | The transformer has a 4.5 kV maximum burst voltage and a 500 V output dielectric-strength specification. These are different limits and are not continuous DUT supply ratings. |
| Parameter | Specification |
|---|---|
| PT4 Burst Transformer / Max. burst voltage | 4.5 kV |
| PT4 Burst Transformer / Transformation ratio | 1:1 |
| PT4 Burst Transformer / Dielectric strength of outputs | 500 V / DC, AC 50 Hz |
| Component | Parameter | Specification |
|---|---|---|
| PT4 | Max. Burst-voltage | 4,5 kV |
| PT4 | Transformation ratio | 1:1 |
| PT4 | Dielectric strength of outputs | 500 V / DC, AC 50 Hz |
| PT4 | Connector - output | SHV-BNC |
| BS 04DB-h | Probe head dimensions | 1 mm - 3 mm |
| HV SHV-SMB 1 m | Max. Burst-voltage | 4,4 kV |
| HV SHV-SMB 1 m | Sizes (L x W x H) | 1,20 m |
| Image | What it shows |
|---|---|
![]() |
Application PT4 set |
![]() |
Scope of delivery PT4 set |
External EFT/burst generator; transformer maximum 4.5 kV. The pulse generator and DUT are not included. Match the cable to the generator and observe the lowest voltage rating of every connected component.
| Photo | Product | Specifications / purpose | Ordering |
|---|---|---|---|
![]() |
H3 set | 9 field sources: 4 magnetic + 5 electric. Requires an external EFT/burst generator. | Optional complete set; not included |
![]() |
HV SHV-SMB 1 m | 1 m purpose-built high-voltage cable; SHV generator-side connector to high-voltage-resistant SMB. Select the connector to match the generator. | Choose as the set cable, or add alongside the other cable |
![]() |
HV FI-SMB 1 m | 1 m purpose-built high-voltage cable; Fischer S103A023 generator-side connector to high-voltage-resistant SMB. Select the connector to match the generator. | Choose as the set cable, or add alongside the other cable |
Choose HV SHV-SMB 1 m or HV FI-SMB 1 m as the connection cable. You may order both when you need SHV and Fischer connections. Both cables are not automatically included; confirm the selected configuration and price in the quotation.
| Document | |
|---|---|
| PT4 set - Datasheet | View PDF |
| Question | Answer |
|---|---|
| What is this product best suited to? | Investigate direct injection paths as well as localized field coupling. |
| What supporting equipment is needed? | External EFT/burst generator; transformer maximum 4.5 kV. The pulse generator and DUT are not included. Match the cable to the generator and observe the lowest voltage rating of every connected component. |
| Does this establish compliance with IEC 61000-4-4 or IEC 61000-4-2? | These are development and diagnostic tools. Relating a local disturbance to an EFT/burst or ESD failure helps troubleshooting; formal compliance requires the applicable standardized generator, coupling method, test setup and procedure. |
Compare generation, coupling and detection tools. The kit pictures identify the complete sets. Product links below use the planned Absolute EMC product pages.
| Kit | Product / function | Key distinction | Required pulse source / power |
|---|---|---|---|
![]() |
E1 set Integrated generation and local E/H-field troubleshooting |
Approx. 0-1500 V pulses | 2 ns rise / 10 ns tail | 4 H-field + 5 E-field sources | 10 Mbps optical sensor | SGZ 21 included; 12 V / 200 mA |
![]() |
E2 set Programmable pulse generation and differential injection |
Up to 2.2 kV adjustable | 1.5 ns rise | Adjustable 1.5 kHz repetition | Both polarities | 50 Mbps optical sensor | TS 23 included; 24 V / 1 A DC |
![]() |
S2 set Transient magnetic-field sensing |
Active + passive H-field probes | 3 MSA 02 heads | Optical signal transfer | MSA 02: 1 AAA battery | SGZ 21 receiver documented; confirm E2 receiver arrangement |
![]() |
P1 set Battery-powered E/H-field injection |
3 generators: P11 + P12 + P21 | Approx. 1 mT H-field / 100 kV/m E-field | Single pulse or 5 kHz | 1.5 V AAA | 1.5 V AAA supply; single pulse / 5 kHz |
![]() |
P23 set Fine-tip capacitive pulse injection |
1.2 kV generator voltage | 10 pF coupling | 1.8-10 ns rise | Single pulse or 5 kHz | 1.5 V AAA | 1.5 V AAA supply; single pulse / 5 kHz |
![]() |
P11t set TTL-synchronized magnetic pulse injection |
Approx. 1 mT | 5 V TTL SMB trigger | Single pulse to 10 kHz | 3 us trigger delay | 6.5-15 V supply | 6.5-15 V supply; power supply included |
![]() |
P12t set TTL-synchronized clamp-style magnetic coupling |
Approx. 1 mT | Coupling-clamp tip | 5 V TTL SMB trigger | Single pulse to 10 kHz | 3 us delay | 6.5-15 V supply; power supply included |
![]() |
H2 set External-generator E/H-field coupling |
6 field sources: 3 H + 3 E | Up to 4.4 kV source supply | External EFT/burst generator required | External EFT/burst generator; source limit 4.4 kV |
![]() |
H3 set Extended external-generator E/H-field coupling |
9 field sources: 4 H + 5 E | High-voltage SMB connections | SHV or Fischer cable choice | External generator required | External EFT/burst generator; observe each source rating |
![]() |
PT4 set Potential-free pulse injection plus E/H-field coupling |
4.5 kV maximum burst input | 1:1 transformer | 500 V output dielectric strength | H- and E-field sources | External EFT/burst generator; transformer maximum 4.5 kV |
![]() |
H4-IC set Small-area magnetic field coupling |
Up to 200 mT | 2.54 mm2 resolution | 1.8 mm diameter head | 0-66 MHz | 4 kV maximum burst | External EFT/burst generator; 4 kV maximum burst input |
![]() |
H5-IC set Magnetic field coupling with BS 06DU-s |
Up to 150 mT | 5 x 6 mm head | 0-560 MHz | 4 kV maximum burst | 15 g source | External EFT/burst generator; 4 kV maximum burst input |
![]() |
BD 11 Cable-transient detection and event indication |
Adjustable sensitivity | LED + relay + optical outputs | 20 m maximum fiber | 2 AAA batteries | 88 x 85 x 32 mm | Two 1.5 V AAA batteries |