Approx. 1 mT | 5 V TTL SMB trigger | Single pulse to 10 kHz | 3 us trigger delay | 6.5-15 V supply
P11t produces a localized transient magnetic field that can be synchronized to the DUT or external control logic. A 5 V TTL input lets engineers disturb a circuit at a chosen operating state, rather than relying only on an unsynchronized scan. The set includes the generator, a 1 m SMB-BNC cable, power supply, case and manual.
MARKETS:
CATEGORIES:
TEST STANDARDS:
P11t produces a localized transient magnetic field that can be synchronized to the DUT or external control logic. A 5 V TTL input lets engineers disturb a circuit at a chosen operating state, rather than relying only on an unsynchronized scan. The set includes the generator, a 1 m SMB-BNC cable, power supply, case and manual.
| Feature | Engineering benefit / use |
|---|---|
| Synchronization | A DUT signal or external control logic supplies the 5 V TTL trigger through the SMB input. |
| Timing | Published trigger delay is 3 us. Trigger repetition is specified from single pulse to 10 kHz. |
| Focused diagnosis | Apply the disturbance at a selected operating condition to investigate timing-dependent faults. |
| Parameter | Specification |
|---|---|
| External trigger input | SMB, male, jack; 5 V TTL |
| Generated magnetic flux density | ca. 1 mT |
| Pulse parameter / Frequency | single ... 10 kHz |
| Pulse parameter / Trigger-pulse delay | 3 us |
| Pulse parameter / Supply voltage | 6.5 V ... 15 V |
| Component | Parameter | Specification |
|---|---|---|
| P11t | Generator voltage | 400 V |
| P11t | External trigger input | SMB, male, jack; 5 V TTL |
| P11t | Generated magnetic flux density | ca. 1 mT |
| P11t | Pulse parameter / Pulse width | 2 ns ... 8 ns |
| P11t | Pulse parameter / Frequency | single ... 10 kHz |
| P11t | Pulse parameter / Polarity | switchable |
| P11t | Pulse parameter / Trigger-pulse delay | 3 us |
| P11t | Pulse parameter / Supply voltage | 6.5 V ... 15 V |
| P11t | Pulse parameter / Current input | 50 mA @ 6.5 V |
| P11t | Pulse parameter / Weight | 20 g |
| P11t | Pulse parameter / Sizes (L x W x H) | (125 x 24 x 20) mm |
| SMB-BNC 1 m | Weight | 25 g |
| SMB-BNC 1 m | Sizes (L x W x H) | 1 m |
6.5-15 V supply; power supply included. A powered DUT and a way to observe its functional response are required. The tools support engineering diagnosis; they do not replace the complete standardized compliance test setup.
| Document | |
|---|---|
| P11t set - Datasheet | View PDF |
| Question | Answer |
|---|---|
| What is this product best suited to? | Time the disturbance to a particular circuit operation. |
| What supporting equipment is needed? | 6.5-15 V supply; power supply included. A powered DUT and a way to observe its functional response are required. The tools support engineering diagnosis; they do not replace the complete standardized compliance test setup. |
| Does this establish compliance with IEC 61000-4-4 or IEC 61000-4-2? | These are development and diagnostic tools. Relating a local disturbance to an EFT/burst or ESD failure helps troubleshooting; formal compliance requires the applicable standardized generator, coupling method, test setup and procedure. |
Compare generation, coupling and detection tools. The kit pictures identify the complete sets. Product links below use the planned Absolute EMC product pages.
| Kit | Product / function | Key distinction | Required pulse source / power |
|---|---|---|---|
![]() |
E1 set Integrated generation and local E/H-field troubleshooting |
Approx. 0-1500 V pulses | 2 ns rise / 10 ns tail | 4 H-field + 5 E-field sources | 10 Mbps optical sensor | SGZ 21 included; 12 V / 200 mA |
![]() |
E2 set Programmable pulse generation and differential injection |
Up to 2.2 kV adjustable | 1.5 ns rise | Adjustable 1.5 kHz repetition | Both polarities | 50 Mbps optical sensor | TS 23 included; 24 V / 1 A DC |
![]() |
S2 set Transient magnetic-field sensing |
Active + passive H-field probes | 3 MSA 02 heads | Optical signal transfer | MSA 02: 1 AAA battery | SGZ 21 receiver documented; confirm E2 receiver arrangement |
![]() |
P1 set Battery-powered E/H-field injection |
3 generators: P11 + P12 + P21 | Approx. 1 mT H-field / 100 kV/m E-field | Single pulse or 5 kHz | 1.5 V AAA | 1.5 V AAA supply; single pulse / 5 kHz |
![]() |
P23 set Fine-tip capacitive pulse injection |
1.2 kV generator voltage | 10 pF coupling | 1.8-10 ns rise | Single pulse or 5 kHz | 1.5 V AAA | 1.5 V AAA supply; single pulse / 5 kHz |
![]() |
P11t set TTL-synchronized magnetic pulse injection |
Approx. 1 mT | 5 V TTL SMB trigger | Single pulse to 10 kHz | 3 us trigger delay | 6.5-15 V supply | 6.5-15 V supply; power supply included |
![]() |
P12t set TTL-synchronized clamp-style magnetic coupling |
Approx. 1 mT | Coupling-clamp tip | 5 V TTL SMB trigger | Single pulse to 10 kHz | 3 us delay | 6.5-15 V supply; power supply included |
![]() |
H2 set External-generator E/H-field coupling |
6 field sources: 3 H + 3 E | Up to 4.4 kV source supply | External EFT/burst generator required | External EFT/burst generator; source limit 4.4 kV |
![]() |
H3 set Extended external-generator E/H-field coupling |
9 field sources: 4 H + 5 E | High-voltage SMB connections | SHV or Fischer cable choice | External generator required | External EFT/burst generator; observe each source rating |
![]() |
PT4 set Potential-free pulse injection plus E/H-field coupling |
4.5 kV maximum burst input | 1:1 transformer | 500 V output dielectric strength | H- and E-field sources | External EFT/burst generator; transformer maximum 4.5 kV |
![]() |
H4-IC set Small-area magnetic field coupling |
Up to 200 mT | 2.54 mm2 resolution | 1.8 mm diameter head | 0-66 MHz | 4 kV maximum burst | External EFT/burst generator; 4 kV maximum burst input |
![]() |
H5-IC set Magnetic field coupling with BS 06DU-s |
Up to 150 mT | 5 x 6 mm head | 0-560 MHz | 4 kV maximum burst | 15 g source | External EFT/burst generator; 4 kV maximum burst input |
![]() |
BD 11 Cable-transient detection and event indication |
Adjustable sensitivity | LED + relay + optical outputs | 20 m maximum fiber | 2 AAA batteries | 88 x 85 x 32 mm | Two 1.5 V AAA batteries |