Designed for applying the impulse output voltage of the Combination wave/ Ring wave generator to interconnection lines of the equipment under test, acc. to IEC 61000-4-5, Fig9/ IEC 61000-4-12, Fig. 8.
The coupling/decoupling network CDN 504/ 508 U essentially consists of a current compensated decoupling inductor, L1 – L4/L8, and a set of coupling impedances to be inserted in the coupling path.
PARTNER:
MARKETS:
TEST STANDARDS:
CDN 504U / 508U unsymmetrical
According to |
|
IEC 61000-4-5 |
IEC 61000-4-12 |
Designed for applying the impulse output voltage of the Combination wave/ Ring wave generator to interconnection lines of the equipment under test, acc. to IEC 61000-4-5, Fig9/ IEC 61000-4-12, Fig. 8.
The coupling/decoupling network CDN 504/ 508 U essentially consists of a current compensated decoupling inductor, L1 – L4/L8, and a set of coupling impedances to be inserted in the coupling path.
For surge coupling according to EN / IEC61000-4-5 coupling impedances, 40Ω + 0.5µF and 40Ω + OVP are available. A capacity of >3µF is available for coupling the ring wave signal according to EN / IEC 61000-4-12. A slot to connect your own external coupling impedance is also available.
A coupling impedance is activated by inserting the corresponding bridge.
The coupling is set by inserting the coupling bridges.
Here in the picture as an example EA1-> EA2.
A bridge to connect the COM connection of the generator with GND is also available.
The inputs E1 - E4/ 8 are decoupled by the inductances L1 - L4/8.
The test item is connected to outputs A1 - A4/8.
Technical specification: CDN 504/ 508 U | ||
Rated voltage | 250VAC / 350VDC | |
Rated current | 6A | |
Max. test voltage | 5.0 kV,1.2/50µs,10/700 µs | |
Max. test current | 2,5 kA, 8/20µs | |
Coupling Impedance, selectable: | Surge Couplingacc. IEC 61000-4-5Fig. 9 | 40Ω + 0,5μF |
40Ω + OVP | ||
Ringwave Couplingacc. IEC 61000-4-12Fig. 8 | >3 μF | |
Decoupling inductors, current compensated | L1 – L4 | 20 mH |
Dimensions: 19"-cabinet W * H * D | 450*180*360mm³ | |
Weight | 9.5 kg |
Accessories | CDN 504/ 508 U |
1 HV-IN connecting cable with 4 mmÆ connectors, 1 GND-connecting cable with 4 mmÆ connectors, plugs 19 mm. |